Horário de atendimento: Segunda a sexta, das 9h às 18h.
FL RED 2001E PRP 2LC - FL RED 2001E PRP 2LC 2701864 PHOENIX CONTACT Redundancy module
Em estoque Produto em alta

FL RED 2001E PRP 2LC

FL RED 2001E PRP 2LC 2701864 PHOENIX CONTACT Redundancy module

$0.00 USD
3139 em estoque
Especificações principais
: LNK/ACT Link status/data transmission Green LED
Type: Block design
Depth: 109 mm
Width: 40 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
LNK/ACT Link status/data transmission Green LED
Type Block design
Depth 109 mm
Width 40 mm
Height 100 mm
Redundancy PRP (Parallel Redundancy Protocol)
Product type Switch
Mounting type DIN rail mounting
Noise emission EN 61000-6-4
Noise immunity IEC 61850-3, IEEE 1613, EN 61000-6-2: 2005
Product family Redundancy module
Status display LEDs: US1, US2(redundant voltage supply), link and activity per port
Supply voltage 48 V DC (redundant)
Basic functions Ethernet redundancy module for the Parallel Redundancy Protocol
No. of channels 1 (RJ45 port)
Residual ripple 3.6 VPP(within the permitted voltage range)
Article revision 04
Connection method RJ45
Local diagnostics US1, US2 Supply voltage Green LED
Transmission speed 10/100 Mbps
Supply voltage (DC) 24 V DC (redundant)
Transmission length 100 m (per segment)
Transmission medium Multi-mode fiberglass
Degree of protection IP20
Supply voltage range 18 V DC ... 58 V DC
Transmission physics Copper
Air pressure (operation) 70 kPa ... 106 kPa (3000 m above sea level)
Conductor cross section AWG 24 ... 16
Data flow control/protocols IEC 61850-3, IEEE 1613
Typical current consumption 250 mA (at US= 24 V DC)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Note on the connection method Auto negotiation and autocrossing
Conductor cross section, rigid 0.2 mm² ... 1.5 mm²
Ambient temperature (operation) -40 °C ... 70 °C
Conformance with EMC directives IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion A
Air pressure (storage/transport) 70 kPa ... 106 kPa (3000 m above sea level)
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Status and diagnostic indicators LEDs: US1, US2(redundant voltage supply), link and activity per port
Conductor cross section, flexible 0.2 mm² ... 1.5 mm²
Ambient temperature (storage/transport) -45 °C ... 85 °C
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Maximum power dissipation for nominal condition 6 W

Descrição do produto

Ethernet redundancy module for redundant networks with the PRP redundancy protocol.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top