Horário de atendimento: Segunda a sexta, das 9h às 18h.
PT 2X1-VF-120AC - PT 2X1-VF-120AC 2859327 PHOENIX CONTACT Surge protection device
Em estoque Produto em alta

PT 2X1-VF-120AC

PT 2X1-VF-120AC 2859327 PHOENIX CONTACT Surge protection device

$0.00 USD
4021 em estoque
Especificações principais
GTIN: 4017918974565
Note: Made to Order (non-returnable)
Orderkey: 2859327
(General): C3 - 25 A
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918974565
Note Made to Order (non-returnable)
Orderkey 2859327
(General) C3 - 25 A
Catalog page Page 114 (C-4-2017)
Packing unit 10 pc
Country of origin DE (Germany)
Capacity (General) typ. 3 pF
Custom tariff number 85363010
(Ambient conditions) DIN VDE 0110-1
Rated current (General) 6 A
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) black
Response time tA (General) ≤ 100 ns
Depth (Key Commercial Data) 51.7 mm
Energy absorption (General) 85 J
Width (Key Commercial Data) 17.5 mm
(Remote indication contact) IEC 61643-21
Height (Key Commercial Data) 44.8 mm
Nominal voltage UN (General) 120 V AC
Residual current IPE (General) ≤ 4 µA
Resistance in series (General) 0 Ω
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) DIN rail: 35 mm
Connection method (Connection data) Screw connection
Max. required back-up fuse (General) 6 A (e.g. D01 gL/gG)
Weight per Piece (excluding packing) 62.140 g
Housing material (Ambient conditions) PA 6.6
Stripping length (Protective circuit) 8 mm
Voltage protection level Up (General) ≤ 1 kV (C2 - 2 kA)
Connection method (Protective circuit) Screw connection
Horizontal pitch (Key Commercial Data) 1 Div.
Tightening torque (Protective circuit) 0.8 Nm
Maximum continuous voltage UC (General) 175 V AC
Degree of pollution (Ambient conditions) 2
Direction of action (Ambient conditions) Line-Line & Line-Earth Ground
Number of positions (Ambient conditions) 2
Surge protection fault message (General) none
Tightening torque, min (Connection data) 0.8 Nm
Connection method IN (Protective circuit) Screw terminal blocks
Impulse durability (line-earth) (General) C1 - 1 kV/500 A
Overvoltage category (Ambient conditions) III
Connection method OUT (Protective circuit) Screw terminal blocks
Complete module depth (Key Commercial Data) 65.5 mm
Complete module width (Key Commercial Data) 17.7 mm
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Complete module height (Key Commercial Data) 90 mm
Residual voltage at In(line-earth) (General) ≤ 600 V
Operating effective current ICat UC (General) ≤ 2 µA
Max. discharge current Imax(8/20) µs (General) 8 kA
Conductor cross section AWG (Protective circuit) 24 ... 12
Nominal discharge current In(8/20) µs (General) 3 kA
Voltage protection level Up(line-line) (General)
Standards/regulations (Remote indication contact) EN 61643-21
Voltage protection level Up(line-earth) (General) ≤ 900 V (C1 - 500 A)
Conductor cross section solid (Protective circuit) 0.2 mm² ... 4 mm²
Pulse discharge current Iimp(10/350) µs (General) 300 A
Total discharge current Itotal(8/20) µs (General) 8 kA
Standards/specifications (Remote indication contact) EN 61643-21 2002
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Switching function (Connection, equipotential bonding) N/C contact
Flammability rating according to UL 94 (Ambient conditions) V-0
Nominal discharge current In(8/20) µs (line-earth) (General) 3 kA
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 40 A
Residual voltage with Ian (10/1000) µs (line-earth) (General) ≤ 360 V
Max. operating current Imax (Connection, equipotential bonding) 3 A
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 800 V
Standards for cearances and creepage distances (Ambient conditions) IEC 60664-1
Maximum operating voltage Umax.AC (Connection, equipotential bonding) 120 V AC
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) SW Version 2.13 or later

Descrição do produto

Rail mount surge arrester for high signal voltages. Leakage current-proof protection circuit for two signals without ground potential. Rated voltage: 120 V AC
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top