USGB1SAG5 - USGB1SAG5 SG-B1-SA-G5 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Spring lock, 5m cab..
Em estoque Produto em alta

USGB1SAG5

USGB1SAG5 SG-B1-SA-G5 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Spring lock, 5m cab..

$0.00 USD
3449 em estoque
Especificações principais
: Ue
DC: Resistive load (DC-12)
Ie: Main circuit, look monitor circuit
B10D: 2,000,000(ISO 13849-1 Annex C Table C.1)
Informações do fornecedor
PANASONIC
PANASONIC
Produtos: 4316
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
Ue
DC Resistive load (DC-12)
Ie Main circuit, look monitor circuit
B10D 2,000,000(ISO 13849-1 Annex C Table C.1)
Item Specifications
Cable UL style 2464, No.22 AWG 12-core
Weight Approx. 600 g
Details Spring lock type
Product Ultra-slim Safety door switch with solenoid interlock
Material Enclosure : PA66
Protection IP 67 (IEC 60529)
Part Number SG-B1-SA-G5
Cable length 5m16.404 ft
Product name Ultra-slim Safety door switch with solenoid interlock SG-B1
Main contacts 1NC + 1NC
Product Number SG-B1-SA-G5
Interlock force 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
Shock resistance Malfunction : 100 m/s2, Destruction : 1,000 m/s2
Contact resistance 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable)
Operating frequency 900 operations/hour
Applicable standards EN 60947-5-1, GS-ET-19
Direct opening force 60 N min.
Door monitor circuit AC
Vibration resistance Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in
Direct opening travel 8 mm0.315 inmin.
Door monitor contacts 2NC
Electrical durability 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load)
Lock monitor contacts 1NC
Mechanical durability 1,000,000 operations min. (GS-ET-19)
Thermal current (Ith) ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits)
Applicable regulations CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Inductive load (AC-15) -
Inductive load (DC-13) 1A
Actuator operating speed 0.05 to 1.0 m/sec.
Rated insulation voltage (Ui) 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit)
Operating condition : Altitude 2,000 m6,561.68 ftmax.
Electric shock protection class Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
Short-circuit protective device Use 250 V / 10 A fast acting type fuse
Impulse withstand voltage (Uimp) 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit)
Solenoid / Indicator : Indicator Green LED
Solenoid / Indicator : Rated current 110 mA (solenoid 100 mA, LED 10 mA : initial value)
Operating condition : Ambient humidity 45 to 85 % RH
Operating condition : Pollution degree 3 (Inside 2)
Solenoid / Indicator : Turn on voltage Rated voltage × 85 % max. (at 20 ℃68 ℉)
Solenoid / Indicator : Turn off voltage Rated voltage × 10 % min. (at 20 ℃68 ℉)
Applicable standards : Standards for use IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Operating condition : Ambient temperature -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉
Solenoid / Indicator : Rated operating voltage DC 24 V 100% duty cycle
Rated operational voltage (Ue) / Rated operational current (Ie) Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A

Descrição do produto

Safety limit switch (Ultra-narrow) for door with magnetic interconnection, spring lock, 5m cable, main 1NC+1NC, Monitor 2NC+1NC
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação