Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-MC31-2SDO-1DO-24DC-SP - PSR-MC31-2SDO-1DO-24DC-SP 1015503 PHOENIX CONTACT Safety relay module for safety shut-off mats, switching st..
Em estoque Produto em alta

PSR-MC31-2SDO-1DO-24DC-SP

PSR-MC31-2SDO-1DO-24DC-SP 1015503 PHOENIX CONTACT Safety relay module for safety shut-off mats, switching st..

$0.00 USD
4857 em estoque
Especificações principais
GTIN: 4055626496467
Orderkey: 1015503
(Drawings):
Depth (Note): 114.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626496467
Orderkey 1015503
(Drawings)
Depth (Note) 114.5 mm
Packing unit 1
Width (Note) 12.5 mm
Height (Note) 116.6 mm
(Power supply) NPN, IEC 61131-2, type 3
(Alarm outputs) < 175 ms (manual, monitored start)
(Digital inputs) max. 4.7 µF (1 A load)
ETIM 5.0 (eCl@ss) EC001449
ETIM 6.0 (eCl@ss) EC001449
ETIM 7.0 (eCl@ss) EC001449
(Digital outputs) non-safety-related
Indication (Times) 1 x red LED
Net weight (Times) 104.382 g
pluggable (General) Yes
Custom tariff number 85371098
Housing color (Times) yellow
Mounting type (Times) DIN rail mounting
Status display (Times) 3 x green LED
Block diagram (Drawings)
Housing material (Times) PBT
Current (Digital outputs) max. 100 mA
Input name (Power supply) External release
Mounting position (Times) vertical or horizontal
Voltage (Digital outputs) approx. 22 V DC (Us- 2 V)
Filter time (Power supply) max. 1.5 ms (Test pulse width of low test pulses)
Stripping length (General) 8 mm
Connection method (General) Push-in spring connection
Ohmic load (Digital inputs) min. 12 Ω
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times) IP20
Output name (Digital inputs) 14, 24
Restart time (Alarm outputs) < 250 ms (Boot time)
eCl@ss 8.0 (Classifications) 27371819
eCl@ss 9.0 (Classifications) 27371819
Assembly instructions (Times) See derating curve
Designation (Digital outputs) M1
Inrush current (Power supply) < 10 mA (Typically with US, Δt
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Recovery time (Alarm outputs) 250 ms (following demand of the safety function)
Response time (Alarm outputs) < 10 ms (Take the extension of the response time into consideration if you switch several devices in sequence.)
Category (Connection capacity) 4
Nominal operating mode (Times) 100% operating factor
Inrush current (Digital inputs) max. 4.8 A (Δt = 10 ms)
Number of inputs (Power supply) 1
Output current (Digital inputs) max. 2.4 A
Output voltage (Digital inputs) ≥ 23 V DC (Us- 1 V)
Designation (Ambient conditions) A1/A2
Filter time (Ambient conditions) 1 ms (For the logic. At A1 in the event of voltage dips at Us)
Leakage current (Digital inputs) max. 1 mA (in the safe state)
Designation (Connection capacity) EN 62061
Operating voltage display (Times) 1 x green LED
Current consumption (Power supply) 7 mA
Min. load current (Digital inputs) 2 mA
Number of outputs (Digital inputs) 2
Utilization restriction (Drawings) EMC: class A product, see manufacturer's declaration in the download area
Inrush current (Ambient conditions) < 5 A (Δt = 200 µs at Us)
Number of outputs (Digital outputs) 1
Output description (Digital inputs) Safety-related digital outputs
Stop category (Connection capacity) 0
Type of protection (Digital inputs) Freewheeling circuit for inductive loads
Concurrence input 1/2 (Power supply)
Max. inductive load (Digital inputs) max. 1 H
Output description (Digital outputs) PNP
Switching frequency (Digital inputs) 1 Hz (Resistive, inductive, capacitive)
(Safety-related characteristic data) 50 V AC
Max. capacitive load (Digital inputs) max. 10 µF (2.4 A load)
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Conductor cross section solid (General) 0.2 mm² ... 1.5 mm²
Description of the input (Power supply) safety-related
Protective circuit (Ambient conditions) Parallel protection against polarity reversal Suppressor diode Provide external protection, see safety notes. Fuse type: 5 A FF
Maximum inrush current (Digital outputs) 500 mA (Δt = 1 ms at Us)
Typical pickup time at US (Alarm outputs) < 200 ms (with Uswhen controlled via A1)
Conductor cross section flexible (General) 0.2 mm² ... 1.5 mm²
Shock (Safety-related characteristic data) 30g
Short-circuit protection (Digital outputs) Yes
Protective circuit/component (Power supply) Suppressor diode
Typical response time at US (Alarm outputs) < 200 ms (automatic start)
Ambient temperature (operation) (Dimensions) -40 °C ... 70 °C (observe derating)
Performance level (PL) (Connection capacity) e
Power consumption at US (Ambient conditions) typ. 1.3 W
Conductor cross section AWG / kcmil (General) 24 ... 16
Input current range "0" signal (Power supply) 0 mA ... 2 mA (S10, S12)
Input voltage range "0" signal (Power supply) 0 V DC ... 5 V DC
Input voltage range "1" signal (Power supply) 11 V DC ... 30 V DC
Protective circuit/component (Digital outputs) Suppressor diode
Conformance (Safety-related characteristic data) CE-compliant
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Output voltage when switched off (Digital inputs) < 5 V DC (in the safe state)
Safety Integrity Level (SIL) (Connection capacity) 3
Min. degree of protection of inst. location (Times) IP54
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 70 °C
Rated control supply current IS (Ambient conditions) typ. 54 mA (No load)
Degree of pollution (Safety-related characteristic data) 2
Overvoltage category (Safety-related characteristic data) III
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178, EN 60947-5-1
Vibration (operation) (Safety-related characteristic data) 10 Hz ... 150 Hz, 5g
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance (Power supply) 150 Ω
Rated control circuit supply voltage US (Ambient conditions) 24 V DC -20 % / +25 % (provide external protection)
Rated insulation voltage (Safety-related characteristic data) 50 V
Safety Integrity Level Claim Limit (SIL CL) (Connection capacity) 3
Rated surge voltage/insulation (Safety-related characteristic data) Basic insulation 4 kV between all current paths and housing
Limitation of the voltage induced on circuit interruption (Digital inputs) max. 50 V
Conductor cross section, flexible, with ferrule, with plastic sleeve (General) 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve (General) 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Descrição do produto

Safety switching device for safety mats, switching buses, emergency stops, safety gates, light curtains up to SIL 3, cat. 4, PL e, single-channel or dual-channel mode, manual or automatic start, 2 saf
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Detalhes técnicos

Block diagram

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top