Especificações principais
GTIN: 4017918962814
Note: Made to Order (non-returnable)
Orderkey: 2880163
(General): ≤ 180 V (C1 - 500 V / 250 A (J2 OFF))
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918962814
Note Made to Order (non-returnable)
Orderkey 2880163
(General) ≤ 180 V (C1 - 500 V / 250 A (J2 OFF))
Catalog page Page 143 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) DIN EN 50173-1
Custom tariff number 85363010
(Ambient conditions) IEC 60664-1
Rated current (General) 1.5 A (25 °C)
Type (Ambient conditions) 19" rack patch module
Color (Ambient conditions) beige
Depth (Key Commercial Data) 160 mm
Width (Key Commercial Data) 483 mm
Height (Key Commercial Data) 44 mm
Capacity (line-line) (General) typ. 20 pF
Residual current IPE (General) ≤ 1 mA (jumper 2 unplugged)
Capacity (line-earth) (General) typ. 1 pF
Degree of protection (Dimensions) IP20
Height unit (Key Commercial Data) 1 U
IEC test classification (General) C1
Mounting type (Ambient conditions) 19" rack
Input attenuation aE, sym. (General) typ. 1 dB (≤ 100 MHz)
Weight per Piece (excluding packing) 3,119.580 g
Housing material (Ambient conditions) Sheet steel
Response time tA(line-line) (General) ≤ 1 ns
Connection method (Protective circuit) RJ45
Response time tA(line-earth) (General) ≤ 1 ns
Maximum continuous voltage UC (General) 6 V DC (Core - core)
Standards/regulations (Connection data) IEC 61643-21
Degree of pollution (Ambient conditions) 2
Direction of action (Ambient conditions) Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General) C1 - 500 V / 250 A
Near-end crosstalk attenuation (General) typ. 36 dB (100 Ω system / 100 MHz)
Number of positions (Ambient conditions) 8
Response time tA (line-shield) (General) ≤ 100 ns
Surge protection fault message (General) none
Connection method IN (Protective circuit) RJ45 socket
Impulse durability (line-earth) (General) C1 - 500 V / 250 A
Overvoltage category (Ambient conditions) II
Connection method OUT (Protective circuit) RJ45 socket
Connection technology (Protective circuit) Network interfaces (e.g. Ethernet, Token Ring and CDDI/FDDI)
Standards/specifications (Connection data) IEC 61643-21 2000
Impulse durability (shield-earth) (General) C2 (4 kV / 2 kA)
Residual voltage at In(line-line) (General) ≤ 65 V
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Residual voltage at In(line-earth) (General) ≤ 45 V (J2 ON)
Operating effective current ICat UC (General) ≤ 1 mA
Residual voltage at In(shield-earth) (General) ≤ 700 V
Voltage protection level Up(line-line) (General) ≤ 50 V (C1 - 500 V / 250 A)
Voltage protection level Up(line-earth) (General) ≤ 40 V (C1 - 500 V / 250 A (J2 ON))
Total discharge current Itotal(8/20) µs (General) 10 kA
Maximum continuous voltage UC(line-earth) (General) 68 V DC (optional: +/- 6 V DC)
Voltage protection level Up(shield-ground) (General) ≤ 800 V (with insulated housing)
Nominal discharge current In(8/20) µs (line-line) (General) 350 A
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (General) > 100 MHz
Nominal discharge current In(8/20) µs (line-earth) (General) 350 A
Nominal pulse current Ian (10/1000) µs (line-line) (General) 100 A
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 100 A
Nominal discharge current In(8/20) µs (shield-earth) (General) 2.5 kA (with insulated housing)
Output voltage limitation at 1 kV/µs (line-line) static (General) ≤ 20 V
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 30 V (J2 plugged)
Standards for cearances and creepage distances (Ambient conditions) DIN VDE 0110-1
Output voltage limitation at 1 kV/µs (shield-earth) static (General) ≤ 700 V (with insulated shield)

Descrição do produto

19" rack with 8 surge-protected ports for data interfaces in Ethernet networks (1000Base-T), Token ring, FDDI/CDDI according to Class D/EN 50173 (CAT5e), connection to the protection module: RJ45 fema
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário