Horário de atendimento: Segunda a sexta, das 9h às 18h.
VAL-MS-T1/T2 48/12.5/O-FM - VAL-MS-T1/T2 48/12.5/O-FM 2906282 PHOENIX CONTACT Lightning/surge arrester type 1/2
Em estoque Produto em alta

VAL-MS-T1/T2 48/12.5/O-FM

VAL-MS-T1/T2 48/12.5/O-FM 2906282 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00 USD
3574 em estoque
Especificações principais
GTIN: 4055626063072
Note: Made to Order (non-returnable)
Orderkey: 2906282
(General): 160 A AC (gG)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626063072
Note Made to Order (non-returnable)
Orderkey 2906282
(General) 160 A AC (gG)
Catalog page Page 39 (C-4-2017)
Packing unit 12 pc
Country of origin DE (Germany)
(Connection data) (L-) - G
Custom tariff number 85363090
(Ambient conditions) (L+) - PE
(Protective circuit) 30 ... 14 (UL)
Altitude (Dimensions) max. 2000 m
Minimum order quantity 12 pc
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) black
Response time tA (General) ≤ 25 ns
SPD Type (Connection data) 1CA
Depth (Key Commercial Data) 89.2 mm
Width (Key Commercial Data) 17.5 mm
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 77.1 mm
Nominal voltage UN (General) -48 V DC (RRH)
TOV behavior at UT (General) 100 V AC (5 s / withstand mode)
(Indicator/remote signaling) 10 ... 2 (UL)
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 0.6 mA
Shock (operation) (Dimensions) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 80 A
Residual voltage Ures (General) ≤ 0.4 kV (at In)
Response time tA(L-N) (General) ≤ 25 ns
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Nominal voltage (Connection data) 60 V DC
Response time tA(L-PEN) (General) ≤ 25 ns
Screw thread (Protective circuit) M2
TOV behavior at UT(L-N) (General) 100 V AC (5 s / withstand mode)
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
TOV behavior at UT(L-PEN) (General) 100 V AC (5 s / withstand mode)
Mode of protection (Connection data) L-L
Weight per Piece (excluding packing) 154.030 g
Housing material (Ambient conditions) PBT
Stripping length (Protective circuit) 7 mm
Tightening torque (UL specifications) 30 lbf-in.
Voltage protection level Up (General) ≤ 0.4 kV
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Connection method (Protective circuit) Screw connection
Horizontal pitch (Key Commercial Data) 1 Div.
Operating current (Protective circuit) 5 mA AC ... 1.5 A
Operating voltage (Protective circuit) 5 V AC ... 250 V AC
REACh SVHC (Standards and Regulations) Lead 7439-92-1
Standby power consumption PC (General) ≤ 45 mVA
Tightening torque (Protective circuit) 0.25 Nm
Maximum continuous voltage UC (General) 75 V AC
Mode of protection (Ambient conditions) L-PEN
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 1
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) EN 61643-11/A11 2007
Voltage protection level Up(L-N) (General) ≤ 0.4 kV
Power distribution system (Connection data) Single phase
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) DC
IEC test classification (Ambient conditions) I / II
Short-circuit current rating ISCCR (General) 25 kA
Voltage protection level Up(L-PEN) (General) ≤ 0.4 kV
Max. backup fuse with branch wiring (General) 160 A AC (gG)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Screw connection
Nominal discharge current In (Connection data) 20 kA
Tightening torque (Indicator/remote signaling) 3 Nm ... 4.5 Nm (UL)
Conductor cross section AWG (UL specifications) 10 ... 2
Measured limiting voltage MLV (Connection data) 1240 V
Voltage protection rating VPR (Connection data) 400 V
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 12.5 kA
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General) 30 kA
Nominal discharge current In(L-G) (Connection data) 20 kA
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 80 A AC (gG - 16 mm²)
Measured limiting voltage MLV (L-G) (Connection data) 1240 V
Voltage protection rating VPR (L-N) (Connection data) 400 V
Maximum continuous operating voltage UC(L-N) (General) 75 V AC
Nominal discharge current In(8/20) µs (L-N) (General) 12.5 kA
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Impulse discharge current (10/350) µs, charge (General) 6.25 As
Maximum continuous operating voltage UC(L-PEN) (General) 75 V AC
Maximum discharge current Imax(8/20) µs (L-N) (General) 30 kA
Nominal discharge current In(8/20) µs (L-PEN) (General) 12.5 kA
Nominal discharge current In(L+) - (L-) (Connection data) 20 kA
Conductor cross section solid (Indicator/remote signaling) 1.5 mm² ... 35 mm²
Maximum discharge current Imax(8/20) µs (L-PEN) (General) 30 kA
Flammability rating according to UL 94 (Ambient conditions) V0
Maximum continuous operating voltage MCOV (Connection data) 75 V AC
Measured limiting voltage MLV (L+) - (L-) (Connection data) 1230 V
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 25 mm²
Impulse discharge current (10/350) µs (L-N), charge (General) 6.25 As
Impulse discharge current (10/350) µs, peak value limp (General) 12.5 kA
Impulse discharge current (10/350) µs, specific energy (General) 39 kJ/Ω
Maximum continuous operating voltage MCOV (L-G) (Connection data) 75 V AC
Maximum continuous operating voltage MCOV (L-N) (Connection data) 75 V AC
Impulse discharge current (10/350) µs (L-N), specific energy (General) 39 kJ/Ω
Maximum continuous operating voltage MCOV (L+) - (L-) (Connection data) 100 V DC
Maximum continuous operating voltage MCOV (L+/L-) - G (Connection data) 100 V DC
Impulse discharge current (10/350) µs (L-N), peak current value Iimp (General) 12.5 kA

Descrição do produto

Universal pluggable lightning current / surge arrester equipped with varistors for single-phase power supply networks with common N and PE (2-conductor system: L1, PEN), with remote indication contact
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top