Horário de atendimento: Segunda a sexta, das 9h às 18h.
PT-IQ-2X2-48DC-PT - PT-IQ-2X2-48DC-PT 2801265 PHOENIX CONTACT Surge protection device
Em estoque Produto em alta

PT-IQ-2X2-48DC-PT

PT-IQ-2X2-48DC-PT 2801265 PHOENIX CONTACT Surge protection device

$0.00 USD
3082 em estoque
Especificações principais
: C2
Note: Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type: DIN rail module, two-section, divisible
Depth: 77.5 mm (incl. DIN rail 7.5 mm)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
C2
Note Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type DIN rail module, two-section, divisible
Depth 77.5 mm (incl. DIN rail 7.5 mm)
Width 17.7 mm
Height 109.3 mm
Altitude ≤ 4000 m (amsl)
Product type Surge protection for MCR technology
Mounting type DIN rail: 35 mm
Rated current 300 mA
Product family PLUGTRAB IQ
Open side panel No
Horizontal pitch 1 Div.
Housing material PA 6.6
Pollution degree 2
Connection method Push-in connection
Nominal voltage UN 48 V DC
Dimensional drawing
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path 1.2 Ω ±5 %
Capacity (Core-Core) typ. 1.5 nF
Degree of protection IP20
Overvoltage category III
Residual current IPE ≤ 2 µA (per signal circuit)
Wire pairs per module 2
IEC test classification C1
Standards/specifications IEC 61643-21
Input attenuation aE, sym. typ. 0.3 dB (≤ 450 kHz/150 Ω)
Max. required back-up fuse 315 mA (FF)
Conductor cross section AWG 24 ... 12
Response time tA(line-line) ≤ 1 ns
Pulse reset time (line-line) ≤ 300 ms
Response time tA(line-earth) ≤ 100 ns
Conductor cross section rigid 0.2 mm² ... 4 mm²
Maximum continuous voltage UC 53 V DC
Pulse reset time (line-earth) ≤ 4000 ms
Impulse durability (line-line) C1 - 1 kV / 500 A
Surge protection fault message Optical, multi-stage
Ambient temperature (operation) -40 °C ... 70 °C
Impulse durability (line-earth) C1 - 1 kV / 500 A
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Operating effective current ICat UC ≤ 5 µA (in the signal circuit)
Flammability rating according to UL 94 V-0
Voltage protection level Up(line-line) ≤ 100 V (C1 - 1 kV / 500 A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 600 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs 20 kA
Voltage protection level Upstatic (line-earth) ≤ 60 V (C2 - 10 kV / 5 kA)
Nominal discharge current In(8/20) µs (line-line) 10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 1.9 MHz
Nominal discharge current In(8/20) µs (line-ground) 10 kA
Pulse discharge current Iimp(10/350) µs (line-earth) 2.5 kA

Descrição do produto

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two 2-wire floating signal circuits. Can be used in safety-related circ
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top