Horário de atendimento: Segunda a sexta, das 9h às 18h.
VAL-US-48/65/1+0-FM - VAL-US-48/65/1+0-FM 2910345 PHOENIX CONTACT Type 1/2 surge protection device
Em estoque Produto em alta

VAL-US-48/65/1+0-FM

VAL-US-48/65/1+0-FM 2910345 PHOENIX CONTACT Type 1/2 surge protection device

$0.00 USD
4810 em estoque
Especificações principais
GTIN: 4055626444871
Note: Made to Order (non-returnable)
Orderkey: 2910345
(General): ≤ 0.25 kV (at 3 kA)
Informações do fornecedor
Produtos: 0
Geralmente enviado em 2 a 3 dias úteis.
Qualidade garantida
Envio rápido
Suporte técnico

Especificações técnicas

Parâmetro Valor
GTIN 4055626444871
Note Made to Order (non-returnable)
Orderkey 2910345
(General) ≤ 0.25 kV (at 3 kA)
Packing unit 1 pc
Country of origin US (United States)
Custom tariff number 85363030
(Ambient conditions) PBT
(Protective circuit) 1 A DC (30 V DC)
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) jet black RAL 9005
Response time tA (General) ≤ 25 ns
SPD Type (Connection data) 1
Depth (Key Commercial Data) 65.5 mm
Width (Key Commercial Data) 17.8 mm
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 96.8 mm
Nominal voltage UN (General) 60 V DC ±10 %
TOV behavior at UT (General) 130 V DC (5 s / withstand mode)
(Indicator/remote signaling) 4.5 Nm (25 mm² ... 35 mm²)
Residual current IPE (General) ≤ 0.6 mA
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 80 A
Residual voltage Ures (General) ≤ 0.4 kV (at In)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Nominal voltage (Connection data) 48 V DC
Screw thread (Protective circuit) M2
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data) (DC+) - (DC-)
Weight per Piece (excluding packing) 130.000 g
Housing material (Ambient conditions) PA 6.6
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Stripping length (Protective circuit) 7 mm
Tightening torque (UL specifications) 2 lbf-in. ... 4 lbf-in.
Voltage protection level Up (General) ≤ 0.4 kV
Connection method (Protective circuit) Screw connection
Horizontal pitch (Key Commercial Data) 1 Div.
Operating current (Protective circuit) 5 mA AC ... 1.5 A AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC
Tightening torque (Protective circuit) 0.25 Nm
Maximum continuous voltage UC (General) 100 V DC
Mode of protection (Ambient conditions) (DC+) - (DC-)
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 1
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) IEC 61643-11 2011
Power distribution system (Connection data) DC
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) DC
IEC test classification (Ambient conditions) I / II
Short-circuit current rating ISCCR (General) 5 kA
Max. backup fuse with branch wiring (General) 160 A (gG)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Screw connection
Nominal discharge current In (Connection data) 20 kA
Tightening torque (Indicator/remote signaling) 4.5 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (UL specifications) 30 ... 14
Voltage protection rating VPR (Connection data) 400 V
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 12.5 kA
Maximum Surge Current per Phase (Connection data) 65 kA
Tightening torque (UL indicator/remote signaling) 30 lbf-in.
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General) 12.5 kA
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 80 A (gG)
Short-circuit current rating (SCCR) (Connection data) 5 kA
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Conductor cross section solid (Indicator/remote signaling) 1.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling) 10 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Maximum continuous operating voltage MCOV (Connection data) 100 V DC
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 25 mm²

Descrição do produto

1-channel surge protection device with remote indication contact, for 48 V DC.
Principais características
  • Qualidade de nível industrial
  • Em conformidade com a RoHS
  • Certificado CE
  • Garantia de 1 ano

Documentos do produto

Ficha de dados

Especificações técnicas e dados de desempenho

Manual do Usuário

Guia de instalação e operação

Top