Especificações principais
GTIN: 4055626045887
Orderkey: 2905415
(General): 457 V AC (120 min / withstand mode)
Catalog page: Page 33 (C-4-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626045887
Orderkey 2905415
(General) 457 V AC (120 min / withstand mode)
Catalog page Page 33 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) N-G
Custom tariff number 85363010
(Ambient conditions) PBT-FR
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) light grey RAL 7035
Response time tA (General) ≤ 100 ns
SPD Type (Connection data) 2CA
Depth (Key Commercial Data) 74.5 mm
Width (Key Commercial Data) 71.2 mm
(Additional technical data) 1 A DC (30 V DC)
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 95.2 mm
Nominal voltage UN (General) 240 V AC (TN-S)
Nom. voltage (Connection data) 240 V AC
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 0.01 mA
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 125 A (< 55 °C)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
TOV behavior at UT(L-N) (General) 415 V AC (5 s / withstand mode)
Mounting type (Ambient conditions) DIN rail: 35 mm
TOV behavior at UT(N-PE) (General) 1200 V AC (200 ms / withstand mode)
Vibration (operation) (Dimensions) 5g (5 - 500 Hz/2.5 h/X, Y, Z)
Nominal frequency (Connection data) 50/60 Hz
Mode of protection (Connection data) L-N
Residual voltage Ures(L-N) (General) ≤ 1.5 kV (at In)
Weight per Piece (excluding packing) 724.000 g
Housing material (Ambient conditions) PA 6.6-FR 20% GF
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Residual voltage Ures(L-PE) (General) ≤ 2.5 kV (at In)
Residual voltage Ures(N-PE) (General) ≤ 1.5 kV (at In)
Tightening torque (UL specifications) 4 lbf-in.
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Horizontal pitch (Key Commercial Data) 4 Div.
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Maximum continuous voltage UC (General) 350 V AC
Mode of protection (Ambient conditions) L-N
Rated load current IL (Connection data) 50 A
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 2
Screw thread (Additional technical data) M2
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) IEC 61643-11 2011
Voltage protection level Up(L-N) (General) ≤ 1.5 kV
Power distribution system (Connection data) Single phase
Voltage protection level Up(L-PE) (General) ≤ 2.5 kV
Voltage protection level Up(N-PE) (General) ≤ 1.5 kV
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-S
IEC test classification (Ambient conditions) I / II
Short-circuit current rating ISCCR (General) 50 kA
Stripping length (Additional technical data) 7 mm
Connection method (Additional technical data) Plug-in/screw connection via COMBICON
Max. backup fuse with branch wiring (General) 315 A (gG)
Operating current (Additional technical data) 10 mA AC ... 1 A AC
Operating voltage (Additional technical data) 12 V AC ... 250 V AC
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 18 mm
Tightening torque (Additional technical data) 0.25 Nm
Connection method (Indicator/remote signaling) Fork-type cable lug
Nominal discharge current In (Connection data) 20 kA
Switching function (Additional technical data) PDT contact
Tightening torque (Indicator/remote signaling) 4.5 Nm
Conductor cross section AWG (UL specifications) 30 ... 14
Tightening torque (UL indicator/remote signaling) 40 lbf-in.
Follow current interrupt rating Ifi(L-N) (General) 50 kA
Follow current interrupt rating Ifi(N-PE) (General) 100 A
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General) 50 kA
Max. backup fuse with V-type through wiring (General) 125 A (gG)
Short-circuit current rating (SCCR) (Connection data) 50 kA
Voltage protection rating VPR (L-G) (Connection data) 1500 V
Voltage protection rating VPR (L-N) (Connection data) 1500 V
Voltage protection rating VPR (N-G) (Connection data) 1200 V
Nominal discharge current In(8/20) µs (L-N) (General) 25 kA
Conductor cross section AWG (Additional technical data) 28 ... 16
Nominal discharge current In(8/20) µs (L-PE) (General) 25 kA
Nominal discharge current In(8/20) µs (N-PE) (General) 100 kA
Short-circuit current rating ISCCR (Protective circuit) 100 kA (264 V AC)
Conductor cross section AWG (Indicator/remote signaling) 13 ... 2
Maximum discharge current Imax(8/20) µs (L-N) (General) 50 kA
Conductor cross section solid (Additional technical data) 0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (L-PE) (General) 50 kA
Conductor cross section solid (Indicator/remote signaling) 2.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling) 3 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Maximum continuous operating voltage MCOV (Connection data) 350 V AC
Conductor cross section flexible (Additional technical data) 0.14 mm² ... 1.5 mm²
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 16 mm²
Maximum discharge current Imax(8/20) µs (Protective circuit) 100 kA (AS NZS 1768:2007)
Impulse discharge current (10/350) µs (L-N), charge (General) 12.5 As
Follow current quenching capacity Ifi(L-N) (Protective circuit) 100 kA (264 V AC)
Impulse discharge current (10/350) µs (L-PE), charge (General) 12.5 As
Impulse discharge current (10/350) µs (N-PE), charge (General) 50 As
Impulse discharge current (10/350) µs (L-N), specific energy (General) 160 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), specific energy (General) 160 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), specific energy (General) 2500 kJ/Ω
Impulse discharge current (10/350) µs (L-N), peak current value Iimp (General) 25 kA
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp (General) 25 kA
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp (General) 100 kA

Descrição do produto

Plug-in lightning current arrester according to type 1/class I, for single-phase power grids with separate N and PE (L1, PE, N).