Especificações principais
: blue (RAL 5015)
Note: The maximum load current of a single clamping unit must not be exceeded.
Color: multicolored
Depth: 21.7 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
blue (RAL 5015)
Note The maximum load current of a single clamping unit must not be exceeded.
Color multicolored
Depth 21.7 mm
Width 16 mm
Height 28.6 mm
Result Test passed
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Potentials 1
Pulse shape Half-sine
Acceleration 3.12g
Product type Distributor terminal block
Mounting type for snapping onto a DIN rail adapter
Specification DIN EN 50155 (VDE 0115-200):2008-03
Number of rows 1
Shock duration 18 ms
Nominal current 24 A
Nominal voltage 450 V
Open side panel No
Test directions X-, Y- and Z-axis
Article revision 00
Stripping length 8 mm ... 10 mm
Time of exposure 30 s
Cross section AWG 26 ... 12 (converted acc. to IEC)
Notes on operation the blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories
Degree of pollution 3
Insulating material PA
Rated surge voltage 6 kV
Maximum load current 32 A
Overvoltage category III
Maximum total current 48 A
Nominal cross section 2.5 mm²
Number of connections 6
Test duration per axis 5 h
Rated cross section AWG 12
Insulating material group I
Internal cylindrical gage A3
Conductor cross section rigid 0.14 mm² ... 4 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 6
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
Connection in acc. with standard IEC 60998-2-2
Permissible humidity (operation) 20 % ... 90 %
Conductor cross section, rigid [AWG] 24 ... 12 (converted acc. to IEC)
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG] 26 ... 14 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 2.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C

Descrição do produto

Distribution block, Base terminal, nominal voltage: 450 V, nominal current: 24 A, number of connections: 6, connection type: Push-in connection, cross-section: 0.14 mm² - 4 mm², mounting type: interlo
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top