Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-SCP-24DC/FSP2/2X1/1X2 - PSR-SCP- 24DC/FSP2/2X1/1X2 2986575 PHOENIX CONTACT Coupling relay
Em estoque Produto em alta

PSR-SCP-24DC/FSP2/2X1/1X2

PSR-SCP- 24DC/FSP2/2X1/1X2 2986575 PHOENIX CONTACT Coupling relay

$0.00 USD
3653 em estoque
Especificações principais
GTIN: 4046356553322
Orderkey: 2986575
Catalog page: Page 287 (C-6-2017)
Depth (Note): 114.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356553322
Orderkey 2986575
Catalog page Page 287 (C-6-2017)
Depth (Note) 114.5 mm
Packing unit 1 pc
Width (Note) 17.5 mm
(Input data) 150 mA Fast-blow (N/C contact)
Height (Note) 99 mm
(Output data) IP54
Country of origin DE (Germany)
pluggable (General) Yes
Custom tariff number 85364900
(Ambient conditions) Test pulse rate = 15 x Test pulse width
Screw thread (General) M3
Net weight (Output data) 108.77 g
Output fuse (Input data) 10 A gL/gG (N/O contact)
Relay type (Output data) Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data) 2 enabling current paths
Category (Connection data) 1 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %)
Stripping length (General) 7 mm
Connection method (General) Screw connection
Housing color (Output data) yellow
Mounting type (Output data) DIN rail mounting
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Input data) AgCuNi, + 0.2 µm Au
Designation (Connection data) EN 50156
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Housing material (Output data) PBT
Sq. Total current (Input data) 50 A2(observe derating)
Mounting position (Output data) any
Stop category (Connection data) 0
Switching capacity (Input data) min. 75 mW
Filter time (Ambient conditions) max. 5 ms (at A1 in the event of voltage dips at Us)
Degree of protection (Output data) IP20
Recovery time (Ambient conditions) 1 s
Inrush current (Ambient conditions) max. 100 mA
Maximum inrush current (Input data) 5 A (N/O contact)
Inrush current, minimum (Input data) 5 mA (N/O contact / N/C contact)
Mechanical service life (Input data) 10x 106cycles
Nominal operating mode (Output data) 100% operating factor
Weight per Piece (excluding packing) 108.770 g
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Maximum switching voltage (Input data) 250 V AC/DC (N/O contact / N/C contact, observe the load curve)
Minimum switching voltage (Input data) 15 V AC/DC (N/O contact / N/C contact)
Protective circuit (Ambient conditions) Surge protection Suppressor diode, 33 V (A1 - A2)
Limiting continuous current (Input data) 5 A (N/O contact, pay attention to the derating)
Performance level (PL) (Connection data) c (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90 %)
Typical release time (Ambient conditions) 50 ms
Conductor cross section AWG max. (General) 12
Conductor cross section AWG min. (General) 24
Shock (Safety-related characteristic data) 15g
Ambient temperature (operation) (Dimensions) -20 °C ... 55 °C (observe derating)
Conductor cross section solid max. (General) 2.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Power consumption at US (Ambient conditions) typ. 1.32 W
Utilization restriction (Key Commercial Data) 1
Operating voltage display (Ambient conditions) 1 x yellow LED
Safety Integrity Level (SIL) (Connection data) 2
Conductor cross section flexible max. (General) 2.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Typ. starting time with Us (Ambient conditions) 50 ms
Conformance (Safety-related characteristic data) CE-compliant
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions) 0.5 Hz
Interrupting rating (ohmic load) max. (Input data) 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W)
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 70 °C
Rated control supply current IS (Ambient conditions) typ. 55 mA
Degree of pollution (Safety-related characteristic data) 2
Maximum interrupting rating (inductive load) (Input data) 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W)
Min. degree of protection of inst. location (Output data) IP54
Overvoltage category (Safety-related characteristic data) III
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178/VDE 0160
Vibration (operation) (Safety-related characteristic data) 10 Hz ... 150 Hz, 2g
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions) 24 V DC -15 % / +10 %
Rated insulation voltage (Safety-related characteristic data) 250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data) 1 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )
Rated surge voltage/insulation (Safety-related characteristic data) Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (31/32), (13/14, 23/24)

Descrição do produto

Safe coupling relay for high and low demand SIL 2 applications, couples digital output signals to the peripheral device, 2 trip circuits, 1 indication contact, module for Safe State Off application, i
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto