Especificações principais
: Value
EAN: 4025515075813
UPC: 662643401455
ETIM: 4
Informações do fornecedor
SIEMENS
SIEMENS
Produtos: 367174
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Value
EAN 4025515075813
UPC 662643401455
ETIM 4
IDEA 4
Depth 117 mm
Width 40 mm
Height 125 mm
UNSPSC 14
eClass 6
Group Code R116
Price Group 280
● present Yes
Metal Factor None
Product Group 2488
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit 1 Piece
● Step: low Yes
Commodity Code 85389091
Product family Analog input module with HART
last modified: 08/25/2020
● 0 to 20 mA Yes
● Step: High Yes
● Step: None Yes
Net Weight (kg) 0,250 Kg
Weight, approx. 205 g
Depth (EF000049) 117.0
Power loss, typ. 1.5 W
Width (EF000008) 40.0
● Step: Medium Yes
Country of origin Germany
Height (EF000040) 125.0
● 4 mA to 20 mA
LKZ_FDB/ CatalogID ST73
Packaging Quantity 1
● shielded, max. 800 m
Packaging Dimension 13,20 x 15,40 x 5,10
Product Description SIMATIC DP, HART analog input SM 331, 8 AI, 0/4 - 20 mA HART, for ET200M with IM153-2, 1 x 20-pole, Functions: FW update, HART auxiliary variables, redundancy, local diagnostic buffer with time stamping,
● parameterizable Yes
Diagnostics function Yes
● -20 mA to +20 mA
● Diagnostic alarm Yes
● Rated value (DC) 24 V
Isolation tested with 500 V DC
Measurement principle Sigma Delta
● Limit value alarm Yes
IP degree of protection IP20
Number of analog inputs 8
Product Lifecycle (PLM) PM300:Active Product
● short-circuit proof Yes
required front connector 20-pin
● Group error SF (red) Yes
● Supply current, max. 60 mA
● between the channels No
IO link master (EF007298) false
Input, current (EF003204) true
Input, voltage (EF003205) false
● Integration time (ms) 20 ms at 50 Hz; 16.6 ms at 60 Hz; 100 ms at 100 Hz
Export Control Regulations AL : N / ECCN : EAR99H
Input, resistor (EF003206) false
Output, current (EF003212) -
Output, voltage (EF003213) -
Standard lead time ex-works 1 Day/Days
Surcharge for Raw Materials None
System accessory (EF004118) true
Package size unit of measure CM
Supply voltage DC (EF007534) ['20.4', '28.8']
Radio standard GSM (EF008524) false
Input, thermocouple (EF003208) false
Product Dimensions (W x L x H) Not available
Radio standard GPRS (EF008523) false
Radio standard UMTS (EF008525) false
from backplane bus 5 V DC, max. 120 mA
● Reverse polarity protection Yes
Rack-assembly possible (EF007018) false
Rail mounting possible (EF003972) true
— Input resistance (0 to 20 mA) 140 Ω
Front build in possible (EF007016) true
Supply voltage AC 50 Hz (EF007532) -
Supply voltage AC 60 Hz (EF007533) -
Radio standard Bluetooth (EF007178) false
● Channel fault indicator F (red) Yes
Degree of protection (IP) (EF005474) IP20
Number of analogue inputs (EF001994) 8
— Input resistance (4 mA to 20 mA) 140 Ω
Article Number (Market Facing Number) 6ES7331-7TF01-0AB0
Input signal, configurable (EF003209) true
Number of analogue outputs (EF001995) 0
Output signal configurable (EF003214) -
Radio standard WLAN 802.11 (EF007179) false
SIL according to IEC 61508 (EF009889) -
● Integration time, parameterizable Yes
Degree of protection (NEMA) (EF011959) -
Number of HW-interfaces USB (EF003025) 0
Supporting protocol for ASI (EF003051) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for LON (EF003017) false
Type of electric connection (EF003961) Screw-/spring clamp connection
WEEE (2012/19/EU) Take-Back Obligation Yes
Analogue inputs configurable (EF008518) true
— Input resistance (-20 mA to +20 mA) 140 Ω
Analogue outputs configurable (EF008519) -
Input, resistance thermometer (EF003207) false
Number of HW-interfaces other (EF003027) 0
Number of interfaces PROFINET (EF006932) 0
Suitable for safety functions (EF001597) false
Wall mounting/direct mounting (EF007020) true
Category according to EN 954-1 (EF006782) -
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Supporting protocol for Modbus (EF003057) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for TCP/IP (EF003050) false
Voltage type of supply voltage (EF002991) -
from load voltage L+ (without load), max. 20 mA
Supporting protocol for SUCONET (EF003060) false
● between the channels and backplane bus Yes
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces parallel (EF003026) 0
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for PROFIBUS (EF003052) true
● Current, relative to input range, (+/-) 0.15 %
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) ATEX gas-ex-protection, Cat. 3G
Resolution of the analogue inputs (EF003575) 16
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for PROFIsafe (EF007526) -
Explosion safety category for dust (EF003998) None
Number of HW-interfaces serial TTY (EF003024) 0
Resolution of the analogue outputs (EF003577) -
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for PROFINET IO (EF007525) -
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for PROFINET CBA (EF007524) false
● for current measurement as 2-wire transducer Yes
● for current measurement as 4-wire transducer Yes
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for other bus systems (EF003062) true
Number of HW-interfaces industrial Ethernet (EF003020) 0
Supporting protocol for Foundation Fieldbus (EF007522) false
Performance level according to EN ISO 13849-1 (EF007399) -
● Resolution with overrange (bit including sign), max. 16 bit
● Basic conversion time, including integration time (ms) 55 ms @ 60 Hz, 65 ms @ 50 Hz, 305 ms @ 100 Hz
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Fieldbus connection over separate bus coupler possible (EF004002) false
permissible input current for current input (destruction limit), max. 40 mA
Compliance with the substance restrictions according to RoHS directive Since: 25.11.2009
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● Interference voltage suppression for interference frequency f1 in Hz 10 / 50 / 60 Hz

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top