Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-SCP-24UC/ESA4/3X1/1X2/B - PSR-SCP- 24UC/ESA4/3X1/1X2/B 2963763 PHOENIX CONTACT Safety relays
Em estoque Produto em alta

PSR-SCP-24UC/ESA4/3X1/1X2/B

PSR-SCP- 24UC/ESA4/3X1/1X2/B 2963763 PHOENIX CONTACT Safety relays

$0.00 USD
4259 em estoque
Especificações principais
GTIN: 4017918878085
Orderkey: 2963763
Catalog page: Page 21 (IF-2009)
Depth (Note): 114.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918878085
Orderkey 2963763
Catalog page Page 21 (IF-2009)
Depth (Note) 114.5 mm
Packing unit 1 pc
Width (Note) 22.5 mm
(Input data) 6 A gL/gG NEOZED (N/C contact)
Height (Note) 99 mm
(Output data) IP54
Country of origin DE (Germany)
pluggable (General) Yes
Custom tariff number 85371098
(Ambient conditions) 10 ms (two-channel)
Screw thread (General) M3
Net weight (Output data) 200.7 g
Output fuse (Input data) 10 A gL/gG NEOZED (N/O contact)
Relay type (Output data) Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data) 3 enabling current paths
Category (Connection data) 4
Stripping length (General) 7 mm
Connection method (General) Screw connection
Housing color (Output data) yellow
Mounting type (Output data) DIN rail mounting
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Input data) AgSnO2, + 0.2 µm Au
Designation (Connection data) EN 62061
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Sq. Total current (Input data) 72 A2(ITH2= I12+ I22+ I32)
Mounting position (Output data) any
Stop category (Connection data) 0
Degree of protection (Output data) IP20
Recovery time (Ambient conditions) 1 s
Maximum inrush current (Input data) 6 A
Status display (Ambient conditions) Green LED
Inrush current, minimum (Input data) 25 mA
Mechanical service life (Input data) approx. 107cycles
Nominal operating mode (Output data) 100% operating factor
Switching capacity min. (Input data) 0.4 W
Weight per Piece (excluding packing) 200.700 g
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Maximum switching voltage (Input data) 250 V AC/DC
Minimum switching voltage (Input data) 15 V AC/DC
Protective circuit (Ambient conditions) Surge protection Suppressor diode
Limiting continuous current (Input data) 6 A (N/O contact)
Performance level (PL) (Connection data) e
Typical release time (Ambient conditions) 45 ms (single-channel)
Concurrence input 1/2 (Ambient conditions)
Conductor cross section AWG max. (General) 12
Conductor cross section AWG min. (General) 24
Shock (Safety-related characteristic data) 15g
Typical response time (Ambient conditions) 100 ms (automatic start)
Ambient temperature (operation) (Dimensions) -20 °C ... 55 °C
Conductor cross section solid max. (General) 2.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Nominal input voltage UN (Ambient conditions) 24 V AC/DC
Utilization restriction (Key Commercial Data) EMC: class A product, see manufacturer's declaration in the download area
Operating voltage display (Ambient conditions) Green LED
Safety Integrity Level (SIL) (Connection data) 3
Switching capacity (360/h cycles) (Input data) 6 A (24 V DC)
Conductor cross section flexible max. (General) 2.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Typical input current at UN (Ambient conditions) 140 mA AC
Interrupting rating (ohmic load) max. (Input data) 144 W (24 V DC, τ = 0 ms)
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 70 °C
Degree of pollution (Safety-related characteristic data) 2
Maximum interrupting rating (inductive load) (Input data) 48 W (24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data) IP54
Overvoltage category (Safety-related characteristic data) III
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178/VDE 0160
Vibration (operation) (Safety-related characteristic data) 10 Hz ... 150 Hz, 2g
Input voltage range in reference to UN (Ambient conditions) 0.85 ... 1.1
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Rated insulation voltage (Safety-related characteristic data) 250 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data) 3
Voltage at input/start and feedback circuit (Ambient conditions) approx. 24 V DC
Max. permissible overall conductor resistance (Ambient conditions) approx. 50 Ω (Input and start circuits at UN)
Rated surge voltage/insulation (Safety-related characteristic data) 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)

Descrição do produto

Safety relay for emergency stop control and safety doors up to SIL 3 or category 4, PL e according to EN ISO 13849, two-channel operation, 3 trip circuits, nominal input voltage 24 V DC, plug-in screw
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top