Horário de atendimento: Segunda a sexta, das 9h às 18h.
SAC-5PY-F/2X 0,3-920-MS-FS - SAC-5PY-F/2X 0,3-920-MS-FS 1436013 PHOENIX CONTACT Bus system cable
Em estoque Produto em alta

SAC-5PY-F/2X 0,3-920-MS-FS

SAC-5PY-F/2X 0,3-920-MS-FS 1436013 PHOENIX CONTACT Bus system cable

$66.50 USD
189 em estoque
Especificações principais
GTIN: 4046356428361
(Cable): For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey: 1436013
(Material): 5 (Distributor) | BU (CAN_L) | 5 (Plug) | 5 (Socket)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356428361
(Cable) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey 1436013
(Material) 5 (Distributor) | BU (CAN_L) | 5 (Plug) | 5 (Socket)
Catalog page Page 434 (C-2-2017)
Packing unit 1 pc
(Dimensions) IP67
Country of origin PL (Poland)
China RoHS (Cable) Environmentally Friendly Use Period = 50
REACh SVHC (Cable) Lead 7439-92-1
Custom tariff number 85444290
(Ambient conditions) DeviceNet™
Contact material (General) CuSn
Material, knurls (General) Zinc die-cast, nickel-plated
Sealing material (General) NBR
Coding (Ambient conditions) A - standard
Torque (Ambient conditions) 0.4 Nm (M12 connector)
(Standards and Regulations) -20 °C ... 80 °C (cable, flexible installation)
Material of grip body (General) TPU, hardly inflammable, self-extinguishing
Degree of protection (Dimensions) IP65
Contact carrier material (General) TPU GF
Contact surface material (General) Ni/Au
Rated voltage (Ambient conditions) 48 V AC
Status display (Ambient conditions) No
Weight per Piece (excluding packing) 88.800 g
Center distance (Key Commercial Data) 21 mm
Length of cable (Key Commercial Data) 0.3 m
Shielding (Standards and Regulations) Tinned copper braided shield
Standard designation (Pin assignment) M12 connector
Cable type (Standards and Regulations) CAN Bus/DeviceNet
Color handle area (Ambient conditions) black
Standards/regulations (Pin assignment) IEC 61076-2-101
Attenuation (Standards and Regulations) ≤ 22.9 dB/km (with 1 MHz)
Wire colors (Standards and Regulations) Red-black, blue-white
Acceleration (Standards and Regulations) 3 m/s²
Cable weight (Standards and Regulations) 90 kg/km
Degree of pollution (Ambient conditions) 3
Halogen-free (Standards and Regulations) in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions) 5
UL AWM style (Standards and Regulations) 21198 (80°C/300 V)
Overall twist (Standards and Regulations) 2 pairs around a drain wire in the center to the core
Overvoltage category (Ambient conditions) II
Signal type/category (Ambient conditions) CANopen®
Twisted pairs (Standards and Regulations) 2 cores to the pair
Bending radius (Standards and Regulations) 70 mm
Cable capacity (Standards and Regulations) nom. 40 nF/km (Data cable)
Insulation resistance (Ambient conditions) ≥ 100 MΩ
Standards/regulations (Ambient conditions) M12 connector IEC 61076-2-101
Wave impedance (Standards and Regulations) 120 Ω ±10 % (with 1 MHz)
AWG signal line (Standards and Regulations) 24
Cable structure (Standards and Regulations) 2xAWG24/19+2xAWG22/19
Loop resistance (Standards and Regulations) ≤ 181.80 Ω/km (Data cable)
Rated current at 40°C (Ambient conditions) 4 A
Traversing path (Standards and Regulations) 4.5 m
Traversing rate (Standards and Regulations) 3 m/s
AWG power supply (Standards and Regulations) 22
Ambient temperature (operation) (Dimensions) -25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations) UL 1581, Sec. 1060 (FT-1)
Other resistance (Standards and Regulations) Low adhesion
Conductor material (Standards and Regulations) Tin-plated Cu litz wires
Flammability rating according to UL 94 (General) HB
Insulation resistance (Standards and Regulations) ≥ 5 GΩ*km (Data cable)
External sheath, color (Standards and Regulations) violet RAL 4001
Nominal voltage, cable (Standards and Regulations) ≤ 300 V (Peak value, not for high-power applications)
Outer sheath, material (Standards and Regulations) PUR
Test voltage Core/Core (Standards and Regulations) 2000 V (50 Hz, 1 min.)
Type of pair shielding (Standards and Regulations) Plastic-coated aluminum foil, aluminum side outside
Conductor cross section (Standards and Regulations) 2x 0.25 mm² (Data cable)
Optical shield covering (Standards and Regulations) 80 %
Number of bending cycles (Standards and Regulations) 5000000
Test voltage Core/Shield (Standards and Regulations) 2000 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations) 920
External cable diameter D (Standards and Regulations) 6.7 mm ±0,3 mm
Flammability rating according to UL 94 (Pin assignment) HB
Material conductor insulation (Standards and Regulations) Foamed PE (Data cable)
Ambient temperature (operation) (Standards and Regulations) -40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations) 19x 0.13 mm
Core diameter including insulation (Standards and Regulations) 1.95 mm ±0.05 mm (Data cable)
Conductor structure, voltage supply (Standards and Regulations) 19x 0.15 mm
Contact | Color (signal designation) | Contact (optional) (Material) 1 (Distributor) | SR (shield) | 1 (Plug) | 1 (Socket)
Minimum bending radius, fixed installation (Standards and Regulations) 5 x D
Minimum bending radius, flexible installation (Standards and Regulations) 10 x D
Minimum bending radius, drag chain applications (Standards and Regulations) 10 x D

Descrição do produto

Bus System Cable, CANopen®, DeviceNet™, 5-pole halogen-free, shielded, Straight female M12, coding: A SPEEDCON, a Straight female M12, coding: A SPEEDCON and Straight connector M12, coding: A SPEEDCON
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top