Horário de atendimento: Segunda a sexta, das 9h às 18h.
3VA2216-5MN32-0AA0 - 3VA2216-5MN32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu 55kA @ 415V 3-po..
Em estoque Produto em alta

3VA2216-5MN32-0AA0

3VA2216-5MN32-0AA0 SIEMENS circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu 55kA @ 415V 3-po..

$0.00 USD
3064 em estoque
Especificações principais
: Confirmation
EAN: 4042948830666
EMC: Declaration of Conformity
UPC: 804766433993
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Confirmation
EAN 4042948830666
EMC Declaration of Conformity
UPC 804766433993
ETIM 5
IDEA 4
Width 105 mm
depth 86 mm
Height 181 mm
UNSPSC 14
eClass 6
Group Code P360
Net Weight 2.232 kg
depth [in] 3.39 in
width [in] 4.13 in
height [in] 7.13 in
Date5/4/2022
Metal Factor LOA-----
● at 240 V 85 kA
● at 415 V 55 kA
● at 440 V 55 kA
● at 500 V 36 kA
● at 690 V 3 kA
Product Group 5374
Product class B: return restricted, please contact your Siemens partner/contact
Quantity Unit 1 Piece
● at 40 °C 160 A
● at 45 °C 160 A
● at 50 °C 160 A
● at 55 °C 160 A
● at 60 °C 160 A
● at 65 °C 160 A
● at 70 °C 160 A
Commodity Code 85362090
Product family 3VA Molded Case Circuit Breakers up to 1600 A, IEC
last modified: 10/8/2021
Net Weight (kg) 2,232 Kg
Product version Motor protection
number of poles 3
product function
Country of origin Czech Republic
Marine / Shipping other
product component
LKZ_FDB/ CatalogID LV10.1
Packaging Quantity 1
product brand name SENTRON
● trip indicator No
Packaging Dimension 134,00 x 200,00 x 145,00
Product Description circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=160A overload protection Ir=63A...160A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit
ambient temperature
operational current
product designation Molded case circuit breaker
● voltage trigger No
Product Lifecycle (PLM) PM300:Active Product
Rated voltage (EF003977) ['690', '690']
power loss [W] / maximum 19.7 W
● undervoltage release No
Export Control Regulations AL : N / ECCN : EAR99
Number of poles (EF001391) 3
● communication function No
Standard lead time ex-works 40 Day/Days
Surcharge for Raw Materials None
rated insulation voltage Ui 800 V
● phase failure detection Yes
Package size unit of measure MM
● during storage / maximum 80 °C
● during storage / minimum -40 °C
Courant permanent assigné Iu 160 A
Device construction (EF008240) Built-in device fixed built-in technique
● during operation / maximum 70 °C
● during operation / minimum -25 °C
● other measurement function No
Motor drive optional (EF007386) true
ground-fault monitoring version Without
Motor drive integrated (EF006697) false
design of the overcurrent release ETU350M
Type of control element (EF006976) Rocker lever
protection class IP / on the front IP40
Degree of protection (IP) (EF005474) IP40
operating power / at AC-3 / at 230 V 45 000 W
operating power / at AC-3 / at 400 V 75 000 W
Article Number (Market Facing Number) 3VA2216-5MN32-0AA0
Rated permanent current Iu (EF001389) 160.0
With under voltage release (EF007518) -
WEEE (2012/19/EU) Take-Back Obligation Yes
With switched-off indicator (EF007006) -
reference code / according to IEC 81346-2 Q
product extension / optional / motor drive Yes
Adjustable response value current / li max. 2 400 A
Adjustable response value current / li min. 2 400 A
Overload release current setting (EF002336) ['63', '160']
short-circuit current making capacity (Icm)
Integrated earth fault protection (EF007296) false
Neutral conductors / upgradeable/retrofittable No
number of CO contacts / for auxiliary contacts 0
protection function of the overcurrent release LSI
Complete device with protection unit (EF008906) true
switching capacity class of the circuit breaker M
Max. rated operational current of the frame size 250 A
DIN rail (top hat rail) mounting optional (EF008904) true
Region Specific PriceGroup / Headquarter Price Group 12P / 1CB
mechanical service life (switching cycles) / typical 25 000
breaking capacity maximum short-circuit current (Icu)
breaking capacity operating short-circuit current (Ics)
Suitable for DIN rail (top hat rail) mounting (EF007250) true
Type of electrical connection of main circuit (EF006819) Screw connection
type of electrical connection / for main current circuit on both sides nut keeper kit
Ground fault protection / tripping switchable / I2t=ON/OFF No
Position of connection for main current circuit (EF006671) Front side
Adjustment range undelayed short-circuit release (EF007131) ['2400', '2400']
Number of auxiliary contacts as change-over contact (EF003531) 0
arrangement of electrical connectors / for main current circuit Front terminal
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as normally closed contact (EF001377) 0
Adjustment range short-term delayed short-circuit release (EF007129) ['480', '2400']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 55.0
Electrical endurance (switching cycles) / at AC-1 / at 690 V 50/60 Hz 8 400
Compliance with the substance restrictions according to RoHS directive Since: 01.06.2012
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Silicic acid, lead s... CAS-No. 11120-22-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Silicic acid, lead saltBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V 50/60 Hz 12 000
Electrical endurance (switching cycles) / at AC-3 / at 380/415 V 50/60 Hz 6 500
Type of connectable conductor cross-section, connection screw, width x thickness , max. 25 x 8 mm
Type of connectable conductor cross-section, connection screw, width x thickness , min. 13 x 1 mm
Active power loss / for rated value of the current / at AC / in hot operating state / per pole 6.57 W
General Product ApprovalConfirmationMiscellaneousEMCDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityMiscellaneousSpecial Test CertificateMarine / ShippingotherCCS / China Classification SocietyMiscellaneousConfirmationMiscellaneous General Product Approval

Descrição do produto

AUTOMATIC SWITCH 3VA2 IEC size 250 CUTTING POWER CLASS M ICU=55KA @ 415 V 3 POLES, PROT. MOTORS ETU350M, LSI, IN=160A OVERLOAD PROTECTION IR=64A ... 160A SHORT CIRCUIT PROTECTION ISD=3... 15 X IR, II=
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top