Especificações principais
: 21 V AC
Note: 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Type: DIN rail module, one-piece
Color: gray (RAL 7042)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
21 V AC
Note 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Type DIN rail module, one-piece
Color gray (RAL 7042)
Depth 69.5 mm (incl. DIN rail 7.5 mm)
Width 6.2 mm
Height 92 mm
Altitude ≤ 4000 m (amsl)
Product type Surge protection for MCR technology
Screw thread M3
Mounting type DIN rail: 35 mm
Rated current 10 A (60 °C)
Product family TERMITRAB complete
Open side panel Yes
Article revision 08
Housing material PBT
Pollution degree 2
Connection method Screw connection
Tightening torque 0.5 Nm ... 0.6 Nm
Nominal voltage UN 24 V DC
Dimensional drawing
Direction of action Line-Earth Ground
Insulating material PBT
Resistance per path ≤ 100 mΩ
Degree of protection IP20 (with end cover)
Overvoltage category III
Residual current IPE ≤ 5 µA
Capacity (Core-Earth) 1.5 nF
IEC test classification C3
Standards/specifications IEC 61643-21
Conductor cross section AWG 24 ... 12
Input attenuation aE, asym. typ. 0.3 dB (≤ 520 kHz/150 Ω)
Response time tA(line-earth) ≤ 1 ns
Conductor cross section rigid 0.2 mm² ... 4 mm²
Maximum continuous voltage UC 30 V DC
Surge protection fault message optical
Ambient temperature (operation) -40 °C ... 85 °C
Impulse durability (line-earth) C3 - 30 A
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Permissible humidity (operation) 5 % ... 95 %
Operating effective current ICat UC ≤ 5 µA
Flammability rating according to UL 94 V-0
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 50 V (C3 - 25 A)
Nominal discharge current In(8/20) µs (line-ground) 150 A
Cut-off frequency fg (3 dB), asym. (PE) in 150 Ω system typ. 1.7 MHz

Descrição do produto

Fine surge protection with integrated status indication for a grounded signal conductor with reference potential.