Horário de atendimento: Segunda a sexta, das 9h às 18h.
IB IL 400 MLR 1-8A - IB IL 400 MLR 1-8A 2727365 PHOENIX CONTACT Inline terminal
Em estoque Produto em alta

IB IL 400 MLR 1-8A

IB IL 400 MLR 1-8A 2727365 PHOENIX CONTACT Inline terminal

$0.00 USD
3598 em estoque
Especificações principais
: Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Note: Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Type: modular
Depth: 109 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Note Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Type modular
Depth 109 mm
Width 63 mm
Height 224 mm
Filter time 0.2 ms
Current draw max. 50 mA
Product type I/O component
Assembly note To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below.
ID code (hex) BF
Mounting type DIN rail mounting
ID code (dec.) 191
Operating mode Process data mode with one byte
Product family Inline
Supply voltage 7.5 V DC (via voltage jumper)
Register length 1 Byte
Number of inputs 1
Protection class I (IEC 61140, EN 61140, VDE 0140-1)
Connection method Inline data jumper
Length code (dec) 129
Length code (hex) 81
Mounting position Panel mounting on horizontal DIN rail
Power consumption max. 4.2 W (entire device)
Input address area 1 Byte
Transmission speed 500 kbps
Dimensional drawing
Number of positions 4
Output address area 1 Byte
Degree of protection IP20
Diagnostics messages Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Number of interfaces 2
Process data channel 8 bit
Supply voltage range 19.2 V DC ... 28.8 V DC (including all tolerances, including ripple)
Transmission physics Copper
Required parameter data 5 Byte
Air pressure (operation) 80 kPa ... 106 kPa (up to 2000 m above sea level)
Required configuration data 5 Byte
Ambient temperature (operation) -25 °C ... 55 °C
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) 10 % ... 85 % (non-condensing)
Test voltage: Local bus/400 V level 1.2 kV AC, 50 Hz, 1 min.
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (storage/transport) 10 % ... 85 % (non-condensing)
Test voltage: Local bus/Brake control switch 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage UL/ 400 V level 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage US/ 400 V level 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage UL/ brake control switch 1.2 kV AC, 50 Hz, 1 min.
Test voltage: Supply voltage US/ brake control switch 1.2 kV AC, 50 Hz, 1 min.

Descrição do produto

Inline power terminals, electromechanical direct start controller, up to 3.7 kW / 400 V AC
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top