Horário de atendimento: Segunda a sexta, das 9h às 18h.
SAC-3P-MS/ 0,6-PUR/BI-1L-Z SCO - SAC-3P-MS/ 0,6-PUR/BI-1L-Z SCO 1435140 PHOENIX CONTACT Sensor/actuator cable
Em estoque Produto em alta

SAC-3P-MS/ 0,6-PUR/BI-1L-Z SCO

SAC-3P-MS/ 0,6-PUR/BI-1L-Z SCO 1435140 PHOENIX CONTACT Sensor/actuator cable

$17.34 USD
625 em estoque
Especificações principais
GTIN: 4046356413497
(Cable): For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey: 1435140
Catalog page: Page 234 (C-2-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356413497
(Cable) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey 1435140
Catalog page Page 234 (C-2-2017)
Packing unit 1 pc
(Dimensions) IP67
Country of origin PL (Poland)
China RoHS (Cable) Environmentally Friendly Use Period = 50
Custom tariff number 85444290
(Ambient conditions) 0.6 Nm (Valve connector)
Contact material (General) CuSn
Material, knurls (General) Zinc die-cast, nickel-plated
Sealing material (General) TPU (Seal molded)
Coding (Ambient conditions) A - standard
Torque (Ambient conditions) 0.4 Nm (M12 connector)
(Standards and Regulations) -20 °C ... 80 °C (cable, flexible installation)
Material of grip body (General) TPU
Standard designation (Material) M12 connector
Standards/regulations (Material) IEC 61076-2-101
Degree of protection (Dimensions) IP65
Contact carrier material (General) TPU GF
Contact surface material (General) Ni/Au
Rated voltage (Ambient conditions) 24 V AC
Status display (Ambient conditions) 1 LED
Reverse voltage (Ambient conditions) 50 V
Weight per Piece (excluding packing) 47.400 g
Length of cable (Key Commercial Data) 0.6 m
Material housing valve plug (General) TPU
Pulse power Wmax (Ambient conditions) 40 W (at 100 µs square-wave pulse)
Terminal voltage (Ambient conditions) 70 V (at 2 mA constant current)
Valve plug contact material (General) CuSn
Cable type (Standards and Regulations) PUR halogen-free black
Wire colors (Standards and Regulations) black 1, black 2, green/yellow
Acceleration (Standards and Regulations) 30 m/s²
Degree of pollution (Ambient conditions) 3
Halogen-free (Standards and Regulations) in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions) 3
UL AWM style (Standards and Regulations) 20549
Overall twist (Standards and Regulations) 3 wires, twisted
Overvoltage category (Ambient conditions) III
Bending radius (Standards and Regulations) 50 mm
Insulation resistance (Ambient conditions) ≥ 100 MΩ
Standards/regulations (Ambient conditions) M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations) 20
Rated current at 40°C (Ambient conditions) 4 A
Traversing path (Standards and Regulations) 0.9 m
Traversing rate (Standards and Regulations) 5 m/s
Ambient temperature (operation) (Dimensions) -25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations) according to DIN VDE 0482
Other resistance (Standards and Regulations) largely oil-resistant
Valve plug contact insert material (General) PA 6.6
Valve plug contact surface material (General) Sn
Cable abbreviation (Standards and Regulations) Li9Y11Y-HF
Conductor material (Standards and Regulations) Bare Cu litz wires
Test voltage, cable (Standards and Regulations) ≥ 1200 V
Conductor resistance (Standards and Regulations) 39 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General) HB
Insertion/withdrawal cycles (Ambient conditions) ≥ 100 (M12 connector)
Flammability rating according to UL 94 (Material) HB
Insulation resistance (Standards and Regulations) min. 20 MΩ*km
Protective circuit/component (Ambient conditions) Z diode
External sheath, color (Standards and Regulations) black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations) ≤ 300 V
Outer sheath, material (Standards and Regulations) PUR
Central screw valve connector (Key Commercial Data) M3 x 29
Conductor cross section (Standards and Regulations) 3x 0.5 mm²
Number of bending cycles (Standards and Regulations) 15000000
Cable type (abbreviation) (Standards and Regulations) PUR
External cable diameter D (Standards and Regulations) 4.5 mm ±0.2 mm
Material conductor insulation (Standards and Regulations) PP
Ambient temperature (operation) (Standards and Regulations) -40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations) 28x 0.15 mm
Core diameter including insulation (Standards and Regulations) 1.5 mm ±0.05 mm (Signal line)
Smallest bending radius, fixed installation (Standards and Regulations) 22.5 mm

Descrição do produto

Sensor/actuator cable, 3-pole halogen-free, M12 straight connector, coding: A SPEEDCON, a BI valve connectors (11mm), with 1 LED, connected with Diode Z, cable length: 0.6 m
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação