Horário de atendimento: Segunda a sexta, das 9h às 18h.
6ES7151-7FA21-0AB0 - 6ES7151-7FA21-0AB0 SIEMENS SIMATIC DP, IM151-7 F-CPU for ET200S, 192 KB work memory with integrated PROFIBUS..
Em estoque Produto em alta

6ES7151-7FA21-0AB0

6ES7151-7FA21-0AB0 SIEMENS SIMATIC DP, IM151-7 F-CPU for ET200S, 192 KB work memory with integrated PROFIBUS..

$0.00 USD
3131 em estoque
Especificações principais
: Value
EAN: 4025515080381
UPC: 040892914481
ETIM: 4
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Value
EAN 4025515080381
UPC 040892914481
ETIM 4
IDEA 4
I²t 0.09 A²·s
Depth 75 mm
Width 60 mm; DP master module: 35 mm
Alarms Yes
Height 119.5 mm
UNSPSC 14
eClass 6
Physics RS 485
— CFC Yes; Optional
— FBD Yes
— LAD Yes
— SCL Yes; Optional
— STL Yes
● MPI Yes
Isolated Yes
— DPV1 No
● Type SFB
— GRAPH Yes; Optional
Group Code R111
— Inputs 2 048 byte
— preset Z 0 to Z 7
● Inputs 2 048 byte
● Number 256
● preset 150 ms
Price Group 241
Single step Yes
— Outputs 2 048 byte
— Routing Yes; With master module
● Forcing Yes
● Outputs 2 048 byte
● overall 12
● present Yes; Ensured by SIMATIC Micro Memory Card (maintenance-free)
Metal Factor None
Status block Yes; Up to 2 simultaneously
● GSD file The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd)
Product Group 4A9E
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
— HiGraph® Yes; Optional
● Variables Inputs, outputs, memory bits, DB, times, counters
● as client No
● as server Yes
● retentive Yes; Must be restarted at each restart
● supported Yes
Commodity Code 85389091
Interface type Integrated RS 485 interface
Product family IM 151-7 F-CPU
last modified: 08/28/2020
— adjustable Yes
● Size, max. 64 kbyte
● adjustable Yes
● expandable No
● integrated 192 kbyte
Net Weight (kg) 0,259 Kg
Weight, approx. 200 g; DP master module: Approx. 100 g
— SYNC/FREEZE Yes
— lower limit 0
— upper limit 255
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Command set see instruction list
● Description See S7-300 operation list
● Granularity 1 h
● STEP 7 Lite No
● lower limit 1 ms
● upper limit 6 000 ms
Depth (EF000049) 75.0
Firmware version V3.3
Power loss, typ. 4.2 W
Rated value (DC) 24 V
Width (EF000008) 60.0
— Equidistance Yes
— Inputs, max. 2 kbyte
● Number, max. 1 024; Number range: 1 to 16000
● in AS, slave No
● to DP, slave Yes
Country of origin Germany
Height (EF000040) 119.5
— Outputs, max. 2 kbyte
● Plug-in (MMC) Yes
● in AS, master No
● to DP, master Yes; With DP slave only slave clock
● to MPI, slave Yes
LKZ_FDB/ CatalogID ST76
Packaging Quantity 1
● Nesting levels 8
● to MPI, master Yes
Configuration rules max. 63 peripheral modules per station; station width < 1 m or < 2 m; max. 10 A per load group (power module); master interface module on right next to IM 151-7 CPU (X2 interface)
Data record routing Yes; With DP master module
Interfaces/bus type 1x PROFIBUS DP
PG/OP communication Yes
Packaging Dimension 8,40 x 12,70 x 8,30
Product Description SIMATIC DP, IM151-7 F-CPU for ET200S, 192 KB work memory with integrated PROFIBUS DP interface (9-pole D-sub socket) as DP slave, without battery SIMATIC MMC required
● Inputs, default 128 byte
● Range of values 0 to 2^31 hours (when using SFC 101)
● can be read out Yes
Diagnostics function Yes
HW functional status 01
Inrush current, max. 1.8 A; Typical
— Isochronous mode No
— S7 communication Yes; Only server, configured on one side
— of which central 496
● Block encryption Yes; With S7 block Privacy
● Isochronous mode No
● Outputs, default 128 byte
Isolation tested with 500 V DC
Number of breakpoints 4
● PROFIBUS DP slave Yes; active / passive
● Address area, max. 32
● Forcing, variables Inputs, outputs
● Inputs, adjustable 2 048 byte
● PROFIBUS DP master No
● Retentivity preset MB 0 to MB 15
● per priority class 16
● usable for routing 4; As slave only with active interface, with IM 151-7 CPU as DP master
IP degree of protection IP20
Product Lifecycle (PLM) PM300:Active Product
— PG/OP communication Yes
● Number/Number range 0
● Outputs, adjustable 2 048 byte
● Plug-in (MMC), max. 8 Mbyte
● Programming package V5.5 + SP1 or higher or V5.2 + SP1 or higher + HSP 219 + Distributed Safety
