Horário de atendimento: Segunda a sexta, das 9h às 18h.
RAMO-DA2AI1S-C320S1 - RAMO-DA2AI1S-C320S1 164321 EATON ELECTRIC DOL starter, Actuator output: 1, 400 V AC, 3-phase, 6.6 A, Control..
Em estoque Produto em alta

RAMO-DA2AI1S-C320S1

RAMO-DA2AI1S-C320S1 164321 EATON ELECTRIC DOL starter, Actuator output: 1, 400 V AC, 3-phase, 6.6 A, Control..

$0.00 USD
3322 em estoque
Especificações principais
Feature Name: Feature Value
Depth (EF000049): 120 mm
Width (EF000008): 220 mm
Height (EF000040): 270 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Feature Name Feature Value
Depth (EF000049) 120 mm
Width (EF000008) 220 mm
Height (EF000040) 270 mm
With fuse (EF006693) No
Release class (EF006668) CLASS 10
With transformer (EF000278) No
Type of motor starter (EF009598) Direct starter
External reset possible (EF003426) Yes
Degree of protection (IP) (EF005474) IP65
Number of indicator lights (EF001965) 0
Rated operation current Ie (EF001443) 6.6 A
Suitable for rail mounting (EF003972) No
Voltage type for actuating (EF008242) AC
With short-circuit release (EF006691) Yes
Degree of protection (NEMA) (EF011959) 12
Number of command positions (EF001372) 1
Suitable for emergency stop (EF001433) No
Supporting protocol for ASI (EF003051) Yes
Supporting protocol for CAN (EF003053) No
Supporting protocol for LON (EF003017) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for TCP/IP (EF003050) No
Rated control supply voltage DC (EF003980) 0 V
Supporting protocol for SUCONET (EF003060) No
Overload release current setting (EF002336) 0.3 A
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for PROFIsafe (EF007526) No
Rated power, 460 V, 60 Hz, 3-phase (EF009600) 2.238 kW
Rated power, 575 V, 60 Hz, 3-phase (EF009601) 0 kW
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for SafetyBUS p (EF007527) No
Rated operation power at AC-3, 400 V (EF001364) 3 kW
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET CBA (EF007524) No
Rated control supply voltage AC 50 Hz (EF003978) 0 V
Rated control supply voltage AC 60 Hz (EF003979) 0 V
Rated operation current at AC-3, 400 V (EF009602) 6.6 A
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for other bus systems (EF003062) No
Ambient temperature, upper operating limit (EF009603) 55 °C
Supporting protocol for Foundation Fieldbus (EF007522) No
Temperature compensated overload protection (EF009604) Yes
Coordination class according to IEC 60947-4-3 (EF012390) Class 1
Rated operation power at AC-3, 230 V, 3-phase (EF009599) 0 kW
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Number of auxiliary contacts as normally open contact (EF001376) 0
Rated conditional short-circuit current, type 2, 230 V (EF009606) 0 A
Rated conditional short-circuit current, type 2, 400 V (EF009605) 0 A
Number of auxiliary contacts as normally closed contact (EF001377) 0
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) 65000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) 0 A

Descrição do produto

Rapid Link 4.0; Direct motor starter; Up to 6.6 A; 400 V; 1 actuator output; With manual control switch; Braking voltage 230 V AC
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top