Horário de atendimento: Segunda a sexta, das 9h às 18h.
EMG 17-REL/KSR-G 24/2E/SO38 - EMG 17-REL/KSR-G 24/2E/SO38 2941646 PHOENIX CONTACT Functional block
Em estoque Produto em alta

EMG 17-REL/KSR-G 24/2E/SO38

EMG 17-REL/KSR-G 24/2E/SO38 2941646 PHOENIX CONTACT Functional block

$0.00 USD
3582 em estoque
Especificações principais
GTIN: 4017918080556
Orderkey: 2941646
(Coil side): 2500 VA (for 250 V AC)
Catalog page: Page 447 (C-5-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918080556
Orderkey 2941646
(Coil side) 2500 VA (for 250 V AC)
Catalog page Page 447 (C-5-2017)
Depth (Note) 62.5 mm
Packing unit 10 pc
Width (Note) 17.5 mm
Height (Note) 75 mm
Country of origin DE (Germany)
Custom tariff number 85364190
(Ambient conditions) Reverse polarity protection Polarity protection diode
Screw thread (General) M3
Contact type (Coil side) Single contact, 1 N/O contact
Connection name (General) Coil side
Stripping length (General) 8 mm
Connection method (General) Screw connection
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Coil side) AgSnO
Operating mode (Contact side) 100% operating factor
(Connection data output side) EN 50178
Net weight (SAP) (Contact side) 60.31 g
Mounting position (Contact side) any
Maximum inrush current (Coil side) 120 A (20 ms)
Type of switch contact (Coil side) Single contact
Weight per Piece (excluding packing) 60.310 g
Conductor cross section AWG (General) 24 ... 12
Maximum switching voltage (Coil side) 250 V AC/DC
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Mechanical service life (Contact side) 3x 107cycles
Conductor cross section solid (General) 0.2 mm² ... 4 mm²
Limiting continuous current (Coil side) 10 A
Protective circuit (Ambient conditions) Free-wheeling diode Damping diode
Insulation (Connection data output side) safe isolation
Screw thread (Connection data input side) M3
Typical release time (Ambient conditions) 10 ms
Conductor cross section flexible (General) 0.2 mm² ... 2.5 mm²
Typical response time (Ambient conditions) 9 ms
Ambient temperature (operation) (Dimensions) -20 °C ... 50 °C
Connection name (Connection data input side) Contact side
Nominal input voltage UN (Ambient conditions) 24 V DC
Stripping length (Connection data input side) 8 mm
Utilization restriction (Key Commercial Data) EMC: class A product, see manufacturer's declaration in the download area
Connection method (Connection data input side) Screw connection
Operating voltage display (Ambient conditions) Automatic: Yellow LED, Manual: Red LED
Interrupting rating (lamp load) max. (Coil side) on request
Typical input current at UN (Ambient conditions) 23 mA
Degree of pollution (Connection data output side) 2
Interrupting rating (ohmic load) max. (Coil side) 240 W (at 24 V DC)
Overvoltage category (Connection data output side) III
Standards/regulations (Connection data output side) IEC 60664
Ambient temperature (storage/transport) (Dimensions) -20 °C ... 70 °C
Test voltage relay winding/relay contact (Contact side) 4 kV AC (50 Hz, 1 min.)
Conductor cross section AWG (Connection data input side) 24 ... 12
Conductor cross section solid (Connection data input side) 0.2 mm² ... 4 mm²
Input voltage range in reference to UN (Ambient conditions) 0.9 ... 1.1
Power dissipation for nominal condition (Ambient conditions) 0.55 W
Conductor cross section flexible (Connection data input side) 0.2 mm² ... 2.5 mm²

Descrição do produto

Relay module for high constant currents, with soldered relay, contacts (AgSnO): Medium to large powers, 1 open contact, input voltage 24 V DC, constant current limit 10 A, with 2 inputs for manual/aut
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top