Horário de atendimento: Segunda a sexta, das 9h às 18h.
PT 2X1-VF-230AC-ST - PT 2X1-VF-230AC-ST 2921365 PHOENIX CONTACT Surge protection plug
Em estoque Produto em alta

PT 2X1-VF-230AC-ST

PT 2X1-VF-230AC-ST 2921365 PHOENIX CONTACT Surge protection plug

$0.00 USD
4879 em estoque
Especificações principais
: C2
Note: 2002
Type: Male
Color: black (RAL 9005)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
C2
Note 2002
Type Male
Color black (RAL 9005)
Depth 51.7 mm
Width 17.5 mm
Height 44.8 mm
Altitude ≤ 2000 m (amsl)
Product type Surge protection for MCR technology
Screw thread M3
Mounting type on base element
Rated current 6 A
Product family PLUGTRAB PT
Open side panel No
Article revision 08
Horizontal pitch 1 Div.
Housing material PA 6.6
Response time tA ≤ 100 ns
Connection method Screw connection (in connection with the base element)
Tightening torque 0.8 Nm
Nominal voltage UN 230 V AC
Switching function N/C contact
Dimensional drawing
Direction of action Line-Line & Line-Earth Ground
Number of positions 2
Resistance per path 0 Ω
Capacity (Core-Core) typ. 1.5 pF
Degree of protection IP20
Residual current IPE ≤ 2 µA (at UN)
Capacity (Core-Earth) typ. 3 pF
Complete module depth 65.5 mm
Complete module width 17.7 mm
Complete module height 90 mm
IEC test classification C1
Standards/specifications EN 61643-21
Max. required back-up fuse 6 A (gL/gG)
Conductor cross section AWG 24 ... 12
Conductor cross section rigid 0.2 mm² ... 4 mm²
Max. energy absorption (2 ms) 150 J
Maximum continuous voltage UC 250 V AC
Surge protection fault message none
Ambient temperature (operation) -40 °C ... 80 °C
Impulse durability (line-earth) C2 - 4 kV / 2 kA
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Operating effective current ICat UC ≤ 2 µA
Max. discharge current Imax(8/20) µs 8 kA
Flammability rating according to UL 94 V-0
Nominal discharge current In(8/20) µs 3 kA
Voltage protection level Up(line-line) ≤ 2.5 kV (C2 - 4 kV / 2 kA)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Voltage protection level Up(line-earth) ≤ 1.1 kV (C1 - 500 A)
Residual voltage at In(conductor-ground) ≤ 1 kV
Pulse discharge current Iimp(10/350) µs 500 A
Total discharge current Itotal(8/20) µs 8 kA
Residual voltage at In(conductor-conductor) ≤ 2 kV
Total discharge current Itotal(10/350) µs 1 kA
Residual voltage with Ian (10/1000) µs (line-line) ≤ 1.4 kV
Nominal pulse current Ian (10/1000) µs (line-earth) 100 A
Residual voltage with Ian (10/1000) µs (line-earth) ≤ 700 V
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 1.4 kV

Descrição do produto

Plug-in protection with leakage current-proof protection circuit for two signals without earth potential. Series circuit consisting of varistor and a gas-filled surge arrester between the signal and g
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top