Horário de atendimento: Segunda a sexta, das 9h às 18h.
K8AC-CT200L - K8AC-CT200L K8AC0016D 184037 OMRON Current Transformer for K8AB-AS3
Em estoque Produto em alta

K8AC-CT200L

K8AC-CT200L K8AC0016D 184037 OMRON Current Transformer for K8AB-AS3

$0.00 USD
3494 em estoque
Especificações principais
: 10 to 100 A AC, 20 to 200 A AC
EMC: EN 60947-5-1
Weight: Approx. 150 g
K8AK-AW3: AC input (45 to 65 Hz)
Informações do fornecedor
OMRON
OMRON
Produtos: 41472
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
10 to 100 A AC, 20 to 200 A AC
EMC EN 60947-5-1
Weight Approx. 150 g
K8AK-AW3 AC input (45 to 65 Hz)
Indicators Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM): Red LED
Operate (SV) Operating value setting range
Repeat error Operating value
Reset (HYS.) Hysteresis
Case material PC and ABS
100 to 240 VAC K8AK-AW1 100-240 VAC
Operating time ±50 ms (at 25°C and 65% humidity, rated power supply voltage)
Electrical life 50,000 operations at 5 A, 250 VAC or 30 VDC
Mechanical life 10,000,000 operations
Operating power Isolated power supply
Operating value 100% operation at set value
Resetting method Manual reset/automatic reset (switchable)Manual reset: Turn OFF operating power for 1 s or longer
Safety standards UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC
Measuring current Supply voltage
Overload capacity K8AK-AW1/-AW2
Operating time (T) 0.1 to 30 s
Current transformer Input range
Storage temperature -25 to 65°C (with no condensation or icing)
Applicable standards Conforming standards
Degree of protection Terminal section: IP20
Input frequency range K8AK-AW1/-AW2
Maximum contact current 5 A
Maximum contact voltage 250 VAC or 30 VDC
Operating voltage range 85% to 110% of rated operating voltage
Size in mm (H × W × D) 90 × 22.5 × 100
Maximum switching capacity 1,250 VA, 150 W
Rated power supply frequency 50/60 Hz±5 Hz (AC power supply)
10 to 100 A AC,20 to 200 A AC 24 VAC/DC
Ambient operating temperature -20 to 60°C (with no condensation or icing)
Operating power ON lock (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.)Note: Enabled only for overcurrent operation
0.1 to 1 A AC/DC,0.5 to 5 A AC/DC 24 VAC/DC
Output relays(1 × SPDT, normally closed operation) Resistive load
2 to 20 mA AC/DC,10 to 100 mA AC/DC,50 to 500 mA AC/DC 24 VAC/DC

Descrição do produto

Current transformer for monitoring relays, high current monitoring capacity
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

These single-phase current relays monitor over- and undercurrents. Manual resetting and automatic resetting are supported by one relay. The start-up lock and operating time can be set separately. The relay warning status is easily monitored with the LED indicator.

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top