Horário de atendimento: Segunda a sexta, das 9h às 18h.
VAL-SEC-T2-2+0-380DC-FM - VAL-SEC-T2-2+0-380DC-FM 2907876 PHOENIX CONTACT Type 2 surge arrester
Em estoque Produto em alta

VAL-SEC-T2-2+0-380DC-FM

VAL-SEC-T2-2+0-380DC-FM 2907876 PHOENIX CONTACT Type 2 surge arrester

$0.00 USD
3078 em estoque
Especificações principais
GTIN: 4055626245010
Note: Made to Order (non-returnable)
Orderkey: 2907876
(General): 10 A (gG / B at ISCCR> 100 A)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626245010
Note Made to Order (non-returnable)
Orderkey 2907876
(General) 10 A (gG / B at ISCCR> 100 A)
Catalog page Page 51 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) (DC-) - G
Custom tariff number 85363030
(Ambient conditions) PBT-FR
(Protective circuit) 1 A DC (30 V DC)
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 6000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) light grey RAL 7035
Response time tA (General) ≤ 25 ns
SPD Type (Connection data) 4CA
Depth (Key Commercial Data) 74.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 25.4 mm
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions) T2
Height (Key Commercial Data) 97.9 mm
Nominal voltage UN (General) 350 V DC ... 400 V DC
TOV behavior at UT (General) 551 V DC (5 s / withstand mode)
Residual current IPE (General) ≤ 350 µA DC
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 40 A (Biconnect M4 fork-type cable lug 6​ mm²)
Degree of protection (Dimensions) IP20
Nominal voltage (Connection data) 400 V DC
Screw thread (Protective circuit) M2
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data) (DC+) - (DC-)
Weight per Piece (excluding packing) 226.600 g
Housing material (Ambient conditions) PA 6.6-FR 20% GF
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Stripping length (Protective circuit) 7 mm
Tightening torque (UL specifications) 4 lbf-in.
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Connection method (Protective circuit) Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data) 1.4 Div.
Operating current (Protective circuit) 5 mA AC ... 1 A AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC (Altitude ≤ 2000 m amsl)
Tightening torque (Protective circuit) 0.25 Nm
Maximum continuous voltage UC (General) 450 V DC
Mode of protection (Ambient conditions) (DC+) - (DC-)
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 2
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) IEC 61643-11 2011
Power distribution system (Connection data) DC
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) DC
IEC test classification (Ambient conditions) II
Short-circuit current rating ISCCR (General) 0.1 kA (without backup fuse)
Max. backup fuse with branch wiring (General) 20 A (gG / B at ISCCR> 200 A)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Fork-type cable lug
Nominal discharge current In (Connection data) 20 kA
Tightening torque (Indicator/remote signaling) 4.5 Nm
Conductor cross section AWG (UL specifications) 30 ... 14
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 20 kA
Tightening torque (UL indicator/remote signaling) 30 lbf-in.
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General) 40 kA
Total discharge current Itotal(8/20) µs (General) 40 kA
Voltage protection level Up(DC+) - (DC-) (General) ≤ 3 kV
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Voltage protection level Up(DC+/DC-) - PE (General) ≤ 1.5 kV
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 20 A (gG / B at ISCCR> 200 A)
Conductor cross section AWG (Indicator/remote signaling) 12 ... 4
Impulse discharge current (10/350) µs, charge (General) 0.5 As
Conductor cross section solid (Indicator/remote signaling) 2.5 mm² ... 25 mm²
Conductor cross section AWG (UL indicator/remote signaling) 10 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 6 mm²
Impulse discharge current (10/350) µs, peak value limp (General) 1 kA
Impulse discharge current (10/350) µs, specific energy (General) 0.25 kJ/Ω

Descrição do produto

Plug-in surge protection device, according to Type 2/Class II, for DC current sources with linear service characteristic, with remote indication contact.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top