PV-SET 3ST/1000DC/3MPP-SPD-SC - PV-SET 3ST/1000DC/3MPP-SPD-SC 2801531 PHOENIX CONTACT Surge protection device set
Em estoque Produto em alta

PV-SET 3ST/1000DC/3MPP-SPD-SC

PV-SET 3ST/1000DC/3MPP-SPD-SC 2801531 PHOENIX CONTACT Surge protection device set

$0.00 USD
3790 em estoque
Especificações principais
: PV T2
Note: 2011
Type: Installation housing
Depth: 142 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
PV T2
Note 2011
Type Installation housing
Depth 142 mm
Width 300 mm
Height 300 mm
Screw thread M2
Mounting type Surface/Wall mounting
Set comprises 1774674 PV-CF-S 2,5-6 (+)
Cover material Polycarbonate, transparent
Impact strength IK08
Horizontal pitch 14 Div.
Housing material Polycarbonate, glass-fiber-reinforced
Pollution degree 2
Protection class II
Response time tA ≤ 25 ns
Stripping length 7 mm
Connection method MC 1,5/3
Tightening torque 2 lbf-in. ... 4 lbf-in.
Ambient conditions A, B
Connector material PA
Nominal current IN 25 A DC (per MPP)
Switching function Changeover contact, 1-pos.
Direction of action (L+)-PE & (L-)-PE & (L+)-(L-)
Degree of protection IP65
Overvoltage category III
Residual current IPE ≤ 25 µA
Rated load current IL 80 A DC
Standards/regulations EN 50539-11
Tightening torque, min 0.25 Nm
IEC test classification PV T1
Standards/specifications IEC 61439-2
Conductor cross section AWG 30 ... 14 (UL)
Max. operating current Imax 1.5 A AC (250 V AC)
Open circuit voltage UOCSTC 830 V DC (Solar generator)
Response time tA(L+) - (L-) ≤ 25 ns
Response time tA(L+/L-) - PE ≤ 25 ns
Short-circuit current ISCSTC 25 A DC (per MPP)
Standby power consumption PC ≤ 25 mVA
Surge protection fault message optical
Ambient temperature (operation) -30 °C ... 55 °C
Recommended backup fuse maximum not required
Maximum operating voltage UmaxDC 30 V DC
Maximum operating voltage Umax.AC 250 V AC
Short-circuit current rating ISCPV 32 A DC (per MPP)
Conductor cross section, rigid max. 1.5 mm²
Conductor cross section, rigid min. 0.14 mm²
Max. backup fuse with branch wiring not required
Rated surge voltage resistance Uimp 6 kV
Conductor cross section flexible max. 1.5 mm²
Conductor cross section flexible min. 0.14 mm²
Flammability rating according to UL 94 V2 (Gehäuse / Deckel)
Nominal discharge current In(8/20) µs 15 kA
Voltage protection level Up(L+) - (L-) ≤ 3.5 kV
Voltage protection level Up(L+/L-) - PE ≤ 3.5 kV
Maximum discharge current Imax(8/20) µs 40 kA
Total discharge current Itotal(8/20) µs 40 kA
Total discharge current Itotal(10/350) µs 5 kA
Impulse discharge current (10/350) µs, peak value limp 5 kA

Descrição do produto

Lightning and surge arrester in IP65 housing for protecting the DC side of an inverter with three MPP trackers up to 1000 V DC, connection via SUNCLIX plug/socket, plug-in varistors with thermal disco
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação