Horário de atendimento: Segunda a sexta, das 9h às 18h.
UDP102ZL3MP - UDP102ZL3MP DP-102ZL3-M-P PANASONIC Pressure sensor, -1 to 10bar, IO Link, pressure connector short M5 femal..
Em estoque Produto em alta

UDP102ZL3MP

UDP102ZL3MP DP-102ZL3-M-P PANASONIC Pressure sensor, -1 to 10bar, IO Link, pressure connector short M5 femal..

$0.00 USD
4126 em estoque
Especificações principais
Item: Specifications
Remark: (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
Weight: Net weight: 30 g approx., Gross weight: 125 g approx.
Details: Discrete wire type
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Item Specifications
Remark (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
Weight Net weight: 30 g approx., Gross weight: 125 g approx.
Details Discrete wire type
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Product Dual Display Digital Pressure Sensor [For Gas]
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Protection IP40(IEC)
Accessories CN-14A-C2 (Connector attached cable 2 m6.562 ft): 1 pc.
Part Number DP-102ZL3-M-P
Cable length Total length up to 20 m65.617 ft(Condition of CE compliance less than 20 m65.617 ft)is possible with 0.3 mm2, or more, cable.
Product name Dual Display Digital Pressure Sensor [For Gas] DP-100L
Pressure port M5 female thread
Product Number DP-102ZL3-M-P
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Applicable fluid Non-corrosive gas
Output indicator Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2)Output operation indicator 2: Lights up when the control output is ON)
Shock resistance 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
Type of pressure Gauge pressure
Connecting method Connector
Power consumption Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
Set pressure range -0.101 to +1.010MPa
Ambient temperature -10 to +50℃+14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃+14 to +140 ℉
Control output (DO) PNP open-collector transistor•Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 50 mA source current)
Rated pressure range -0.100 to +1.000 Mpa
Vibration resistance 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Insulation resistance 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Pressure withstandability 1.5MPa
Temperature characteristics Within ±1 % F.S.(at +20℃+68℉)
Control output (DO):Hysteresis Minimum 1 digit (variable)
Control output (DO):Repeatability ±0.2 % F.S. (within ±2 digits)
Control output (DO):Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Display:Displayable pressure range -0.101 to +1.010MPa
Communication output (C/Q):Baud rate COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Control output (DO):Output operation N.O./N.C. (selectable by key operation)
Communication output (C/Q):Process data 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Regulatory compliance and certification CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification
Control output (DO):Short-circuit protection Incorporated
Communication output (C/Q):Minimum cycle time 1.0ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Communication output (C/Q):IO-Link communication IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Control output (DO):Output operationOutput modes EASY mode / Hysteresis mode / Window comparator mode

Descrição do produto

DP-100L Series. Digital pressure controller, -1 to 10bar, short M5 female threaded pressure port, 2m cable, IO Link connection, PNP
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top