Especificações principais
: Value
EAN: 4011209761711
UPC: Not available
Depth: 80 mm
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Value
EAN 4011209761711
UPC Not available
Depth 80 mm
Notes Sucessor:Successor portfolio 3VA; further information via www.siemens.com/3VA
Width 100 mm
Height 130 mm
Group Code P360
net weight 1.35 kg
Price Group 193
● maximum 55 °C
● minimum -40 °C
Metal Factor LCP-----
Mounting type fixed mounting
Product Group 3749
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
Commodity Code 85362090
Product family Not available
Usage category A
Net Weight (kg) 1,344 Kg
number of poles 4
Product function
Country of origin Czech Republic
Operating current
Product component
mounting position with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back
LKZ_FDB/ CatalogID LV10.1
PLM Effective Date Product is cancelled since: 01.10.2019
Packaging Quantity 1
product brand name SENTRON
● Trip indicator No
Operating frequency
Packaging Dimension 97,00 x 147,00 x 112,00
Product Description circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 4-pole, line protection trip unit TM, LI In=125A rated current IR=125A overload protection II=500A, short-circuit prot. N conductor unprotected without auxiliary release without auxiliary/alarm switch
Product designation 3VT1_5 molded case circuit breakers
Protection class IP IP40
● 1 / rated value 50 Hz
● 2 / rated value 60 Hz
● Voltage trigger No
● Auxiliary switch No
Product Lifecycle (PLM) PM410:Product cancellation
● Overload protection Yes
● suitability for use system protection
General Product Approval Declaration of Conformity
Rated voltage (EF003977) -
● undervoltage release No
Export Control Regulations ECCN : N / AL : N
Number of poles (EF001391) 4
● at 240 V / rated value 20 kA
● at 415 V / rated value 13 kA
● at 500 V / rated value 6 kA
● at 690 V / rated value 3 kA
Size of the circuit-breaker 3VT1
Standard lead time ex-works 15 Day/Days
Surcharge for Raw Materials None
● Ground fault protection No
● Phase failure detection No
● at 40 °C / rated value 125 A
● at 50 °C / rated value 110 A
Package size unit of measure MM
Operating frequency / maximum 120 1/h
Device construction (EF008240) Built-in device fixed built-in technique
Product Dimensions (W x L x H) Not available
Motor drive optional (EF007386) true
Continuous current / rated value 125 A
Insulation voltage / rated value 690 V
adjustable pick-up value current
Design of the operating mechanism toggle handle
Design of the overcurrent release TM
Motor drive integrated (EF006697) false
● of thermal overload trip unit fixed
Type of control element (EF006976) Rocker lever
Ambient temperature / during storage
Degree of protection (IP) (EF005474) IP40
Article Number (Market Facing Number) 3VT1712-2EA46-0AA0
Performance class for circuit breaker N
Rated permanent current Iu (EF001389) 125.0
With under voltage release (EF007518) false
Ambient temperature / during operation
Surge voltage resistance / rated value 8 kV
WEEE (2012/19/EU) Take-Back Obligation Yes
With switched-off indicator (EF007006) false
Product extension / optional / motor drive Yes
Overload release current setting (EF002336) ['125', '125']
Type of the driving mechanism / motor drive No
● Reference code / acc. to DIN EN 81346-2 Q
● reference code / acc. to DIN EN 61346-2 Q
Integrated earth fault protection (EF007296) false
● Suitability for use / Disconnecting means Yes
● undervoltage release with leading contact No
Number of CO contacts / for auxiliary contacts 0
Number of NC contacts / for auxiliary contacts 0
Number of NO contacts / for auxiliary contacts 0
protection function of the overcurrent release LI
Complete device with protection unit (EF008906) true
Electrical endurance (switching cycles) / typical 6 000
DIN rail (top hat rail) mounting optional (EF008904) true
Mechanical service life (switching cycles) / typical 20 000
Maximum short-circuit current breaking capacity (Icu)
Suitable for DIN rail (top hat rail) mounting (EF007250) true
Type of electrical connection / for main current circuit box terminal
Type of electrical connection of main circuit (EF006819) Frame clamp
Operational short-circuit current breaking capacity (Ics)
Position of connection for main current circuit (EF006671) Front side
Adjustment range undelayed short-circuit release (EF007131) ['500', '500']
● of instantaneous short-circuit trip unit / initial value 500 A
● for neutral conductors / Short-circuit and overload proof No
Number of auxiliary contacts as change-over contact (EF003531) 0
Arrangement of electrical connectors / for main current circuit front side
● of instantaneous short-circuit trip unit / Full-scale value 500 A
Number of auxiliary contacts as normally open contact (EF001376) 0
● of the current-dependent overload release / Full-scale value 125 A
Number of auxiliary contacts as normally closed contact (EF001377) 0
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']
Derating temperature / for the rated value of the continuous current 40 °C
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 25.0
Compliance with the substance restrictions according to RoHS directive Since: 01.11.2007
REACH Art. 33 Duty to inform according to the current list of candidates Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole 5 W
adjustable pick-up value current / of the current-dependent overload release / initial value 125 A
General Product ApprovalDeclaration of ConformityTest CertificatesotherType Test Certificates/Test ReportMiscellaneousManufacturer Declaration General Product Approval

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top