SC 2,5/ 9 - SC 2,5/ 9 3041383 PHOENIX CONTACT COMBI receptacle
Em estoque Produto em alta

SC 2,5/ 9

SC 2,5/ 9 3041383 PHOENIX CONTACT COMBI receptacle

$7.17 USD
1440 em estoque
Especificações principais
: Machine building
Color: gray (RAL 7042)
Depth: 18.8 mm
Pitch: 5.2 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Machine building
Color gray (RAL 7042)
Depth 18.8 mm
Pitch 5.2 mm
Width 46.8 mm
Height 37.2 mm
Result Test passed
Spectrum Service life test category 1, class B, body mounted
ASD level 0.964 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 150 Hz
Pulse shape Half-sine
Acceleration 0.58g
Product type Terminal coupling
Specification DIN EN 50155 (VDE 0115-200):2008-03
Number of rows 1
Shock duration 30 ms
End cover width 2.2 mm
Nominal current 24 A
Nominal voltage 500 V
Open side panel Yes
Test directions X-, Y- and Z-axis
Article revision 01
Stripping length 8 mm ... 10 mm
Time of exposure 30 s
Cross section AWG 28 ... 12 (converted acc. to IEC)
Area of application Railway industry
Degree of pollution 3
Insulating material PA
Number of positions 9
Rated surge voltage 6 kV
Test force setpoint 1 N
Maximum load current 24 A (with 4 mm² conductor cross section)
Overvoltage category III
Nominal cross section 2.5 mm²
Number of connections 1
Test voltage setpoint 7.3 kV
Test duration per axis 5 h
DIN rail/fixing support Metal wall 6 mm
Insulating material group I
Internal cylindrical gage A3
Conductor cross section rigid 0.08 mm² ... 4 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C (max. operating temperature see derating curve)
Conductor cross section flexible 0.08 mm² ... 2.5 mm²
Connection in acc. with standard IEC 61984
Permissible humidity (operation) 20 % ... 90 %
Short-time withstand current 2.5 mm² 0.3 kA
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG] 28 ... 14 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 2.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm²

Descrição do produto

COMBI coupling, nominal voltage: 500 V, nominal current: 24 A, number of connections: 1, number of poles: 9, connection type: Spring connection, Sizing cross-section: 2.5 mm², cross-section: 0.08 mm²
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação