ST 4-HEDI - ST 4-HEDI 3035140 PHOENIX CONTACT Lever-type disconnect terminal block
Em estoque Produto em alta

ST 4-HEDI

ST 4-HEDI 3035140 PHOENIX CONTACT Lever-type disconnect terminal block

$5.08 USD
2002 em estoque
Especificações principais
: Machine building
Color: multicolored
Width: 6.2 mm
Height: 61.5 mm
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Machine building
Color multicolored
Width 6.2 mm
Height 61.5 mm
Result Test passed
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Potentials 1
Pulse shape Half-sine
Revolutions 135
Acceleration 3.12g
Product type Disconnect terminal block
Mounting type NS 35/7,5
Specification DIN EN 50155 (VDE 0115-200):2008-03
Number of rows 1
Rotation speed 10 rpm
Shock duration 18 ms
Nominal current 20 A (with 6 mm² conductor cross section)
Nominal voltage 500 V
Open side panel No
Test directions X-, Y- and Z-axis
Article revision 06
Stripping length 8 mm ... 10 mm
Time of exposure 30 s
Cross section AWG 28 ... 10 (converted acc. to IEC)
Depth on NS 35/15 70 mm
Temperature cycles 192
Area of application Railway industry
Degree of pollution 3
Depth on NS 35/7,5 62.5 mm
Insulating material PA
Rated surge voltage 6 kV
Test force setpoint 1 N
Maximum load current 20 A (with 6 mm² conductor cross section)
Overvoltage category III
Nominal cross section 4 mm²
Number of connections 2
Test voltage setpoint 7.3 kV
Test duration per axis 5 h
DIN rail/fixing support NS 35
Insulating material group I
Internal cylindrical gage A4
Conductor cross section rigid 0.08 mm² ... 6 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Conductor cross section/weight 0.08 mm² / 0.1 kg
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 0.08 mm² ... 4 mm²
Connection in acc. with standard IEC 60947-7-1
Permissible humidity (operation) 20 % ... 90 %
Requirement temperature-rise test Increase in temperature ≤ 45 K
Short-time withstand current 2.5 mm² 0.3 kA
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 28 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 1.02 W
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 1 mm²

Descrição do produto

Lever-interruptible terminal block, nominal voltage: 500 V, nominal current: 20 A, connection type: Spring connection, Dimensioning cross-section: 4 mm², cross-section: 0.08 mm² - 6 mm², mounting: NS
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação