MACX MCR-T-UI-UP-SP - MACX MCR-T-UI-UP-SP 2811860 PHOENIX CONTACT Temperature measuring transducer
Em estoque Produto em alta

MACX MCR-T-UI-UP-SP

MACX MCR-T-UI-UP-SP 2811860 PHOENIX CONTACT Temperature measuring transducer

$0.00 USD
3871 em estoque
Especificações principais
GTIN: 4046356629119
Orderkey: 2811860
(General): Class I, Zone 2, Group IIC T6
Catalog page: Page 128 (C-5-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356629119
Orderkey 2811860
(General) Class I, Zone 2, Group IIC T6
Catalog page Page 128 (C-5-2017)
Depth (Note) 114.5 mm
Packing unit 1 pc
Width (Note) 17.5 mm
(Input data) 1 A (30 V DC)
Height (Note) 99 mm
ATEX (General)  II 3 G Ex nA nC ic IIC T4 Gc X
IECEx (General) Ex nA nC ic IIC T4 Gc X
Country of origin DE (Germany)
(Connection data) Class I, Zone 2, Group IIC T6
Custom tariff number 85437090
DNV GL-EMC (General) A
Conformance (General) CE-compliant
SIL (Connection data) 2
ATEX (Connection data)  II 3 G Ex nA nC ic IIC T4 Gc X
Color (Connection data) gray
IECEx (Connection data) Ex nA nC ic IIC T4 Gc X
Output name (Input data) Relay output
UL, USA/Canada (General) UL 508 Listed
Contact type (Input data) 1 PDT
DNV GL-Humidity (General) B
DNV GL-Enclosure (General) Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (General) A
Noise immunity (Dimensions) EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
DNV GL-Temperature (General) B
Conformance (Connection data) CE-compliant
Contact material (Input data) AgSnO2, hard gold-plated
Designation (Connection data) Input/switching output
Maximum altitude (Dimensions) ≤ 2000 m
Electrical isolation (General) 4-way, between input/output/power supply/switching output
Power consumption (Output data) < 1.5 W
Stripping length (Power supply) 8 mm
Connection method (Power supply) Push-in connection
UL, USA/Canada (Connection data) UL 508 Listed
Current output signal (Input data) 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Housing material (Connection data) PA 6.6-FR
Supply voltage range (Output data) 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Maximum inrush current (Input data) 0.5 A (30 V AC)
Weight per Piece (excluding packing) 150.000 g
Degree of pollution (Connection data) 2
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Configurable/programmable (Input data) no
Electrical isolation (Connection data) 375 V (Peak value in accordance with EN 60079-11)
Maximum switching voltage (Input data) 30 V AC (30 V DC)
Overvoltage category (Connection data) II
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Electromagnetic compatibility (General) Conformance with EMC directive
Input signal range (Ambient conditions) -1000 mV ... 1000 mV
Max. current output signal (Input data) 22 mA
Max. voltage output signal (Input data) ± 11 V
Ambient temperature (operation) (Dimensions) -20 °C ... 65 °C
Load/output load current output (Input data) ≤ 600 Ω (at 20 mA)
Load/output load voltage output (Input data) ≥ 10 kΩ
Permissible humidity (operation) (Dimensions) typ. 5 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data) 1
Conductor cross section AWG max. (Power supply) 16
Conductor cross section AWG min. (Power supply) 24
Electromagnetic compatibility (Connection data) Conformance with EMC directive
Flammability rating according to UL 94 (General) V0
Temperature measuring range (Ambient conditions) -250 °C ... 2500 °C (Range depending on the sensor type)
Conductor cross section solid max. (Power supply) 1.5 mm²
Conductor cross section solid min. (Power supply) 0.2 mm²
Maximum temperature coefficient (Connection data) 0.01 %/K
Potentiometer resistance range (Ambient conditions) 0 Ω ... 50 kΩ
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Behavior in the event of a sensor error (Input data) according to NE 43 or freely configurable
Conductor cross section flexible max. (Power supply) 1.5 mm²
Conductor cross section flexible min. (Power supply) 0.2 mm²
Sensor types that can be used (TC) (Ambient conditions) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Flammability rating according to UL 94 (Connection data) V0
Sensor types (RTD) that can be used (Ambient conditions) Pt, Ni, Cu sensors: 2, 3, 4-wire

Descrição do produto

Freely programmable temperature converter with analog output and 1 limit value relay, standard configuration, thermoresistors in 2, 3 or 4 conductor technology, thermocouples, galvanic separation, wid
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação