Horário de atendimento: Segunda a sexta, das 9h às 18h.
UHV 95-KH/AS - UHV 95-KH/AS 2130127 PHOENIX CONTACT High Current Connectors
Em estoque Produto em alta

UHV 95-KH/AS

UHV 95-KH/AS 2130127 PHOENIX CONTACT High Current Connectors

$0.00 USD
3491 em estoque
Especificações principais
GTIN: 4017918052904
Orderkey: 2130127
Catalog page: Page 555 (C-1-2017)
Packing unit: 10 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918052904
Orderkey 2130127
Catalog page Page 555 (C-1-2017)
Packing unit 10 pc
Width (General) 40 mm
Length (General) 114 mm
Country of origin IN (India)
(Connection data) IEC 60947-7-1
Custom tariff number 85369010
(Key Commercial Data) 95 mm²/14 kg
Power rail (Dimensions) 30 mm x 5 mm
Height NS 35/15 (General) 86 mm
Screw thread (Dimensions) M8
Bolt diameter (Dimensions) 12 mm
Color (Key Commercial Data) gray
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Stripping length (Dimensions) 29 mm
Connection method (Dimensions) Screw connection
Setpoint (Key Commercial Data) 15 N
Hole diameter, min. (Dimensions) 13 mm
Tightening torque max (Dimensions) 20 Nm
Tightening torque, min (Dimensions) 15 Nm
Weight per Piece (excluding packing) 296.230 g
Open side panel (Key Commercial Data) No
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Number of levels (Key Commercial Data) 1
Nominal current IN (Key Commercial Data) 232 A
Nominal voltage UN (Key Commercial Data) 1000 V
Short-time current (Key Commercial Data) 11.4 kA
Degree of pollution (Key Commercial Data) 3
Insulating material (Key Commercial Data) PA-F
Rated surge voltage (Key Commercial Data) 8 kV
Tensile test result (Key Commercial Data) Test passed
Maximum load current (Key Commercial Data) 232 A (with 95 mm2conductor cross section)
Overvoltage category (Key Commercial Data) III
Tight fit on carrier (Key Commercial Data) NS 32/NS 35
Nominal cross section (Key Commercial Data) 95 mm²
Number of connections (Key Commercial Data) 2
Result of bending test (Key Commercial Data) Test passed
Result of thermal test (Key Commercial Data) Test passed
Conductor cross section AWG max. (Dimensions) 3/0
Conductor cross section AWG min. (Dimensions) 3
Tractive force setpoint (Key Commercial Data) 351 N
Conductor cross section solid max. (Dimensions) 95 mm²
Conductor cross section solid min. (Dimensions) 25 mm²
Insulating material group (Key Commercial Data) II
Requirements, voltage drop (Key Commercial Data) U1≤ 3.2 mV
Result of voltage-drop test (Key Commercial Data) Test passed
Surge voltage test setpoint (Key Commercial Data) 9.8 kV
Conductor cross section flexible max. (Dimensions) 95 mm²
Conductor cross section flexible min. (Dimensions) 35 mm²
Connection in acc. with standard (Connection data) CSA
Result of surge voltage test (Key Commercial Data) Test passed
Result of tight fit on support (Key Commercial Data) Test passed
Short circuit stability result (Key Commercial Data) Test passed
Nominal current IN(upper level) (Key Commercial Data) 232 A
Result of temperature-rise test (Key Commercial Data) Test passed
Connection in acc. with standard (Key Commercial Data) IEC 60947-7-1
Cable lug connection according to standard (Dimensions) DIN 46235
Flammability rating according to UL 94 (Connection data) V0
Max. cross section for cable lug connection (Dimensions) 95 mm²
Maximum load current (upper level) (Key Commercial Data) 232 A (with 95 mm2conductor cross section)
Min. cross section for cable lug connection (Dimensions) 25 mm²
Conductor cross section tensile test (Key Commercial Data) 95 mm²
Flammability rating according to UL 94 (Key Commercial Data) V0
2 conductors with same cross section, solid max. (Dimensions) 35 mm²
2 conductors with same cross section, solid min. (Dimensions) 25 mm²
2 conductors with same cross section, stranded max. (Dimensions) 35 mm²
2 conductors with same cross section, stranded min. (Dimensions) 25 mm²
Power frequency withstand voltage setpoint (Key Commercial Data) 2.2 kV
Bending test conductor cross section/weight (Key Commercial Data) 25 mm² / 4.5 kg
Conductor cross section short circuit testing (Key Commercial Data) 95 mm²
Maximum power dissipation for nominal condition (Key Commercial Data) 7.54 W
Result of power-frequency withstand voltage test (Key Commercial Data) Test passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) 95 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) 35 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) 120 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) 95 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) 35 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data) 30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) 125 °C
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions) 35 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions) 16 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data) Test passed

Descrição do produto

Universal terminal block with mixed connection, cross-section: 35 - 95 mm², AWG: 2 - 4/0, width: 40 mm, colour: Grey
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top