Horário de atendimento: Segunda a sexta, das 9h às 18h.
CT 10-2PE/FSR-24 - CT 10-2PE/FSR-24 2807968 PHOENIX CONTACT Surge protection plug
Em estoque Produto em alta

CT 10-2PE/FSR-24

CT 10-2PE/FSR-24 2807968 PHOENIX CONTACT Surge protection plug

$0.00 USD
4292 em estoque
Especificações principais
GTIN: 4017918104757
Note: Made to Order (non-returnable)
Orderkey: 2807968
(General): D1 - 2.5 kA
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918104757
Note Made to Order (non-returnable)
Orderkey 2807968
(General) D1 - 2.5 kA
Catalog page Page 107 (C-6-2013)
Packing unit 1 pc
Country of origin DE (Germany)
Custom tariff number 85363010
(Ambient conditions) IEC 60664-1
Rated current (General) 200 mA (25 °C)
Type (Ambient conditions) LSA-PLUS module
Color (Ambient conditions) black
Depth (Key Commercial Data) 68.5 mm
Width (Key Commercial Data) 111 mm
Height (Key Commercial Data) 22 mm
Nominal voltage UN (General) 24 V DC
Capacity (line-line) (General) 1.1 nF (f=1 MHz / VR= 0 V)
Residual current IPE (General) ≤ 1 µA (per path)
Resistance in series (General) 10 Ω ±10 %
Capacity (line-earth) (General) 1 pF (typ.)
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Mounting type (Ambient conditions) On CT-TERMIBLOCK and LSA-PLUS disconnect strip
Input attenuation aE, sym. (General) 1.5 dB (Typ. up to 2 MHz / 50 Ω)
Max. required back-up fuse (General) 200 mA
Weight per Piece (excluding packing) 127.000 g
Housing material (Ambient conditions) PBT
Input attenuation aE, asym. (General)
Response time tA(line-line) (General) ≤ 1 ns
Connection method (Protective circuit) can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Response time tA(line-earth) (General) ≤ 100 ns
Maximum continuous voltage UC (General) 40 V DC
Standards/regulations (Connection data) IEC 61643-21
Direction of action (Ambient conditions) Line-Line & Line-Earth Ground
Impulse durability (line-line) (General) C1 - 1 kV/500 A
Surge protection fault message (General) none
Connection method IN (Protective circuit) COMTRAB plug-in system
Impulse durability (line-earth) (General) C1 - 1 kV/500 A
Connection method OUT (Protective circuit) COMTRAB plug-in system
Standards/specifications (Connection data) IEC 61643-21 2000
Residual voltage at In(line-line) (General) ≤ 55 V
Ambient temperature (operation) (Dimensions) -25 °C ... 75 °C
Operating effective current ICat UC (General) ≤ 5 µA (a-b)
Total discharge current Itotal(8/20) µs (General) 10 kA
Flammability rating according to UL 94 (Ambient conditions) V0
Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General) 7 MHz (typ.)
Nominal discharge current In(8/20) µs (line-line) (General) 5 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General) 4 MHz (typ.)
Cut-off frequency fg (3 dB), sym. in 600 Ohm system (General) 900 kHz (typ.)
Nominal discharge current In(8/20) µs (line-earth) (General) 5 kA
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 95 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 650 V
Output voltage limitation at 1 kV/µs (line-line) static (General) ≤ 60 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 5 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 650 V
Standards for cearances and creepage distances (Ambient conditions) VDE 0110-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 5 kA
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) From SW rev. 1.00

Descrição do produto

LSA-PLUS (COMTRAB CT 10) connector with coarse/fine surge protection and decoupling resistance for 10 signal circuits driven without earth potential. Nominal voltage: 24 V DC. Version: 10 two-wire cir
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top