Especificações principais
GTIN: 4017918104962
Note: Made to Order (non-returnable)
Orderkey: 2749398
(General): 0.1 dB (up to 10 kHz 600 Ω system)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918104962
Note Made to Order (non-returnable)
Orderkey 2749398
(General) 0.1 dB (up to 10 kHz 600 Ω system)
Catalog page Page 100 (TT-2002)
Packing unit 5 pc
Country of origin DE (Germany)
(Connection data) E VDE 0845-3-1
Custom tariff number 85363010
Rated current (General) 450 mA (25 °C)
Type (Ambient conditions) DIN rail module, one-piece
Color (Ambient conditions) black
Depth (Key Commercial Data) 54.9 mm
Width (Key Commercial Data) 47.6 mm
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data) 77.5 mm
Nominal voltage UN (General) 5 V DC
Resistance in series (General) 4.4 Ω
VDE requirement class (General) C2
Degree of protection (Dimensions) IP20
IEC test classification (General) C2
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) DIN rail: 35 mm
Input attenuation aE, sym. (General) typ. 0.1 dB (up to 40 kHz 150 Ω system)
Weight per Piece (excluding packing) 102.420 g
Input attenuation aE, asym. (General) 0.5 dB (up to 0.1 MHz 50 Ω system)
Response time tA(line-line) (General) 1 ns
Stripping length (Protective circuit) 8 mm
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Connection method (Protective circuit) Screw connection
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Response time tA(line-earth) (General) ≤ 100 ns
Maximum continuous voltage UC (General) 5.8 V DC
Standards/regulations (Connection data) Draft IEC 64644-1
Direction of action (Ambient conditions) Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Surge protection fault message (General) none
Connection method IN (Protective circuit) Screw terminal blocks
Connection method OUT (Protective circuit) Screw terminal blocks
Residual voltage at In(line-line) (General) ≤ 9 V
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Operating effective current ICat UC (General) ≤ 2 mA
Response time tA (line-signalground) (General) ≤ 1 ns
Conductor cross section AWG (Protective circuit) 24 ... 12
Voltage protection level Up(line-line) (General) ≤ 9 V
Voltage protection level Up(line-earth) (General) ≤ 450 V
Conductor cross section solid (Protective circuit) 0.2 mm² ... 4 mm²
Residual voltage at In(line-signalground) (General) ≤ 9 V
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Voltage protection level Up(line-signalground) (General) ≤ 9 V
Nominal discharge current In(8/20) µs (line-line) (General) 10 kA
Nominal discharge current In(8/20) µs (line-earth) (General) 10 kA
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 9 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 450 V
Output voltage limitation at 1 kV/µs (line-line) static (General) ≤ 9 V
Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm system (General) 600 kHz
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 10 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 450 V
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system (General) 200 kHz
Cut-off frequency fg (3 dB), asym. (GND) in 600 Ohm system (General) 50 kHz
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 10 kA
Output voltage limitation at 1 kV/µs (line-signalground) static (General) ≤ 9 V
Max. discharge current Imax(8/20) µs maximum (line-signalground) (General) 10 kA

Descrição do produto

Rail mounting module with coarse and fine surge protection for RS-485 interface with TTL level, for mounting on NS 35/7.5, housing width: 50 mm
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top