Especificações principais
GTIN: 4055626063003
Note: Made to Order (non-returnable)
Orderkey: 2906292
(General): ≤ 3.6 kV (at 40 kA)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626063003
Note Made to Order (non-returnable)
Orderkey 2906292
(General) ≤ 3.6 kV (at 40 kA)
Catalog page Page 41 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
Custom tariff number 85363030
(Ambient conditions) (L-) - PE
Altitude (Dimensions) ≤ 6000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, one-piece
Color (Ambient conditions) traffic grey A RAL 7042
Response time tA (General) ≤ 25 ns
Depth (Key Commercial Data) 65.5 mm
Width (Key Commercial Data) 71.2 mm
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 120 mm
Residual current IPE (General) ≤ 45 µA DC
Shock (operation) (Dimensions) 50g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 50 A
Residual voltage Ures (General) ≤ 2.9 kV (at In)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Accessibility (Ambient conditions) Accessible
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 5g (5 - 500 Hz/2.5 h/X, Y, Z)
Insulation resistance Riso (General) > 5 GΩ (at 500 V DC)
Weight per Piece (excluding packing) 321.450 g
Housing material (Ambient conditions) PA 6.6
Voltage protection level Up (General) ≤ 2.9 kV
Horizontal pitch (Key Commercial Data) 4 Div.
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Standby power consumption PC (General) ≤ 36 mVA
Mode of protection (Ambient conditions) (L+) - (L-)
Standards/regulations (Connection data) EN 50539-11 2013
Degree of pollution (Ambient conditions) 2
SPD failure behavior (Ambient conditions) OCM (Open-circuit mode)
Screw thread (Indicator/remote signaling) M5
(Protective circuit DC voltage side (DC)) 5 mA DC ... 1 A DC
Installation location (Ambient conditions) Inside
Continuous operating current ICPV (General) < 45 µA
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) DC
IEC test classification (Ambient conditions) PV I / II
Short-circuit current rating ISCPV (General) 2000 A
Connection configuration (Ambient conditions) Y configuration
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Screw connection
Nominal discharge current (8/20) µs (General) 20 kA
Tightening torque (Indicator/remote signaling) 3 Nm
Maximum discharge current Imax(8/20) µs (General) 40 kA
Total discharge current Itotal(8/20) µs (General) 40 kA
Maximum continuous operating voltage UCPV (General) 800 V DC
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General) 12.5 kA
Screw thread (Protective circuit DC voltage side (DC)) M2
Conductor cross section AWG (Indicator/remote signaling) 14 ... 2
Impulse discharge current (10/350) µs, charge (General) 3.125 As
Stripping length (Protective circuit DC voltage side (DC)) 7 mm
Connection method (Protective circuit DC voltage side (DC)) Screw connection
Flammability rating according to UL 94 (Ambient conditions) V-0
Operating current (Protective circuit DC voltage side (DC)) 5 mA AC ... 1.5 A AC
Operating voltage (Protective circuit DC voltage side (DC)) 5 V AC ... 250 V AC
Tightening torque (Protective circuit DC voltage side (DC)) 0.25 Nm
Switching function (Protective circuit DC voltage side (DC)) PDT contact
Conductor cross section flexible (Indicator/remote signaling) 2.5 mm² ... 35 mm²
Impulse discharge current (10/350) µs, peak value limp (General) 6.25 kA
Impulse discharge current (10/350) µs, specific energy (General) 9.77 kJ/Ω
Installation location of the disconnect device (Ambient conditions) Internal
Conductor cross section AWG (Protective circuit DC voltage side (DC)) 28 ... 16
Conductor cross section solid (Protective circuit DC voltage side (DC)) 0.14 mm² ... 1.5 mm²
Conductor cross section flexible (Protective circuit DC voltage side (DC)) 0.14 mm² ... 1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Indicator/remote signaling) 10 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Indicator/remote signaling) 2.5 mm²

Descrição do produto

Overvoltage/lightning current protection device for isolated and grounded 2-pole photovoltaic direct current systems, for rail mounting, with remote indication contact, temperature-controlled protecti