Horário de atendimento: Segunda a sexta, das 9h às 18h.
UHGTC101P - UHGTC101P HG-TC101-P PANASONIC HG-T Laser Sensor Displacement. Master controller high-functionality, PNP out..
Em estoque Produto em alta

UHGTC101P

UHGTC101P HG-TC101-P PANASONIC HG-T Laser Sensor Displacement. Master controller high-functionality, PNP out..

$0.00 USD
4704 em estoque
Especificações principais
: When communication unitis connected
Item: Specifications
Cable: 0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
Details: Master unit / High performance type
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
When communication unitis connected
Item Specifications
Cable 0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
Details Master unit / High performance type
Product Controller
Material Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight 140 g approx.
Part Number HG-TC101-P
1 to 7 units 1 to 6 units
Product name Thru-beam Type Digital Displacement Sensor HG-T
8 to 15 units 7 to 14 units
Display range -199.999 to 199.999 mm-7.874 to 7.874 in
Sampling rate 1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Product Number HG-TC101-P
Supply voltage 24 V DC ±10 %, including ripple 0.5 V (P-P)
Pollution degree 2
Display resolution 1 μm0.039 mil
Operating altitude 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Current consumption 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output.
Regulatory compliance CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Applicable sensor head HG-T1010、HG-T1110
External input switching Input 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
External output switching Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
Average count (response time) 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Number of connected slave units Maximum sink current and sourcecurrent of control output
Interference prevention function Incorporated(Note) : This function operates for each set of 4 connected controllers.
Environmental resistance : Protection IP40(IEC)
Analogue output : Analog current output •Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Analogue output : Analog voltage output •Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
External input(Input 1, Input 2, Input 3) Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx.
Maximum number of connectable controllers Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Environmental resistance : Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Shock resistance 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Control output(Output 1, Output 2, Output 3) NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Environmental resistance : Ambient temperature -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Environmental resistance : Vibration resistance 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Environmental resistance : Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental resistance : Voltage withstandability 1,000 V AC for one minute between all supply terminals connected together and enclosure
External input(Input 1, Input 2, Input 3) : Input time • Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Control output(Output 1, Output 2, Output 3) : Alarm output Open when alarm occurs
Control output(Output 1, Output 2, Output 3) : Judgment output N.O. / N.C. switching type
Control output(Output 1, Output 2, Output 3) : Short-circuit protection Incorporated (automatic reset type)

Descrição do produto

HG-T Laser Displacement Sensor. High Functionality Master Controller, PNP Output
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top