UK 10-PLUS - UK 10-PLUS 3001381 PHOENIX CONTACT Feed-through terminal block
Em estoque Produto em alta

UK 10-PLUS

UK 10-PLUS 3001381 PHOENIX CONTACT Feed-through terminal block

$4.68 USD
2174 em estoque
Especificações principais
GTIN: 4017918089870
Orderkey: 3001381
Catalog page: Page 429 (C-1-2017)
Packing unit: 50 pc
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4017918089870
Orderkey 3001381
Catalog page Page 429 (C-1-2017)
Packing unit 50 pc
Width (General) 10.2 mm
Length (General) 53 mm
Country of origin PL (Poland)
Note (Dimensions) Feed-through
(Connection data) IEC 60947-7-1
Custom tariff number 85369010
(Key Commercial Data) 16 mm² / 2.9 kg
Height NS 32 (General) 52 mm
Height NS 35/15 (General) 54.5 mm
Screw thread (Dimensions) M3
Height NS 35/7,5 (General) 47 mm
Color (Key Commercial Data) gray
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Stripping length (Dimensions) 7 mm
Connection method (Dimensions) Screw connection
Setpoint (Key Commercial Data) 5 N
Potentials (Key Commercial Data) 1
Tightening torque max (Dimensions) 0.8 Nm
Tightening torque, min (Dimensions) 0.6 Nm
Weight per Piece (excluding packing) 21.530 g
Open side panel (Key Commercial Data) No
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Number of levels (Key Commercial Data) 2
Finger protection (Key Commercial Data) guaranteed
Bending test turns (Key Commercial Data) 135
Nominal current IN (Key Commercial Data) 32 A (with 6 mm² conductor cross section)
Nominal voltage UN (Key Commercial Data) 800 V
Short-time current (Key Commercial Data) 0.48 kA
Degree of pollution (Key Commercial Data) 3
Insulating material (Key Commercial Data) PA
Rated surge voltage (Key Commercial Data) 8 kV
Tensile test result (Key Commercial Data) Test passed
Maximum load current (Key Commercial Data) 41 A (In the case of a 6 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors)
Overvoltage category (Key Commercial Data) III
Tight fit on carrier (Key Commercial Data) NS 32/NS 35
Nominal cross section (Key Commercial Data) 10 mm²
Number of connections (Key Commercial Data) 3
Result of bending test (Key Commercial Data) Test passed
Result of thermal test (Key Commercial Data) Test passed
Conductor cross section AWG max. (Dimensions) 10
Conductor cross section AWG min. (Dimensions) 24
Connection in acc. with standard (Dimensions) IEC 60947-7-1
Tractive force setpoint (Key Commercial Data) 80 N
Conductor cross section solid max. (Dimensions) 6 mm²
Conductor cross section solid min. (Dimensions) 0.2 mm²
Insulating material group (Key Commercial Data) I
Requirements, voltage drop (Key Commercial Data) ≤ 3.2 mV
Back of the hand protection (Key Commercial Data) guaranteed
Bending test rotation speed (Key Commercial Data) 10 rpm
Result of voltage-drop test (Key Commercial Data) Test passed
Surge voltage test setpoint (Key Commercial Data) 9.8 kV
Conductor cross section flexible max. (Dimensions) 4 mm²
Conductor cross section flexible min. (Dimensions) 0.2 mm²
Connection in acc. with standard (Connection data) CSA
Result of surge voltage test (Key Commercial Data) Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data) 2
NF F16-101, NF F10-102 Class I (Key Commercial Data) 2
Result of tight fit on support (Key Commercial Data) Test passed
Short circuit stability result (Key Commercial Data) Test passed
Result of temperature-rise test (Key Commercial Data) Test passed
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data) >32 %
Max. AWG conductor cross section, flexible (Dimensions) 8
Min. AWG conductor cross section, flexible (Dimensions) 20
Flammability rating according to UL 94 (Connection data) V0
Shock protection test specification (Key Commercial Data) IEC 60529:2001-02
Conductor cross section tensile test (Key Commercial Data) 6 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data) V0
Flammability rating according to UL 94 (Key Commercial Data) V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data) passed
2 conductors with same cross section, solid max. (Dimensions) 1.5 mm²
2 conductors with same cross section, solid min. (Dimensions) 0.2 mm²
2 conductors with same cross section, stranded max. (Dimensions) 1.5 mm²
2 conductors with same cross section, stranded min. (Dimensions) 0.2 mm²
Power frequency withstand voltage setpoint (Key Commercial Data) 2 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data) passed
Bending test conductor cross section/weight (Key Commercial Data) 0.2 mm² / 0.2 kg
Conductor cross section short circuit testing (Key Commercial Data) 4 mm²
Static insulating material application in cold (Key Commercial Data) -60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data) Test passed
Maximum power dissipation for nominal condition (Key Commercial Data) 1.82 W (the value is multiplied when connecting multiple levels)
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data) 28 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data) Test passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data) HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data) passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) 4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) 0.25 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) 130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) 0.25 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data) 30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) 130 °C
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions) 1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions) 0.25 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) 1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) 0.5 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data) Test passed

Descrição do produto

1-story terminal block with double connection on one side, cross-section: 0.5 - 10 mm², AWG: 24 - 6, width: 10.2 mm, colour: Grey
Principais características