Horário de atendimento: Segunda a sexta, das 9h às 18h.
PSR-SCP-24UC/ESAM4/3X1/1X2/B - PSR-SCP- 24UC/ESAM4/3X1/1X2/B 2900509 PHOENIX CONTACT Safety relays
Em estoque Produto em alta

PSR-SCP-24UC/ESAM4/3X1/1X2/B

PSR-SCP- 24UC/ESAM4/3X1/1X2/B 2900509 PHOENIX CONTACT Safety relays

$0.00 USD
3113 em estoque
Especificações principais
: Safety door
Depth: 114.5 mm
Shock: 15g
Width: 22.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Safety door
Depth 114.5 mm
Shock 15g
Width 22.5 mm
Height 99 mm
Category 4
pluggable yes
Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Application Emergency stop
Concurrence
Filter time 5 ms (at A1 in the event of voltage dips at Us)
Output fuse 10 A gL/gG (Enabling current paths)
Product type Safety relays
Screw thread M3
Assembly note See derating curve
Mounting type DIN rail mounting
Recovery time 1 s (following demand of the safety function)
Stop category 0
Identification CE-compliant
Inrush current < 3.5 A (Δt = 3 ms at Us)
Product family PSRclassic
Status display LED (green)
Color (Housing) yellow (RAL 1018)
Article revision 06
Contact material AgSnO2, + 0.2 µm Au
Housing material Polyamide
Maximum altitude ≤ 2000 m (Above sea level)
Stripping length 7 mm
Connection method Screw connection
Mounting position vertical or horizontal
Sq. Total current 72 A2(Enabling current paths)
Protective circuit Surge protection; Suppressor diode
Current consumption typ. 38 mA (S12)
Note on application Only for industrial use
Degree of protection IP20
Typical release time 20 ms (on demand via the sensor circuit)
Standards/regulations DIN EN 60947-1
Typical response time 100 ms (Monitored/manual start)
Vibration (operation) 10 Hz ... 150 Hz, 2g
Contact switching type 3 enabling current paths
Maximum inrush current 6 A
Nominal operating mode 100% operating factor
Performance level (PL) e (5 A DC13; 5 A AC15; 8760 switching cycles/year)
Inrush current, minimum 10 mA
Mechanical service life approx. 107cycles
Power consumption at US typ. 1.68 W (DC)
Switching capacity min. 100 mW
Rated insulation voltage 250 V
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 10 V AC/DC
Operating voltage display Green LED
Typ. starting time with Us 250 ms (when controlled via A1)
Conductor cross-section AWG 24 ... 12
Limiting continuous current 6 A (Observe derating and load limit curve)
Typical input current at UN 70 mA DC (at Us)
Safety Integrity Level (SIL) 3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Rated surge voltage/insulation See section “Insulation coordination”
Ambient temperature (operation) -20 °C ... 55 °C (observe derating)
Rated control supply current IS typ. 70 mA
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Interrupting rating (ohmic load) max. see load limit curve
Input voltage range in reference to UN 0.85 ... 1.1
Ambient temperature (storage/transport) -40 °C ... 70 °C
Rated control circuit supply voltage US 24 V DC -15 % / +10 %
Min. degree of protection of inst. location IP54
Voltage at input/start and feedback circuit approx. 24 V DC
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance approx. 50 Ω (Input and start circuits at US)
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Maximum power dissipation for nominal condition 16.44 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.04 W + 14.4 W)
Switching capacity in accordance with IEC 60947-5-1 6 A (DC13, enabling current paths)

Descrição do produto

Safety relay for emergency stop control and safety doors up to SIL 3 or category 4, PL e according to EN ISO 13849, two-channel operation, 3 trip circuits, nominal input voltage 24 V DC, plug-in screw
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top