Especificações principais
GTIN: 4055626244587
Orderkey: 2907865
(General): 6 kA (for 20 A gG/B backup fuse)
Catalog page: Page 50 (C-4-2017)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626244587
Orderkey 2907865
(General) 6 kA (for 20 A gG/B backup fuse)
Catalog page Page 50 (C-4-2017)
Packing unit 1 pc
Country of origin DE (Germany)
(Connection data) (DC-) - G
Custom tariff number 85363030
(Ambient conditions) PBT-FR
(Protective circuit) 1 A DC (30 V DC)
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 6000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) light grey RAL 7035
Response time tA (General) ≤ 25 ns
SPD Type (Connection data) 1
Depth (Key Commercial Data) 74.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 25.4 mm
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions) T2
Height (Key Commercial Data) 97.9 mm
Nominal voltage UN (General) 48 V DC ... 60 V DC
TOV behavior at UT (General) 87 V DC (5 s / withstand mode)
Residual current IPE (General) ≤ 50 µA DC
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 40 A (Biconnect M4 fork-type cable lug 6​ mm²)
Degree of protection (Dimensions) IP20
Nominal voltage (Connection data) 60 V DC
Screw thread (Protective circuit) M2
Mounting type (Ambient conditions) DIN rail mounting
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data) (DC+) - (DC-)
Weight per Piece (excluding packing) 206.600 g
Housing material (Ambient conditions) PA 6.6-FR 20% GF
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Stripping length (Protective circuit) 7 mm
Tightening torque (UL specifications) 4 lbf-in.
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Connection method (Protective circuit) Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data) 1.4 Div.
Operating current (Protective circuit) 5 mA AC ... 1 A AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC (Altitude ≤ 2000 m amsl)
Tightening torque (Protective circuit) 0.25 Nm
Maximum continuous voltage UC (General) 75 V DC
Mode of protection (Ambient conditions) (DC+) - (DC-)
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 2
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) IEC 61643-11 2011
Power distribution system (Connection data) DC
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) DC
IEC test classification (Ambient conditions) II
Short-circuit current rating ISCCR (General) 0.2 kA (without backup fuse)
Max. backup fuse with branch wiring (General) 20 A (gG / B at ISCCR> 200 A)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Fork-type cable lug
Nominal discharge current In (Connection data) 20 kA
Tightening torque (Indicator/remote signaling) 4.5 Nm
Conductor cross section AWG (UL specifications) 30 ... 14
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 20 kA
Tightening torque (UL indicator/remote signaling) 30 lbf-in.
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General) 40 kA
Total discharge current Itotal(8/20) µs (General) 40 kA
Voltage protection level Up(DC+) - (DC-) (General) ≤ 0.9 kV
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Voltage protection level Up(DC+/DC-) - PE (General) ≤ 0.5 kV
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 20 A (gG / B at ISCCR> 200 A)
Short-circuit current rating (SCCR) (Connection data) 50 kA
Conductor cross section AWG (Indicator/remote signaling) 12 ... 4
Impulse discharge current (10/350) µs, charge (General) 2 As
Voltage protection rating VPR (DC+) - G (Connection data) 400 V
Voltage protection rating VPR (DC-) - G (Connection data) 400 V
Conductor cross section solid (Indicator/remote signaling) 2.5 mm² ... 25 mm²
Conductor cross section AWG (UL indicator/remote signaling) 10 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 6 mm²
Voltage protection rating VPR (DC+) - (DC-) (Connection data) 800 V
Impulse discharge current (10/350) µs, peak value limp (General) 4 kA
Impulse discharge current (10/350) µs, specific energy (General) 4 kJ/Ω

Descrição do produto

Plug-in surge protection device, according to Type 2/Class II, for DC current sources with linear service characteristic, with remote indication contact.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top