Horário de atendimento: Segunda a sexta, das 9h às 18h.
TRIO-PS/3AC/24DC/ 5 - TRIO-PS/3AC/24DC/ 5 2866462 PHOENIX CONTACT Power supply unit
Em estoque Produto em alta

TRIO-PS/3AC/24DC/ 5

TRIO-PS/3AC/24DC/ 5 2866462 PHOENIX CONTACT Power supply unit

$0.00 USD
3238 em estoque
Especificações principais
GTIN: 4046356128544
Note: Made to Order (non-returnable)
Orderkey: 2866462
(Signaling): 15 Hz ... 150 Hz, 2.3g, 90 min.
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4046356128544
Note Made to Order (non-returnable)
Orderkey 2866462
(Signaling) 15 Hz ... 150 Hz, 2.3g, 90 min.
Catalog page Page 176 (C-6-2013)
Packing unit 1 pc
(Input data) < 0.1 % (change in input voltage ±10 %)
(Output data) 2 kV AC (routine test)
Country of origin CN (China)
Shock (Signaling) 15g in all directions in acc. with IEC 60068-2-27
Voltage (Signaling) 10 V (Test Level 3)
Comments (Signaling) Criterion B
Custom tariff number 85044030
(Ambient conditions) > 30 ms (3x 480 V AC)
Derating (Input data) 55 °C ... 70 °C (2.5%/K)
Screw thread (General) M2,5
Efficiency (Output data) 89 % (at 400 V AC and nominal values)
Net weight (Output data) 0.6 kg
UL approvals (Signaling) UL/C-UL listed UL 508
Output power (Input data) 120 W
Noise immunity (Signaling) EN 61000-6-2:2005
Stripping length (General) 9 mm
Climatic class (Dimensions) 3K3 (in acc. with EN 60721)
Connection method (General) Screw connection
Depth (Key Commercial Data) 115 mm
Frequency range (Signaling) 0.15 MHz ... 80 MHz
Width (Key Commercial Data) 40 mm
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data) 130 mm
Residual ripple (Input data) < 30 mVPP
Contact discharge (Signaling) 4 kV (Test Level 2)
Control deviation (Input data) < 1 % (change in load, static 10 % ... 90 %)
Protection class (Output data) I (with PE connection)
Mounting position (Output data) horizontal DIN rail NS 35, EN 60715
Test field strength (Signaling) 3 V/m
Degree of pollution (Dimensions) 2
Feedback resistance (Input data) 35 V DC
Connection in series (Input data) yes
Degree of protection (Dimensions) IP20
Low Voltage Directive (Signaling) Conformance with LV directive 2006/95/EC
Max. capacitive load (Input data) unlimited
Standards/regulations (Signaling) EN 61000-4-11
Vibration (operation) (Signaling) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Degree of protection (Output data) IP20
Typical response time (Input data) < 1 s
Assembly instructions (Output data) alignable: horizontally 0 mm, vertically 50 mm
Connection in parallel (Input data) Yes, for redundancy and increased capacity
Nominal output voltage (Input data) 24 V DC ±1 %
Mains buffering (Ambient conditions) > 20 ms (3x 400 V AC)
Weight per Piece (excluding packing) 600.000 g
Screw thread (Connection data, input) M2,5
Standard - Safe isolation (Signaling) DIN VDE 0100-410
Active current limitation (Input data) Approx 6 A (in the event of a short-circuit)
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 25;
AC frequency range (Ambient conditions) 45 Hz ... 65 Hz
Operating voltage display (Output data) Green LED
Type of protection (Ambient conditions) Transient surge protection
Current consumption (Ambient conditions) 3x 0.3 A (400 V AC)
Input voltage range (Ambient conditions) 3x 320 V AC ... 575 V AC (for 3-phase operation)
MTBF (IEC 61709, SN 29500) (Output data) > 1474000 h
Nominal output current (IN) (Input data) 5 A (UOUT= 24 V DC)
Standard - Electrical safety (Signaling) EN 60950-1/VDE 0805 (SELV)
Status display (Connection data, output) "DC OK" LED green
Electromagnetic compatibility (Signaling) Conformance with EMC Directive 2014/30/EU
Inrush surge current (Ambient conditions) < 15 A
Power loss nominal load max. (Input data) 15 W
Stripping length (Connection data, input) 9 mm
Conductor cross section AWG max. (General) 14
Conductor cross section AWG min. (General) 24
Connection method (Connection data, input) Screw connection
Output overvoltage protection (Input data) < 35 V DC
Insulation voltage input / PE (Output data) 2 kV AC (type test)
Power factor (cos phi) (Ambient conditions) 0.64
Ambient temperature (operation) (Dimensions) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Conductor cross section solid max. (General) 2.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Connection in acc. with standard (Signaling) CUL
Discharge current to PE (Ambient conditions) < 3.5 mA
Insulation voltage output / PE (Output data) 500 V DC (routine test)
Insulation voltage input/output (Output data) 4 kV AC (type test)
Nominal power consumption (Ambient conditions) 211 VA
Conductor cross section flexible max. (General) 2.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Nominal input voltage range (Ambient conditions) 2x / 3x 400 V AC ... 500 V AC
Note on status display (Connection data, output) UOUT> 21.5 V: LED lights up
Peak switching voltages nominal load (Input data) < 30 mVPP
Protective circuit/component (Ambient conditions) Varistor
Standard – Safety extra-low voltage (Signaling) EN 60950-1 (SELV)
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Setting range of the output voltage (USet) (Input data) 22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Choice of suitable circuit breakers (Ambient conditions) 6 A ... 16 A (Characteristics B, C, D, K)
Conductor cross section AWG max. (Connection data, input) 12
Conductor cross section AWG min. (Connection data, input) 16
Conductor cross section solid max. (Connection data, input) 2.5 mm²
Conductor cross section solid min. (Connection data, input) 0.2 mm²
Max. permissible relative humidity (operation) (Dimensions) ≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data) 4 W
Conductor cross section flexible max. (Connection data, input) 2.5 mm²
Conductor cross section flexible min. (Connection data, input) 0.2 mm²
Standard – Limitation of mains harmonic currents (Signaling) EN 61000-3-2
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Signaling) EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Signaling) EN 50178/VDE 0160 (PELV)

Descrição do produto

TRIO POWER primary switching power supply for rail mounting, input: three-phase, output: 24 V DC/5 A
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação