Especificações principais
: Value
EAN: 4025515078753
UPC: 040892692839
ETIM: 4
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Value
EAN 4025515078753
UPC 040892692839
ETIM 4
IDEA 4
I²t 0.13 A²·s
Depth 75 mm
Width 120 mm; DP master module: 35 mm
Alarms Yes
Height 119.5 mm
UNSPSC 14
eClass 6
Physics Ethernet
— CFC Yes; Optional
— FBD Yes
— IRT Yes
— LAD Yes
— MRP Yes
— SCL Yes; Optional
— STL Yes
● MPI No
● UDP Yes; via integrated PROFINET interface and loadable FBs
Isolated Yes
— DPV1 Yes
● Type SFB
— GRAPH Yes; Optional
Group Code R111
— Inputs 2 048 byte
— preset Z 0 to Z 7
● Inputs 2 048 byte
● Number 256
● STEP 7 Yes; V5.5 or higher
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
● preset 150 ms
Price Group 241
Single step Yes
— Outputs 2 048 byte
— Routing Yes; With DP master module
● Forcing Yes
● Outputs 2 048 byte
● overall 12
● present Yes; Ensured by SIMATIC Micro Memory Card (maintenance-free)
Autocrossing Yes
Metal Factor None
Status block Yes; Up to 2 simultaneously
Product Group 4A9E
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
— HiGraph® Yes; Optional
— supported Yes
● Variables Inputs, outputs, memory bits, DB, times, counters
● as client Yes; via integrated PROFINET interface and loadable FBs
● as server Yes
● retentive Yes; Must be restarted at each restart
● supported Yes
Commodity Code 85389091
Interface type PROFINET
Product family IM 151-8 F PN/DP CPU
last modified: 08/28/2020
— adjustable Yes
● Size, max. 64 kbyte
● Web server Yes
● adjustable Yes
● expandable No
● integrated 256 kbyte; For program and data
Autonegotiation Yes
Net Weight (kg) 0,396 Kg
Weight, approx. 320 g; DP master module: Approx. 100 g
— PROFIenergy Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— SYNC/FREEZE Yes
— Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
— lower limit 0
— upper limit 255
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Command set see instruction list
● Description See S7-300 operation list
● Granularity 1 h
● lower limit 1 ms
● upper limit 6 000 ms
Depth (EF000049) 75.0
Firmware version V3.2
Power loss, typ. 5.5 W
Rated value (DC) 24 V
Width (EF000008) 120.0
— Equidistance Yes
— Inputs, max. 2 kbyte
— Number, max. 64
● Number, max. 1 024; Number range: 1 to 16000
● PROFINET CBA Yes
● in AS, slave No
● to DP, slave Yes; With DP master module
Country of origin Germany
Height (EF000040) 119.5
— Outputs, max. 2 kbyte
— Shared device Yes
— Updating time Minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items.
● Plug-in (MMC) Yes
● in AS, master No
● to DP, master Yes; With DP master module
● to MPI, slave No
LKZ_FDB/ CatalogID ST76
Packaging Quantity 1
— Updating times 250 µs to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU")
● Nesting levels 8
● to MPI, master No
Data record routing Yes; With DP master module
PG/OP communication Yes
Packaging Dimension 13,20 x 15,30 x 9,10
Product Description SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required
● Inputs, default 128 byte
● Number of ports 3; RJ45
● Range of values 0 to 2^31 hours (when using SFC 101)
● for maintenance Yes; MT
Diagnostics function Yes
HW functional status 01
Inrush current, max. 1.8 A; Typical
— Isochronous mode Yes; OB 61; only for PROFINET IO
— S7 communication Yes; with loadable FBs
— of which central 496
● Block encryption Yes; With S7 block Privacy
● Isochronous mode No
● Outputs, default 128 byte
Isolation tested with 500 V DC
Number of breakpoints 4
— Data length, max. 32 768 byte
● PROFIBUS DP slave No
● integrated switch Yes
● Bus fault BF (red) Yes; BF-PN
● Forcing, variables I/O
● Inputs, adjustable 2 048 byte
● PROFIBUS DP master No
● PROFINET IO Device Yes; Also simultaneously with IO Controller functionality
● Retentivity preset MB 0 to MB 15
● per priority class 16
● usable for routing 4; max.
