Horário de atendimento: Segunda a sexta, das 9h às 18h.
IL EIP BK DI8 DO4 2TX-PAC - IL EIP BK DI8 DO4 2TX-PAC 2897758 PHOENIX CONTACT Bus coupler
Em estoque Produto em alta

IL EIP BK DI8 DO4 2TX-PAC

IL EIP BK DI8 DO4 2TX-PAC 2897758 PHOENIX CONTACT Bus coupler

$0.00 USD
4474 em estoque
Especificações principais
GTIN: 4046356157926
Orderkey: 2897758
Catalog page: Page 126 (C-6-2017)
Depth (Note): 71.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356157926
Orderkey 2897758
Catalog page Page 126 (C-6-2017)
Depth (Note) 71.5 mm
Packing unit 1 pc
Width (Note) 80 mm
Height (Note) 119.8 mm
Country of origin DE (Germany)
(Digital outputs) Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse
Custom tariff number 85176200
(Ambient conditions) Failure of the actuator supply Yes
Designation (General) Inline local bus
Designation (Interfaces) System limits of the bus coupler
No. of channels (General) 2
Note on dimensions (Note) Specfications with connectors
Dimensional drawing (Note)
Connection method (General) Inline data jumper
(Standards and Regulations) No hazardous substances above threshold values
Output name (Digital inputs) Digital outputs
Transmission speed (General) 500 kbps / 2 Mbps (automatic detection, no combined system)
Input name (Inline potentials) Digital inputs
Transmission physics (General) Ethernet in RJ45 twisted pair
Net weight (Ambient conditions) 320 g
Output voltage (Digital inputs) 24 V DC -1 V (At nominal current)
Degree of protection (Dimensions) IP20
Input voltage (Inline potentials) 24 V DC
Connection method (Digital inputs) Inline connector
Mechanical tests (Digital outputs) Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Mounting type (Ambient conditions) DIN rail
Number of outputs (Digital inputs) 4
Protection class (Digital outputs) III, IEC 61140, EN 61140, VDE 0140-1
(System limits of the bus coupler) Short-circuit protection of the analog supply
Amount of process data (Interfaces) max. 512 Byte (per station)
Nominal load, lamp (Digital inputs) 12 W
Type of protection (Digital inputs) Short-circuit and overload protection
Nominal load, ohmic (Digital inputs) 12 W
Number of inputs (Inline potentials) 8
Weight per Piece (excluding packing) 320.000 g
Air pressure (operation) (Dimensions) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Inline potentials) Inline connector
China RoHS (Standards and Regulations) Environmentally friendly use period: unlimited = EFUP-e
Connection technology (Digital inputs) 3-wire
Type of protection (Inline potentials) Reverse polarity protection
Nominal output voltage (Digital inputs) 24 V DC
Note on the connection method (General) Auto negotiation and autocrossing
Nominal load, inductive (Digital inputs) 12 VA (1.2 H, 48 Ω)
Number of supported devices (Interfaces) max. 63 (per station)
Connection technology (Inline potentials) 3-wire
Diagnostics messages (Ambient conditions) Short-circuit / overload of the digital outputs Yes
Typical response time (Inline potentials) approx. 500 µs
Ambient temperature (operation) (Dimensions) -25 °C ... 60 °C
Description of the input (Inline potentials) EN 61131-2 type 1
Air pressure (storage/transport) (Dimensions) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible conductor cross section (General) 0.14 mm² ... 0.22 mm² (twisted pair)
Permissible humidity (operation) (Dimensions) 10 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data) 1
Designation (System limits of the bus coupler) Segment circuit supply (US)
Nominal input current at UIN (Inline potentials) typ. 3 mA
Supply voltage (System limits of the bus coupler) 24 V DC (via Inline connector)
Connection in acc. with standard (Digital outputs) CUL
Input voltage range "0" signal (Inline potentials) -30 V DC ... 5 V DC
Input voltage range "1" signal (Inline potentials) 15 V DC ... 30 V DC
Maximum output current per module (Digital inputs) 2 A
Note on weight specifications (Ambient conditions) with connectors
Maximum output current per channel (Digital inputs) 500 mA
Ambient temperature (storage/transport) (Dimensions) -25 °C ... 85 °C
Power consumption (System limits of the bus coupler) typ. 3 W (entire device)
Power supply unit (System limits of the bus coupler) max. 8 A DC (sum of UM+ US)
Number of devices with parameter channel (Interfaces) max. 8
Permissible humidity (storage/transport) (Dimensions) 10 % ... 95 % (non-condensing)
Type of protection (System limits of the bus coupler) Short-circuit protection of the communications power
Typical input current per channel (Inline potentials) typ. 3 mA
Current consumption (System limits of the bus coupler) 6 mA (Without connected peripherals)
Delay at signal change from 0 to 1 (Inline potentials) 1.2 ms
Delay at signal change from 1 to 0 (Inline potentials) 1.2 ms
Supply voltage range (System limits of the bus coupler) 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Number of local bus devices that can be connected (Interfaces) max. 61 (on board I/Os are two devices)
Maximum output current per module / terminal block (Digital inputs) 2 A
Number of supported branch terminals with remote bus branch (Interfaces) 0

Descrição do produto

Inline, Bus coupler, EtherNet/IP™, RJ45 female, Digital inputs: 8, 24 VDC, connection technology: 3 conductors, Digital outputs:4, 24 VDC, 500 mA, connection technology:3 conductors, transmission spee
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top