Especificações principais
: 2, 3, 4-wire
Note: Notes on operation Line protection for the power cable, maximum 25 A. Observe derating of the POWER COMBICON connector
Depth: 139 mm
Width: 384 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
2, 3, 4-wire
Note Notes on operation Line protection for the power cable, maximum 25 A. Observe derating of the POWER COMBICON connector
Depth 139 mm
Width 384 mm
Height 182 mm
Number 2
Ripple Permissible ripple 3.6 Vppwithin the permissible voltage range
Input name Digital inputs
Net weight 3136 g
Designation Terminal strip X13
Filter time 3 ms
Output name Digital outputs
Input voltage 24 V DC (US1)
Mounting type Wall mounting
Output current max. 500 mA (per channel)
Supply current typ. 0.25 A (at US1= 24 V; plus current of digital inputs/outputs)
Supply voltage 24 V DC (US1/ US2)
Switching rate 5 cycles per minute, maximum
Fieldbus system PROFINET
Frequency range 50 Hz ... 60 Hz (mains frequency)
Number of inputs 10
Parameterization via PROFINET
Connection method 8-pos. RJ45 socket on motor starter
Number of outputs 4
Operating voltage 360 V AC ... 550 V AC (line voltage 50/60 Hz)
Drill hole spacing 360 mm
Note on dimensions Module electronics without lower part
Type of protection Electronic short-circuit/overload protection, damping diode
Number of positions 8
Pg screw connection Pg11
Degree of protection IP67 in acc. with IEC 60529
Supply voltage range 20 V DC ... 30 V DC (including ripple)
Utilization category On the basis of AC 3
Nominal current range 0.18 A ... 2.4 A
Parameterization range 0.2 A ... 2.4 A
Air pressure (operation) 86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Power supply for sensors UINI= US1minus 1 V 500 mA Short-circuit/overload protection
Designation connection point X30 and X31
Note on weight specifications Module electronics without lower part
Input voltage range "0" signal -3 V DC ... 5 V (binary "0")
Input voltage range "1" signal 15 V DC ... 30 V DC (binary "1")
Max. current carrying capacity 10 A
Ambient temperature (operation) -25 °C ... 50 °C (non-condensing)
Air pressure (storage/transport) 86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Permissible humidity (operation) 0 % ... 85 % (non-condensing)
Typical input current per channel approx. 3 mA (for US1= 24 V)
Permissible conductor cross section max. 0.14 mm² ... 0.22 mm²
Ambient temperature (storage/transport) -25 °C ... 70 °C (non-condensing)
Permissible humidity (storage/transport) 75 % (slight temporary condensation may sometimes appear on the housing)
Minimum output voltage with nominal current US2minus 1 V

Descrição do produto

More details
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

The PROFINET motor starters are designed as distributed motor starters with IP67 protection. They perform simple drive tasks. The motor starters provide a connection for mains supply and mains continuation as well as one or two connections for a 3-phase asynchronous motor.