IP degree of protection IP20
Product Lifecycle (PLM) PM300:Active Product
— PG/OP communication Yes
— Prioritized startup Yes
● Number/Number range 0
● Outputs, adjustable 2 048 byte
● Plug-in (MMC), max. 8 Mbyte
● Programming package STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
● cyclic transmission Yes
● on Ethernet via NTP Yes; As client
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
for bit operations, typ. 0.06 µs
● Group error SF (red) Yes
● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs
● acyclic transmission Yes
IO link master (EF007298) false
for word operations, typ. 0.12 µs
— HMI variable updating 500 ms
● Number of startup OBs 1; OB 100
● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
● Retentivity available Yes
● User-defined websites Yes
Export Control Regulations AL : N / ECCN : EAR99H
Number of slots (EF003077) 63
— S7 basic communication Yes; I blocks only
— of which in line, max. 64
● Number of HTTP clients 5
● PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality
● Retentivity adjustable Yes; via non-retain property on DB
● System functions (SFC) see instruction list
Process diagnostic messages Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ
Reverse polarity protection Yes; against destruction
Standard lead time ex-works 10 Day/Days
Surcharge for Raw Materials None
System accessory (EF004118) true
— Number of HMI variables 200
— Sampling interval, min. 500 ms
● Deviation per day, max. 10 s; Typ.: 2 s
● Number of entries, max. 500
● Status/control variable Yes
● Transmission rate, max. 100 Mbit/s; full duplex
● User data per job, max. 76 byte
Package size unit of measure CM
— of which powerfail-proof 100; Only the last 100 entries are retained
● Number of DPV1 alarm OBs 3; OB 55, 56, 57
● Number of clock memories 8; 1 memory byte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● per priority class, max. 32 768 byte; Max. 2048 bytes per block
Radio standard GSM (EF008524) false
from supply voltage 1L+, max. 352 mA; 426 mA with DP master module
— Global data communication No
● Number of DP slaves, max. 32; Per station
● Number of delay alarm OBs 2; OB 20, 21
● Number of variables, max. 30
● Point-to-point connection No
Input voltage at DC (EF007120) ['20.4', '28.8']
Product Dimensions (W x L x H) Not available
Radio standard GPRS (EF008523) false
Radio standard UMTS (EF008525) false
● Hardware clock (real-time) Yes
Output voltage at DC (EF007001) ['-', '-']
— Number of connections, max. 8
— S7 communication, as client No
— S7 communication, as server Yes
— User data consistency, max. 1 024 byte; with PROFINET I/O
● Number of connections, max. 8
● Number of process alarm OBs 1; OB 40
● usable for OP communication 11
● usable for PG communication 11
● usable for S7 communication 10; with loadable FBs
Max. input current DC (EF007362) 0.352
for backplane bus (5 V DC), max. 700 mA
for fixed point arithmetic, typ. 0.16 µs
● System function blocks (SFB) see instruction list
● retentive and synchronizable Yes
Max. output current DC (EF007353) -
Rack-assembly possible (EF007018) -
Rail mounting possible (EF003972) true
Type of output voltage (EF008222) -
With optical interface (EF003028) false
— User data per submodule, max. 1 024 byte
— reserved for OP communication 1
— reserved for PG communication 1
● Bus activity PROFINET (green) Yes; P1-/P2-/P3-Link
● Length of mounting rail, max. Station width: ≤ 1 m or < 2 m
● additional within an error OB 4
Front build in possible (EF007016) -
Number of modules per system, max. 63; Centralized
● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35
● Number of isochronous mode OBs 1; OB 61; only for PROFINET
Radio standard Bluetooth (EF007178) false
for floating point arithmetic, typ. 0.59 µs
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
— of which status variables, max. 30
● Number of synchronous error OBs 2; OB 121, 122
● total number of instances, max. 32
Degree of protection (IP) (EF005474) IP20
Input voltage at AC 50 Hz (EF007118) ['-', '-']
Input voltage at AC 60 Hz (EF007119) ['-', '-']
With potential separation (EF003272) true
— Data length per connection, max. 1 400 byte
— of which control variables, max. 14
● Data length per connection, max. 1 400 byte
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO)
Article Number (Market Facing Number) 6ES7151-8FB01-0AB0
Output voltage at AC 50 Hz (EF006999) ['-', '-']
Output voltage at AC 60 Hz (EF007000) ['-', '-']
Radio standard WLAN 802.11 (EF007179) false
SIL according to IEC 61508 (EF009889) 3
— Number of linked PROFIBUS devices 16
● Number of functions, master/slave 30
● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
● usable for S7 basic communication 10
Max. input current AC 50 Hz (EF007360) -
Max. input current AC 60 Hz (EF007361) -
Number of HW-interfaces USB (EF003025) 0
Supporting protocol for ASI (EF003051) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for LON (EF003017) false
Type of electric connection (EF003961) Screw-/spring clamp connection
WEEE (2012/19/EU) Take-Back Obligation Yes
— Of which IO devices with IRT, max. 64
Max. output current AC 50 Hz (EF007351) -
Max. output current AC 60 Hz (EF007352) -
With integrated power supply (EF003338) false
— Number of IO Devices per tool, max. 8
— Number of incoming interconnections 100
— Number of outgoing interconnections 100
— Switchover time on line break, typ. 200 ms; PROFINET MRP
