Especificações principais
: 18 V DC ... 30 V DC
Fuse: electronic
Note: Interference emission
Type: Male
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
18 V DC ... 30 V DC
Fuse electronic
Note Interference emission
Type Male
Color gray (RAL 7042)
Depth 52 mm
Width 12.3 mm
Height 45 mm
General When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).Parallel connection of multiple circuit breakers is not permitted.
Voltage < 3 V DC (Low state)
Product type Device circuit breakers
Pulse length min. 20 ms
Voltage drop 100 mV (at IN)
Humidity test 96 h, 95 % RH, 40 °C
Mounting type on base element
Shutdown time 400 ms (see time/current characteristic curve)
Identification UL Listed UL 508
Output current max. 0.2 A (Short-circuit-proof)
Output voltage 24 V DC
Product family CB E
No. of channels 1
Switch-on delay typ. 2 ms
Tripping method E (electronic)
Article revision 03
Connection method pluggable
Fail-safe element 4 A DC
Operating voltage 24 V DC
Power dissipation 0.46 W (Nominal operation)
Nominal current IN 2 A
Current consumption typ. 2.6 mA (at 24 V DC)
Degree of pollution 2
Dielectric strength max. 30 V DC (Load circuit)
Dimensional drawing
Input voltage range 7 V DC ... 30 V DC (Reset with falling edge)
Number of positions 1
Rated surge voltage 0.5 kV
Degree of protection IP30 (Actuation area)
Max. capacitive load 20000 µF
Required backup fuse not required, integrated failsafe element
Standard designation EMV
Temperature derating 2 A (at 50 °C)
Complete module depth 77.3 mm
Complete module width 12.3 mm
Vibration (operation) 3g (according to IEC 60068-2-6, Test Fc)
Complete module height 90 mm
Contact connection type Positive-switching signal output
Undervoltage switch-off < 14 V (typ. OFF)
Standards/specifications EN 61000-6-3
Active current limitation typ. 1.25 x IN
Closed circuit current I0 typ. 8 mA (When switched on)
MTBF (IEC 61709, SN 29500) 8320000 h (at 25 °C with 80 % load)
Ambient temperature (operation) -25 °C ... 50 °C (non-condensing)
Flammability rating according to UL 94 V-0
Ambient temperature (storage/transport) -40 °C ... 70 °C

Descrição do produto

Interruption. Protec. Electronic, 1-pole, active current limiter, status output and reset input, connector for base element.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação