IBS IL 24 RB-T-2MBD-PAC - IBS IL 24 RB-T-2MBD-PAC 2861962 PHOENIX CONTACT Branch terminal
Em estoque Produto em alta

IBS IL 24 RB-T-2MBD-PAC

IBS IL 24 RB-T-2MBD-PAC 2861962 PHOENIX CONTACT Branch terminal

$0.00 USD
3912 em estoque
Especificações principais
Type: modular
Depth: 71.5 mm
Width: 12.2 mm
Height: 135 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Type modular
Depth 71.5 mm
Width 12.2 mm
Height 135 mm
Current draw typ. 29 mA
Product type I/O component
ID code (hex) 04
Mounting type DIN rail mounting
ID code (dec.) 04
Product family Inline
Supply voltage 24 V DC (via voltage jumper)
Connection name Inline connector
Register length 0 bit
Article revision 07
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Stripping length 8 mm
Connection method Inline data jumper
Length code (dec) 0
Length code (hex) 0
Scope of delivery including Inline connector and labeling field
Input address area 0 Byte
Special properties with remote bus branch
Transmission speed 2 Mbps
Dimensional drawing
Note on application Only for industrial use
Output address area 0 Byte
Degree of protection IP20
Process data channel 0 bit
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Transmission physics RS-485
Required parameter data 0 Byte
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section AWG 28 ... 16
Required configuration data 0 Byte
Conductor cross section rigid 0.08 mm² ... 1.5 mm²
Conductor cross section, rigid 0.08 mm² ... 1.5 mm²
Ambient temperature (operation) -25 °C ... 55 °C
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
Conductor cross section, flexible 0.08 mm² ... 1.5 mm²
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
Maximum power dissipation for nominal condition 0.7 W
Number of local bus devices that can be connected max. 63 (Consider the logic current consumed by the devices; the branch terminal does not count as an Inline station device.)
Test voltage: 5 V supply incoming remote bus / functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply outgoing remote bus, electrically isolated from functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from the functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus terminal module supply, 5 V communications power, bus branch terminal electrically isolated from functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply 500 V AC, 50 Hz, 1 min.

Descrição do produto

INTERBUS branch terminal block, 2MBD, with accessories, with remote bus switch, 24 V DC
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top