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
for bit operations, typ. 0.06 µs
● Group error SF (red) Yes
IO link master (EF007298) false
for word operations, typ. 0.12 µs
● Number of startup OBs 1; OB 100
● Retentivity available Yes; MB 0 to MB 255
Export Control Regulations AL : N / ECCN : EAR99H
Number of slots (EF003077) 63
— S7 basic communication Yes
● Retentivity adjustable Yes; via non-retain property on DB
● System functions (SFC) see instruction list
Process diagnostic messages Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ
Reverse polarity protection Yes; against destruction
Standard lead time ex-works 5 Day/Days
Surcharge for Raw Materials None
System accessory (EF004118) true
● Deviation per day, max. 10 s; Typ.: 2 s
● Number of entries, max. 500
● Status/control variable Yes
● Transmission rate, max. 12 Mbit/s
● User data per job, max. 76 byte
Package size unit of measure CM
— of which powerfail-proof 100; Only the last 100 entries are retained
● Number of DPV1 alarm OBs 3; OB 55, 56, 57
● Number of GD loops, max. 8
● Number of clock memories 8; 1 memory byte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Size of GD packets, max. 22 byte
● per priority class, max. 32 kbyte; Max. 2048 bytes per block
Radio standard GSM (EF008524) false
from supply voltage 1L+, max. 320 mA; 410 mA with DP master module
— Global data communication Yes
● Number of DP slaves, max. 32; Per station
● Number of delay alarm OBs 2; OB 20, 21
● Number of variables, max. 30
● Point-to-point connection No
Input voltage at DC (EF007120) ['19.2', '28.8']
Product Dimensions (W x L x H) Not available
Radio standard GPRS (EF008523) false
Radio standard UMTS (EF008525) false
● Hardware clock (real-time) Yes
● Number of GD packets, max. 8
● automatic baud rate search Yes; only with passive interface
Output voltage at DC (EF007001) ['-', '-']
— S7 communication, as client No
— S7 communication, as server Yes
● Number of process alarm OBs 1; OB 40
● usable for OP communication 11
● usable for PG communication 11
Max. input current DC (EF007362) 0.32
for backplane bus (5 V DC), max. 700 mA
for fixed point arithmetic, typ. 0.16 µs
● System function blocks (SFB) see instruction list
● retentive and synchronizable Yes
Max. output current DC (EF007353) -
Rack-assembly possible (EF007018) -
Rail mounting possible (EF003972) true
Type of output voltage (EF008222) -
With optical interface (EF003028) false
— reserved for OP communication 1
— reserved for PG communication 1
● Length of mounting rail, max. Station width: ≤ 1 m or < 2 m
● additional within an error OB 4
Front build in possible (EF007016) -
Number of modules per system, max. 63; Centralized
● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35
Radio standard Bluetooth (EF007178) false
for floating point arithmetic, typ. 0.59 µs
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
— of which status variables, max. 30
● Number of synchronous error OBs 2; OB 121, 122
Degree of protection (IP) (EF005474) IP20
Input voltage at AC 50 Hz (EF007118) ['-', '-']
Input voltage at AC 60 Hz (EF007119) ['-', '-']
With potential separation (EF003272) true
— of which control variables, max. 14
● Number of asynchronous error OBs 6; OB 80, 82, 83 (for centralized I/O only, not for distributed I/O), 85, 86, 87
● User data per address area, max. 32 byte; Up to max. size of the transfer memory
Article Number (Market Facing Number) 6ES7151-7FA21-0AB0
Output voltage at AC 50 Hz (EF006999) ['-', '-']
Output voltage at AC 60 Hz (EF007000) ['-', '-']
Radio standard WLAN 802.11 (EF007179) false
SIL according to IEC 61508 (EF009889) 3
● usable for S7 basic communication 10
Max. input current AC 50 Hz (EF007360) -
Max. input current AC 60 Hz (EF007361) -
Number of HW-interfaces USB (EF003025) 0
Supporting protocol for ASI (EF003051) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for LON (EF003017) false
Type of electric connection (EF003961) Screw-/spring clamp connection
WEEE (2012/19/EU) Take-Back Obligation Yes
Max. output current AC 50 Hz (EF007351) -
