Especificações principais
GTIN: 4055626257488
Orderkey: 2907922
(General): 1332 V AC (200 ms / safe failure mode)
Packing unit: 10 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626257488
Orderkey 2907922
(General) 1332 V AC (200 ms / safe failure mode)
Packing unit 10 pc
Country of origin DE (Germany)
(Connection data) 5 kA DC
(UL specifications) EN 61643-11 2012
Custom tariff number 85363030
(Ambient conditions) PA 6.6-FR
(Protective circuit) (DC+/DC-) - PE
Altitude (Dimensions) ≤ 6000 m (amsl (above mean sea level))
Type (Ambient conditions) Male
Color (Ambient conditions) light gray RAL 7035
SPD Type (Connection data) 2CA
Depth (Key Commercial Data) 65.7 mm
Width (Key Commercial Data) 17.5 mm
EN type (Ambient conditions) T2 / T3
Height (Key Commercial Data) 46.7 mm
Nominal voltage UN (General) 120 V AC (TN-S)
Combination wave UOC (General) 6 kV
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 5 µA
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Response time tA(L-N) (General) ≤ 25 ns
Response time tA(L-PE) (General) ≤ 100 ns
Response time tA(N-PE) (General) ≤ 100 ns
Degree of protection (Dimensions) IP20
Nominal voltage (Connection data) 150 V DC
TOV behavior at UT(L-N) (General) 240 V AC (5 s / withstand mode)
Mounting type (Ambient conditions) on base element
TOV behavior at UT(L-PE) (General) 240 V AC (5 s / withstand mode)
TOV behavior at UT(N-PE) (General) 1200 V AC (200 ms / safe failure mode)
Vibration (operation) (Dimensions) 5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data) 50/60 Hz
Mode of protection (Connection data) L-N
Number of ports (Ambient conditions) One
Weight per Piece (excluding packing) 33.160 g
Housing material (Ambient conditions) PA 6.6-FR 20% GF
Reference test voltage UREF (General) 132 V AC
Horizontal pitch (Key Commercial Data) 1 Div.
Standby power consumption PC (General) ≤ 10.6 mVA (at UREF)
Maximum continuous voltage UC (General) 150 V AC
Mode of protection (Ambient conditions) L-N
Mode of protection (Protective circuit) (DC+) - (DC-)
Rated load current IL (Connection data) 20 A
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 2
Voltage protection level Up(L-N) (General) ≤ 0.75 kV (at UOC)
Power distribution system (Connection data) Single phase
Voltage protection level Up(L-PE) (General) ≤ 0.85 kV
Voltage protection level Up(N-PE) (General) ≤ 0.85 kV
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-S
Short-circuit current rating ISCCR (General) 10 kA AC
Standards/specifications (UL specifications) IEC 61643-11 2011
Connection method (Additional technical data) pluggable
Max. backup fuse with branch wiring (General) 32 A (gG / B / C)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Nominal discharge current In (Connection data) 5 kA
Max. discharge current Imax(8/20) µs (General) 10 kA
Nominal discharge current In(8/20) µs (General) 5 kA
Maximum continuous voltage UC (Protective circuit) 150 V DC
Impulse durability (line-line) (Protective circuit) D1 - 500 A
Surge protection fault message (Ambient conditions) optical
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Impulse durability (line-earth) (Protective circuit) D1 - 500 A
Short-circuit current rating (SCCR) (Connection data) 10 kA AC
Voltage protection rating VPR (L-G) (Connection data) 900 V
Voltage protection rating VPR (L-N) (Connection data) 800 V
Voltage protection rating VPR (N-G) (Connection data) 900 V
Short-circuit current rating ISCCR (Protective circuit) 0.25 kA DC (without additional backup fuse)
Flammability rating according to UL 94 (Ambient conditions) V-0
Maximum continuous operating voltage MCOV (Connection data) 150 V AC
Pulse discharge current Iimp(10/350) µs (line-line) (Protective circuit) 0.5 kA
Pulse discharge current Iimp(10/350) µs (line-earth) (Protective circuit) 0.5 kA
IEC test classification (in accordance with IEC 61643-21) (Protective circuit) D1

Descrição do produto

Replacement connector for type 2/3 surge protection from the PLT-SEC-...-UT/PT product series. Nominal voltage 120 V.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top