— reserved for S7 basic communication 0
Number of HW-interfaces other (EF003027) 0
Number of interfaces PROFINET (EF006932) 3
Suitable for safety functions (EF001597) true
Wall mounting/direct mounting (EF007020) true
automatic detection of transmission rate Yes
— Activation/deactivation of DP slaves Yes
— Number of stations in the ring, max. 50
Category according to EN 954-1 (EF006782) 4
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Supporting protocol for Modbus (EF003057) true
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for TCP/IP (EF003050) true
With pluggable modules, others (EF003083) true
— Activation/deactivation of IO Devices Yes
— adjustable for OP communication, max. 11
— adjustable for OP communication, min. 1
— adjustable for PG communication, max. 11
— adjustable for PG communication, min. 1
— adjustable for S7 communication, max. 10
● Total of all master/slave connections 1 000
Change of IP address at runtime, supported Yes
Supporting protocol for SUCONET (EF003060) false
Type of voltage (input voltage) (EF003033) DC
simultaneously active Alarm-S blocks, max. 300
— Data length of all HMI variables, max. 2 000 byte
— Device replacement without swap medium Yes
— Number of connectable IO Devices, max. 128
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces parallel (EF003026) 0
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for PROFIBUS (EF003052) false
● Setpoint for the CPU communication load 50 %
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) ATEX gas-ex-protection, Cat. 3G
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for PROFIsafe (EF007526) true
● Behavior of the clock following POWER-ON Clock continues running after POWER OFF
● Mains/voltage failure stored energy time 5 ms
Explosion safety category for dust (EF003998) None
Number of HW-interfaces serial TTY (EF003024) 0
— Data length for connection type 01H, max. 1 460 byte
— Data length for connection type 11H, max. 32 768 byte
● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Monitoring 24 V voltage supply ON (green) Yes
● Number of mounting rails that can be used 1
● Number of remote interconnection partners 32
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for PROFINET IO (EF007525) true
Supporting protocol for SafetyBUS p (EF007527) false
With pluggable modules, digital I/O (EF003078) true
Power supply to interface (15 to 30 V DC), max. No
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for PROFINET CBA (EF007524) true
With pluggable modules, analogue I/O (EF003079) true
— adjustable for S7 basic communication, max. 10
— adjustable for S7 basic communication, min. 0
● User program protection/password protection Yes
— Number of connectable IO Devices for RT, max. 128
● User data per job (of which consistent), max. 76 byte
Supporting protocol for INTERBUS-Safety (EF006662) false
With pluggable modules, central modules (EF003082) true
Supporting protocol for DeviceNet Safety (EF007520) false
— several passive connections per port, supported Yes
Number of login stations for message functions, max. 12; Depending on the configured connections for PG/OP and S7 basic communication
Supporting protocol for other bus systems (EF003062) true
between PROFIBUS DP and all other circuit components Yes
— Number of IO Controllers with shared device, max. 2
Number of HW-interfaces industrial Ethernet (EF003020) 1
Supporting protocol for Foundation Fieldbus (EF007522) false
— Data length of all incoming interconnections, max. 2 000 byte
— Data length of all outgoing interconnections, max. 2 000 byte
● Size of retentive memory for retentive data blocks 64 kbyte
— Direct data exchange (slave-to-slave communication) Yes
— Number of IO devices with prioritized startup, max. 32
— Transmission frequency: Transmission interval, min. 1 ms
Performance level according to EN ISO 13849-1 (EF007399) Level e
With pluggable modules, communication modules (EF003080) true
● Data management on MMC (after last programming), min. 10 y
With bus coupler for modular station connection (EF003990) true
external protection for power supply lines (recommendation) 2 A min.
● Behavior of the clock following expiry of backup period Clock continues to run with the time at which the power failure occurred
● Number of device-internal and PROFIBUS interconnections 500
Supporting protocol for AS-Interface Safety at Work (EF007519) false
● Data length of all incoming connections master/slave, max. 4 000 byte
● Data length of all outgoing connections master/slave, max. 4 000 byte
Fieldbus connection over separate bus coupler possible (EF004002) true
With pluggable modules, function and technology modules (EF003081) true
— IO Devices changing during operation (partner ports), supported Yes
— Number of IO Devices with IRT and the option "high flexibility" 128
Compliance with the substance restrictions according to RoHS directive Since: 21.05.2010
— Number of stations that can log on for HMI variables (PN OPC/iMap) 3; 2x PN OPC/1x iMap
● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte
REACH Art. 33 Duty to inform according to the current list of candidates 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):4,4'-isopropylidenediphenol (Bisphenol A, BPA)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
— Number of DP slaves that can be simultaneously activated/deactivated, max. 8
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top