Max. output current AC 60 Hz (EF007352) -
With integrated power supply (EF003338) false
— reserved for S7 basic communication 0
Number of HW-interfaces other (EF003027) 0
Number of interfaces PROFINET (EF006932) 0
Suitable for safety functions (EF001597) true
Wall mounting/direct mounting (EF007020) true
— Activation/deactivation of DP slaves Yes
● Number of GD packets, receiver, max. 8
Category according to EN 954-1 (EF006782) 4
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 1
Supporting protocol for Modbus (EF003057) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for TCP/IP (EF003050) false
With pluggable modules, others (EF003083) true
— adjustable for OP communication, max. 11
— adjustable for OP communication, min. 1
— adjustable for PG communication, max. 11
— adjustable for PG communication, min. 1
Supporting protocol for SUCONET (EF003060) false
Type of voltage (input voltage) (EF003033) DC
simultaneously active Alarm-S blocks, max. 300
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces parallel (EF003026) 0
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for PROFIBUS (EF003052) true
● Number of GD packets, transmitter, max. 8
● Number of entries readable in RUN, max. 499
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) ATEX gas-ex-protection, Cat. 3G
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for PROFIsafe (EF007526) true
● Behavior of the clock following POWER-ON Clock continues running after POWER OFF
● Mains/voltage failure stored energy time 5 ms
Explosion safety category for dust (EF003998) None
Number of HW-interfaces serial TTY (EF003024) 0
● Monitoring 24 V voltage supply ON (green) Yes
● Number of mounting rails that can be used 1
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for PROFINET IO (EF007525) false
Supporting protocol for SafetyBUS p (EF007527) false
With pluggable modules, digital I/O (EF003078) true
Power supply to interface (15 to 30 V DC), max. 80 mA
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for PROFINET CBA (EF007524) false
With pluggable modules, analogue I/O (EF003079) true
— adjustable for S7 basic communication, max. 10
— adjustable for S7 basic communication, min. 0
● User program protection/password protection Yes
● Size of GD packet (of which consistent), max. 22 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
Supporting protocol for INTERBUS-Safety (EF006662) false
With pluggable modules, central modules (EF003082) true
Supporting protocol for DeviceNet Safety (EF007520) false
Number of login stations for message functions, max. 12; Depending on the configured connections for PG/OP and S7 basic communication
Supporting protocol for other bus systems (EF003062) true
between PROFIBUS DP and all other circuit components Yes
Number of HW-interfaces industrial Ethernet (EF003020) 0
Supporting protocol for Foundation Fieldbus (EF007522) false
● Size of retentive memory for retentive data blocks 64 kbyte
— Direct data exchange (slave-to-slave communication) Yes
Performance level according to EN ISO 13849-1 (EF007399) Level e
With pluggable modules, communication modules (EF003080) true
● Data management on MMC (after last programming), min. 10 y
With bus coupler for modular station connection (EF003990) true
external protection for power supply lines (recommendation) 2 A min.
● Behavior of the clock following expiry of backup period Clock continues to run with the time at which the power failure occurred
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Fieldbus connection over separate bus coupler possible (EF004002) true
With pluggable modules, function and technology modules (EF003081) true
Compliance with the substance restrictions according to RoHS directive Since: 31.05.2011
REACH Art. 33 Duty to inform according to the current list of candidates 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):4,4'-isopropylidenediphenol (Bisphenol A, BPA)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
— Number of DP slaves that can be simultaneously activated/deactivated, max. 8

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top