Horário de atendimento: Segunda a sexta, das 9h às 18h.
IB IL AO 2/UI-XC-PAC - IB IL AO 2/UI-XC-PAC 2701389 PHOENIX CONTACT Inline terminal
Em estoque Produto em alta

IB IL AO 2/UI-XC-PAC

IB IL AO 2/UI-XC-PAC 2701389 PHOENIX CONTACT Inline terminal

$0.00 USD
4021 em estoque
Especificações principais
: Transient protection; Suppressor diode
Type: modular
Depth: 71.5 mm
Width: 12.2 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Transient protection; Suppressor diode
Type modular
Depth 71.5 mm
Width 12.2 mm
Height 119.8 mm
Output name Analog outputs
Current draw max. 65 mA
Data formats IB IL, S7-compatible
Product type I/O component
ID code (hex) 5B
Mounting type DIN rail mounting
ID code (dec.) 91
Product family Inline
Supply voltage 7.5 V DC (via voltage jumper)
Connection name Inline connector
Register length 64 bit
Article revision 03
Pollution degree 2 (IEC 60664-1, EN 60664-1)
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Stripping length 8 mm
Connection method Inline data jumper
Length code (dec) 04
Length code (hex) 04
Number of outputs 2
Scope of delivery including Inline connector and labeling field
Input address area 8 Byte
Note on dimensions Housing dimensions
Protective circuit Short-circuit and overload protection; Electronic
Special properties Extreme conditions version
Transmission speed 500 kbps
D/A conversion time typ. 10 µs
Dimensional drawing
Note on application Only for industrial use
Output address area 8 Byte
Process data update bus-synchronous
Degree of protection IP20
Diagnostics messages Failure of the internal I/O supply I/O error message sent to the bus coupler
Number of interfaces 2
Overvoltage category II (IEC 60664-1, EN 60664-1)
Process data channel 64 bit
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Transmission physics Copper
Connection technology 2-conductor
Current output signal 0 mA ... 20 mA
Voltage output signal 0 V ... 10 V
Required parameter data 10 Byte
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
D/A converter resolution 12 bit
Permissible cable length max. 250 m (The specifications refer to nominal operation after complying with installation instructions. The specifications refer to the following reference cable type: Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812)
Conductor cross section AWG 28 ... 16
Required configuration data 5 Byte
Conductor cross section rigid 0.08 mm² ... 1.5 mm²
Conductor cross section, rigid 0.08 mm² ... 1.5 mm²
Ambient temperature (operation) -25 °C ... 55 °C (Standard)
Load/output load current output ≤ 450 Ω
Load/output load voltage output > 1 kΩ
Representation of output values 12 bits (11 bits + sign bit)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Conductor cross section, flexible 0.08 mm² ... 1.5 mm²
Ambient temperature (storage/transport) -40 °C ... 85 °C
Note regarding the connection technology shielded
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Test voltage: 7.5 V supply (bus logic)/functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V analog supply (analog I/O)/functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC, 50 Hz, 1 min.

Descrição do produto

Inline, Analog output terminal, Analog outputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, -20 mA... 20 mA, connection technology: 2 conductors, transmission rate on the local bus:
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação