Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSI-MOS-RS232/FO 850 E - PSI-MOS-RS232/FO 850 E 2708371 PHOENIX CONTACT FO converters
Em estoque Produto em alta

PSI-MOS-RS232/FO 850 E

PSI-MOS-RS232/FO 850 E 2708371 PHOENIX CONTACT FO converters

$0.00 USD
4704 em estoque
Especificações principais
GTIN: 4017918974077
Orderkey: 2708371
Catalog page: Page 333 (C-6-2017)
Depth (Note): 105 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918974077
Orderkey 2708371
Catalog page Page 333 (C-6-2017)
Depth (Note) 105 mm
Packing unit 1 pc
Width (Note) 35 mm
Height (Note) 99 mm
Country of origin DE (Germany)
(Digital outputs) Class I, Div. 2, Groups A, B, C, D
(Serial interface) Multi-mode fiberglass
Custom tariff number 85176200
(Ambient conditions) Class I, Div. 2, Groups A, B, C, D
Altitude (Dimensions) 5000 m (For restrictions see manufacturer's declaration)
ATEX (Digital outputs)  II 3 G Ex nA nC IIC T4 Gc X
(Optical interface FO) 42 V AC
Shock (Digital outputs) 15g in all directions in acc. with IEC 60068-2-27
Signal (Digital outputs) ± 1 kV
ATEX (Ambient conditions)  II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
MTBF (Ambient conditions) 320 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
Color (Ambient conditions) green
Comments (Digital outputs) Criterion B
Interface 1 (Power supply) V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Connection method (General) COMBICON plug-in screw terminal block
Noise immunity (Dimensions) EN 61000-6-2:2005
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
DNV GL-EMC (Digital outputs) B
Conformance (Digital outputs) CE-compliant
Test result (Digital outputs) 15g, 11 ms period, half-sine shock pulse
Wavelength (Serial interface) 850 nm
Supply voltage range (General) 18 V DC ... 30 V DC
Type of test (Digital outputs) Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Net weight (Ambient conditions) 221.1 g
Conformance (Ambient conditions) CE-compliant
Connection method (Power supply) D-SUB 9 plug
Noise emission (Digital outputs) EN 55011
Noise immunity (Digital outputs) EN 61000-6-2:2005
Nominal supply voltage (General) 24 V DC (With UL approval)
UL, USA/Canada (Digital outputs) Class I, Zone 2, AEx nc IIC T5
DNV GL-Humidity (Digital outputs) A
Degree of protection (Dimensions) IP20
DNV GL-Enclosure (Digital outputs) Required protection according to the Rules shall be provided upon installation on board
DNV GL-Vibration (Digital outputs) A
Max. current consumption (General) 120 mA
Noxious gas test (Digital outputs) ISA-S71.04-1985 G3 Harsh Group A
Output name (Optical interface FO) Relay output
Transmission length (Power supply) ≤ 15 m
Transmission medium (Power supply) Copper
Contact discharge (Digital outputs) ± 6 kV
Noise emission (Ambient conditions) EN 55011
UL, USA/Canada (Ambient conditions) Class I, Zone 2, AEx nc IIC T5
Connection method (Serial interface) B-FOC (ST®)
DNV GL-Temperature (Digital outputs) B
Weight per Piece (excluding packing) 221.100 g
Housing material (Ambient conditions) PA 6.6-FR
Typical current consumption (General) 120 mA (24 V DC)
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Transmission medium (Serial interface) PCF fiber
Shipbuilding approval (Digital outputs) DNV GL
Standards/regulations (Digital outputs) EN 55011
Vibration (operation) (Digital outputs) in acc. with IEC 60068-2-6: 5g, 150 Hz
Number of outputs (Optical interface FO) 1
Serial transmission speed (Power supply) 115.2 kbps (NRZ)
Transmission protocol (Serial interface) Transparent to protocol for RS-232 interface
Electrical isolation (Ambient conditions) VCC // V.24 (RS-232)
Output description (Optical interface FO) Alarm output
Bit distortion, input (Ambient conditions) ± 35 % (permitted)
Transmission channels (Ambient conditions) 2 (1/1), RxD, TxD, full duplex
Bit distortion, output (Ambient conditions) < 6.25 %
Ambient temperature (operation) (Dimensions) -20 °C ... 60 °C
Permissible humidity (operation) (Dimensions) 30 % ... 95 % (non-condensing)
Transmit capacity, minimum (Serial interface) -4.6 dBm (200/230 µm)
Utilization restriction (Key Commercial Data) EMC: class A product, see manufacturer's declaration in the download area
Conductor cross section AWG max. (Power supply) 14
Conductor cross section AWG min. (Power supply) 24
Electromagnetic compatibility (Digital outputs) Conformance with EMC Directive 2014/30/EU
Minimum receiver sensitivity (Serial interface) -33.2 dBm
Maximum switching voltage (Optical interface FO) 60 V DC
Conductor cross section solid max. (Power supply) 2.5 mm²
Conductor cross section solid min. (Power supply) 0.2 mm²
Connection in acc. with standard (Digital outputs) CUL
Electromagnetic compatibility (Ambient conditions) Conformance with EMC Directive 2014/30/EU
Limiting continuous current (Optical interface FO) 0.46 A
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Conductor cross section flexible max. (Power supply) 2.5 mm²
Conductor cross section flexible min. (Power supply) 0.2 mm²
Test voltage data interface/power supply (Ambient conditions) 1.5 kVrms(50 Hz, 1 min.)
Transmission length incl. 3 dB system reserve (Serial interface) 2800 m (with F-K 200/230 8 dB/km with quick mounting connector)
Free from substances that could impair the application of coating (Digital outputs) according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard

Descrição do produto

Fiber Optic Converter with Integrated Optical Diagnostics, Alarm Contact, for RS-232 Interfaces up to 115.2 kBit/s, Terminal Equipment with a Fiber Optic Interface (BFOC), 850 nm, for PCF/Fiberglass C
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top