UIK 35 BU - UIK 35 BU 3006302 PHOENIX CONTACT Installation terminal block
Em estoque Produto em alta

UIK 35 BU

UIK 35 BU 3006302 PHOENIX CONTACT Installation terminal block

$6.89 USD
1482 em estoque
Especificações principais
GTIN: 4017918091477
Orderkey: 3006302
Catalog page: Page 505 (C-1-2017)
Packing unit: 50 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918091477
Orderkey 3006302
Catalog page Page 505 (C-1-2017)
Packing unit 50 pc
Width (General) 15.2 mm
Length (General) 55 mm
Country of origin CN (China)
Note (Dimensions) Terminal point
(Connection data) IEC 60947-7-1
Custom tariff number 85369010
(Key Commercial Data) 35 mm² / 6.8 kg
Height NS 32 (General) 56 mm
Height NS 35/15 (General) 58.5 mm
Screw thread (Dimensions) M6
Height NS 35/7,5 (General) 51 mm
Color (Key Commercial Data) blue
(Standards and Regulations) No hazardous substances above threshold values
Stripping length (Dimensions) 16 mm
Connection method (Dimensions) Screw connection
Setpoint (Key Commercial Data) 10 N
Tightening torque max (Dimensions) 3.7 Nm
Tightening torque, min (Dimensions) 3.2 Nm
Weight per Piece (excluding packing) 44.100 g
Open side panel (Key Commercial Data) No
China RoHS (Standards and Regulations) Environmentally friendly use period: unlimited = EFUP-e
Number of levels (Key Commercial Data) 1
Bending test turns (Key Commercial Data) 135
Nominal current IN (Key Commercial Data) 125 A
Nominal voltage UN (Key Commercial Data) 800 V
Short-time current (Key Commercial Data) 4.2 kA
Degree of pollution (Key Commercial Data) 3
Insulating material (Key Commercial Data) PA
Rated surge voltage (Key Commercial Data) 8 kV
Tensile test result (Key Commercial Data) Test passed
Maximum load current (Key Commercial Data) 125 A (with 35 mm² conductor cross section)
Overvoltage category (Key Commercial Data) III
Tight fit on carrier (Key Commercial Data) NS 32/NS 35
Nominal cross section (Key Commercial Data) 35 mm²
Number of connections (Key Commercial Data) 2
Result of bending test (Key Commercial Data) Test passed
Result of thermal test (Key Commercial Data) Test passed
Conductor cross section AWG max. (Dimensions) 2
Conductor cross section AWG min. (Dimensions) 18
Tractive force setpoint (Key Commercial Data) 190 N
Conductor cross section solid max. (Dimensions) 35 mm²
Conductor cross section solid min. (Dimensions) 0.75 mm²
Insulating material group (Key Commercial Data) I
Requirements, voltage drop (Key Commercial Data) ≤ 3.2 mV
Back of the hand protection (Key Commercial Data) guaranteed
Bending test rotation speed (Key Commercial Data) 10 rpm
Result of voltage-drop test (Key Commercial Data) Test passed
Surge voltage test setpoint (Key Commercial Data) 9.8 kV
Conductor cross section flexible max. (Dimensions) 35 mm²
Conductor cross section flexible min. (Dimensions) 0.75 mm²
Connection in acc. with standard (Connection data) CUL
Result of surge voltage test (Key Commercial Data) Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data) 2
NF F16-101, NF F10-102 Class I (Key Commercial Data) 2
Result of tight fit on support (Key Commercial Data) Test passed
Short circuit stability result (Key Commercial Data) Test passed
Result of temperature-rise test (Key Commercial Data) Test passed
Connection in acc. with standard (Key Commercial Data) IEC 60947-7-1
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data) >32 %
Flammability rating according to UL 94 (Connection data) V2
Shock protection test specification (Key Commercial Data) IEC 60529:2001-02
Conductor cross section tensile test (Key Commercial Data) 35 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data) V0
Flammability rating according to UL 94 (Key Commercial Data) V2
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data) passed
2 conductors with same cross section, solid max. (Dimensions) 10 mm²
2 conductors with same cross section, solid min. (Dimensions) 0.75 mm²
2 conductors with same cross section, stranded max. (Dimensions) 10 mm²
2 conductors with same cross section, stranded min. (Dimensions) 0.75 mm²
Power frequency withstand voltage setpoint (Key Commercial Data) 2 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data) passed
Bending test conductor cross section/weight (Key Commercial Data) 0.75 mm² / 0.4 kg
Conductor cross section short circuit testing (Key Commercial Data) 35 mm²
Static insulating material application in cold (Key Commercial Data) -60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data) Test passed
Maximum power dissipation for nominal condition (Key Commercial Data) 4.06 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data) 28 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data) Test passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data) HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data) passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) 35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) 0.75 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) 130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) 35 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) 0.75 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data) 30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) 130 °C
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions) 10 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions) 0.75 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) 6 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) 0.75 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data) Test passed

Descrição do produto

Terminal block, nominal voltage: 800 V, nominal current: 125 A, Screw connection, Dimensioning cross-section: 35 mm², cross-section: 0.75 mm² - 35 mm², installation class: NS 35/7.5, NS 35/15, NS 32,