Horário de atendimento: Segunda a sexta, das 9h às 18h.
PLT-SEC-T3-120-FM - PLT-SEC-T3-120-FM 2905228 PHOENIX CONTACT Type 3 surge protection device
Em estoque Produto em alta

PLT-SEC-T3-120-FM

PLT-SEC-T3-120-FM 2905228 PHOENIX CONTACT Type 3 surge protection device

$0.00 USD
4018 em estoque
Especificações principais
: T3
Note: 2012
Type: DIN rail module, two-section, divisible
Depth: 74.5 mm (incl. DIN rail 7.5 mm)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
T3
Note 2012
Type DIN rail module, two-section, divisible
Depth 74.5 mm (incl. DIN rail 7.5 mm)
Width 17.7 mm
Height 90 mm
EN type T3
Altitude ≤ 2000 m (amsl)
SPD Type 4CA
Product type Device protection
Screw thread M3
Mounting type DIN rail: 35 mm
Material group I
Product family SEC Family
Connection name Remote fault indicator contact
Nominal voltage 120 V DC
Number of ports One
Horizontal pitch 1 Div.
Housing material PA 6.6-FR 20 % GF
Pollution degree 2
Connection method Screw connection
Nominal frequency 50/60 Hz
Operating current 3 A AC
Operating voltage 250 V AC
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque 0.8 Nm
Mode of protection L-N
Nominal voltage UN 120 V AC (TN-S)
Switching function N/C contact
Dimensional drawing
Direction of action 1L-N & N-PE
Insulating material PA 6.6-FR 20% GF
Number of positions 2
Combination wave UOC 6 kV
Degree of protection IP20
Nominal frequency fN 50 Hz (60 Hz)
Overvoltage category III
Residual current IPE ≤ 5 µA
CTI value of material 600
Rated load current IL 26 A (30 °C)
Response time tA(L-N) ≤ 25 ns
Vibration (operation) 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z)
Response time tA(L-PE) ≤ 100 ns
Response time tA(N-PE) ≤ 100 ns
IEC test classification III
TOV behavior at UT(L-N) 240 V AC (5 s / withstand mode)
Standards/specifications EN 61643-11
TOV behavior at UT(L-PE) 240 V AC (5 s / withstand mode)
TOV behavior at UT(N-PE) 1200 V AC (200 ms / safe failure mode)
Power distribution system Single phase
Conductor cross section AWG 24 ... 12
Reference test voltage UREF 132 V AC
Nominal discharge current In 3 kA
Standby power consumption PC ≤ 150 mVA (at UREF)
Conductor cross section rigid 0.2 mm² ... 4 mm²
Maximum continuous voltage UC 150 V AC
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 70 °C
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Permissible humidity (operation) 5 % ... 95 %
Voltage protection level Up(L-N) ≤ 0.85 kV
Voltage protection level Up(L-PE) ≤ 0.95 kV
Voltage protection level Up(N-PE) ≤ 0.95 kV
Short-circuit current rating ISCCR 1.5 kA AC
Max. backup fuse with branch wiring not required
Measured limiting voltage MLV (L-G) 760 V
Measured limiting voltage MLV (L-N) 780 V
Measured limiting voltage MLV (N-G) 760 V
Flammability rating according to UL 94 V-0
Measured limiting voltage MLV (L+) - G 760 V
Measured limiting voltage MLV (L-) - G 760 V
Nominal discharge current In(8/20) µs 3 kA
Ambient temperature (storage/transport) -40 °C ... 70 °C
Maximum continuous operating voltage MCOV 150 V AC
Measured limiting voltage MLV (L+) - (L-) 780 V

Descrição do produto

Pluggable device protection, according to type 3/class III, for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with integrated surge-proof fuse and remote indica
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top