Parâmetro Valor
5 V DC
Type block modular
Depth 54 mm
Width 35 mm
Height 126.1 mm
Output name PWM outputs
Current draw max. 150 mA
Product type I/O component
Mounting type DIN rail mounting
Operating mode PWM, pulse generator, push-pull output
Product family Axioline F
Supply voltage 5 V DC (via bus base module)
Connection name Axioline F connector
Frequency range 0 Hz ... 65535 Hz
Article revision 03
Pollution degree 2 (IEC 60664-1, EN 60664-1)
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Stripping length 8 mm
Connection method Bus base module
Mounting position any (no temperature derating)
Number of outputs 2
Pulse duty factor 0 % ... 100 %
Scope of delivery including bus base module and Axioline F connectors
Input address area 0 Byte
Nominal current IN max. 500 mA (at 24 V DC)
Nominal load, lamp max. 6 W (at nominal voltage)
Note on dimensions The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Protective circuit Surge protection; electronic (35 V, 0.5 s)
Special properties Pulse width modulation
Transmission speed 100 Mbps
Dimensional drawing
Nominal load, ohmic max. 12 W (at 24 V DC nominal voltage)
Note on application Only for industrial use
Output address area 8 Byte
Short-circuit-proof yes
Degree of protection IP20
Number of interfaces 2
Overvoltage category II (IEC 60664-1, EN 60664-1)
Supply voltage range 19.2 V DC ... 30 V DC including all tolerances, including ripple
Connection technology 2-conductor
Short-circuit current typ. 2.2 A (for approx. 1.2 µs, auto-retry after approx. 40 µs, 24 V output)
Nominal output voltage 24 V (UO- 1.1 V)
Nominal load, inductive max. 12 VA (at 24 V DC nominal voltage)
Required parameter data 1 Byte
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Transient surge protection yes
Conductor cross section AWG 24 ... 16
Required configuration data 6 Byte
Conductor cross section rigid 0.2 mm² ... 1.5 mm²
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid 0.2 mm² ... 1.5 mm²
Ambient temperature (operation) -25 °C ... 60 °C
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Conductor cross section, flexible 0.2 mm² ... 1.5 mm²
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Maximum power dissipation for nominal condition 2.05 W
Test voltage: 24 V supply (I/O) / functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC, 50 Hz, 1 min.

Descrição do produto

AxiolineF, Function module, Pulse width modulation, local bus transmission rate:100 MBit/s, protection rating:IP20, including bus socket module and AxiolineF connectors
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top